Powercom issues in NUT (was: PowerCom BNT2000AT ups on nut 2.6.0 - second try)
...d APC!
> > >
> > > [APC1]
> > >
> > > driver = powercom
> > > type = BNT
> > > port = /dev/ttyS1
> > > numOfBytesFromUPS = 16
> > > methodOfFlowControl = no_flow_control
> > > validationSequence = {{11,0x42},{8,0},{8,0}}
> > > shutdownArguments = {{1,30},y}
> > > modelname = BNT2000APT
> > > serialnumber = 2233445566
> > > desc = Computer Room Small UPS
> > >
> > > (...)
> >
> > a powercom pat...
2007 Dec 29
1
Odd Values For Powercoms
...5,0.1811}
driver.parameter.manufacturer: PowerCom
driver.parameter.methodOfFlowControl: dtr0rts1
driver.parameter.numOfBytesFromUPS: 16
driver.parameter.pollinterval: 2
driver.parameter.port: /dev/cuaa0
driver.parameter.shutdownArguments: {{0,10},n}
driver.parameter.type: KIN2200AP
driver.parameter.validationSequence: {{7,0},{8,0},{8,0}}
driver.parameter.voltage: {1.9216,-0.0977,0.82857,0.0000}
driver.version: 2.2.0
driver.version.internal: $ Revision: 0.5 $
input.frequency: 0.00
input.voltage: 0.0
input.voltage.nominal: 110
output.frequency: 59.53
output.voltage: 14.1 <-- Wierd
ups.load: 11.9
ups.mfr: P...
2011 May 13
1
PowerCom BNT2000AT ups on nut 2.6.0 - second try
...sion is 2.6.36
UPS is PowerCom BNT2000AT
"Driver" is powercom
ups.conf looks like this! Okay so APC1 is not and APC!
[APC1]
driver = powercom
type = BNT
port = /dev/ttyS1
numOfBytesFromUPS = 16
methodOfFlowControl = no_flow_control
validationSequence = {{11,0x42},{8,0},{8,0}}
shutdownArguments = {{1,30},y}
modelname = BNT2000APT
serialnumber = 2233445566
desc = Computer Room Small UPS
I running /lib/nut/powercom -a APC1 -DDDDDDDDDD (Okay so the debugs are
overboard!!!)
Result is this!
Network UPS Tools -...
2005 Dec 30
2
BNT600AP
Hi,
I have a little problem with PowerCom BNT600AP after running driver I
see: root@rask> powercom -D /dev/ttyS1
Network UPS Tools - PowerCom and similars protocol UPS driver $
Revision: 0.5 $ (2.0.2)
debug level is '1'
Values of arguments:
manufacturer : 'PowerCom'
model name : 'Unknown'
serial number : 'Unknown'
line
2011 May 09
0
PowerCom BNT2000AT ups on nut 2.6.0
...sion is 2.6.36
UPS is PowerCom BNT2000AT
"Driver" is powercom
ups.conf looks like this! Okay so APC1 is not and APC!
[APC1]
driver = powercom
type = BNT
port = /dev/ttyS1
numOfBytesFromUPS = 16
methodOfFlowControl = no_flow_control
validationSequence = {{11,0x42},{8,0},{8,0}}
shutdownArguments = {{1,30},y}
modelname = BNT2000APT
serialnumber = 2233445566
desc = Computer Room Small UPS
I running /lib/nut/powercom -a APC1 -DDDDDDDDDD (Okay so the debugs are
overboard!!!)
Result is this!
Network UPS Tools -...