2011 May 17
3
Powercom issues in NUT (was: PowerCom BNT2000AT ups on nut 2.6.0 - second try)
...d APC! > > > > > > [APC1] > > > > > > driver = powercom > > > type = BNT > > > port = /dev/ttyS1 > > > numOfBytesFromUPS = 16 > > > methodOfFlowControl = no_flow_control > > > validationSequence = {{11,0x42},{8,0},{8,0}} > > > shutdownArguments = {{1,30},y} > > > modelname = BNT2000APT > > > serialnumber = 2233445566 > > > desc = Computer Room Small UPS > > > > > > (...) > > > > a powercom patch h...
2007 Dec 29
1
Odd Values For Powercoms
...5,0.1811} driver.parameter.manufacturer: PowerCom driver.parameter.methodOfFlowControl: dtr0rts1 driver.parameter.numOfBytesFromUPS: 16 driver.parameter.pollinterval: 2 driver.parameter.port: /dev/cuaa0 driver.parameter.shutdownArguments: {{0,10},n} driver.parameter.type: KIN2200AP driver.parameter.validationSequence: {{7,0},{8,0},{8,0}} driver.parameter.voltage: {1.9216,-0.0977,0.82857,0.0000} driver.version: 2.2.0 driver.version.internal: $ Revision: 0.5 $ input.frequency: 0.00 input.voltage: 0.0 input.voltage.nominal: 110 output.frequency: 59.53 output.voltage: 14.1 <-- Wierd ups.load: 11.9 ups.mfr: Power...
2011 May 13
1
PowerCom BNT2000AT ups on nut 2.6.0 - second try
...sion is 2.6.36 UPS is PowerCom BNT2000AT "Driver" is powercom ups.conf looks like this! Okay so APC1 is not and APC! [APC1] driver = powercom type = BNT port = /dev/ttyS1 numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{11,0x42},{8,0},{8,0}} shutdownArguments = {{1,30},y} modelname = BNT2000APT serialnumber = 2233445566 desc = Computer Room Small UPS I running /lib/nut/powercom -a APC1 -DDDDDDDDDD (Okay so the debugs are overboard!!!) Result is this! Network UPS Tools - Powe...
2005 Dec 30
2
BNT600AP
Hi, I have a little problem with PowerCom BNT600AP after running driver I see: root@rask> powercom -D /dev/ttyS1 Network UPS Tools - PowerCom and similars protocol UPS driver $ Revision: 0.5 $ (2.0.2) debug level is '1' Values of arguments: manufacturer : 'PowerCom' model name : 'Unknown' serial number : 'Unknown' line
2011 May 09
0
PowerCom BNT2000AT ups on nut 2.6.0
...sion is 2.6.36 UPS is PowerCom BNT2000AT "Driver" is powercom ups.conf looks like this! Okay so APC1 is not and APC! [APC1] driver = powercom type = BNT port = /dev/ttyS1 numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{11,0x42},{8,0},{8,0}} shutdownArguments = {{1,30},y} modelname = BNT2000APT serialnumber = 2233445566 desc = Computer Room Small UPS I running /lib/nut/powercom -a APC1 -DDDDDDDDDD (Okay so the debugs are overboard!!!) Result is this! Network UPS Tools - Powe...