infosec e4
I compile nut with the voltronic-driver on my computer then I've copy the driver "/lib/nut/voltronic_ser" on the server. I can now shutdown the ups using "upscmd -u admin myups shutdown.return". My first question is, is it really ok to only take the driver whithout taking the whole package? I'm using upssched to shutdown server after 15mn on battery, the "shutdown -h +0&quot...
2013 Aug 01
2
infosec e4
On Aug 1, 2013, at 8:15 AM, Charles Lepple wrote: > On Jul 29, 2013, at 7:12 AM, James HORLEY wrote: > >> There?s a software advised by the constructor that work on linux (http://www.power-software-download.com/viewpower.html), unfortunately it?s heavy (tomcat and java) and I don?t find it as flexible as NUT. > > We have a development branch called "voltronic-driver"
2013 Jul 31
2
Fw: infosec e4
...or near unexpected token `CPPUNIT,' ./configure: line 7079: `PKG_CHECK_MODULES(CPPUNIT, cppunit, have_cppunit=yes, have_cppunit=no)' I put in commentary the line PKG_CHECK_MODULES(CPPUNIT, cppunit, have_cppunit=yes, have_cppunit=no) then # make # make installI took the driver voltronic_ser then from my workstation put it in the server, change the ups.conf and try it.The command ?upscmd ?u admin myups shutdown.return? now work (shutting down server then ups).Unfortunately, when I do ?shutdown ?h +0?, the ups is never shut down. After a little research, it appears that the line ?upsmon...
2013 Aug 01
0
infosec e4
...79: `PKG_CHECK_MODULES(CPPUNIT, cppunit, > have_cppunit=yes, have_cppunit=no)' Do you have pkg-config installed? > I put in commentary the line PKG_CHECK_MODULES(CPPUNIT, cppunit, have_cppunit=yes, have_cppunit=no) then > # make > # make install > I took the driver voltronic_ser then from my workstation put it in the server, change the ups.conf and try it. > The command ?upscmd ?u admin myups shutdown.return? now work (shutting down server then ups). > Unfortunately, when I do ?shutdown ?h +0?, the ups is never shut down. After a little research, it appears that the...
2013 Aug 02
2
infosec e4
...9: `PKG_CHECK_MODULES(CPPUNIT, cppunit, > have_cppunit=yes, have_cppunit=no)' Do you have pkg-config installed? > I put in commentary the line PKG_CHECK_MODULES(CPPUNIT, cppunit, > have_cppunit=yes, have_cppunit=no) then > # make > # make install > I took the driver voltronic_ser then from my workstation put it in the > server, change the ups.conf and try it. > The command ?upscmd ?u admin myups shutdown.return? now work (shutting > down server then ups). > Unfortunately, when I do ?shutdown ?h +0?, the ups is never shut down. > After a little research, it...
2013 Aug 26
0
infosec e4
...9: `PKG_CHECK_MODULES(CPPUNIT, cppunit, > have_cppunit=yes, have_cppunit=no)' Do you have pkg-config installed? > I put in commentary the line PKG_CHECK_MODULES(CPPUNIT, cppunit, > have_cppunit=yes, have_cppunit=no) then > # make > # make install > I took the driver voltronic_ser then from my workstation put it in the > server, change the ups.conf and try it. > The command ?upscmd ?u admin myups shutdown.return? now work (shutting > down server then ups). > Unfortunately, when I do ?shutdown ?h +0?, the ups is never shut down. > After a little research, it...