Displaying 6 results from an estimated 6 matches for "upspowercom".
2017 May 17
2
Fw: [Nut-upsdev] POWERCOM-UPS-USB : UPS Shutdown
Good Day Roger
AA. notice that during the test, you have little or no load, since despite
being in state OB
DISCHRG the battery.charge is still 100. It's best to perform such tests
with a dummy load
such as a table lamp and an old fashioned incandescent 100 watt bulb.
==> Yes. I got it and try to ascend load as below results
dinow-All-Series:~# upsc pcmups
Init SSL without
2017 May 17
0
[Nut-upsdev] POWERCOM-UPS-USB : UPS Shutdown
On May 17, 2017, at 4:53 AM, Dinow Hsieh <dinow at upspowercom.com.tw> wrote:
>
> ==> I tried below set-command but it react fail
>
> dinow-All-Series:~# upsrw -s "ups.delay.shutdown"="30" -u pcmups pcmups at localhost
> Password:
> Unexpected response from upsd: ERR ACCESS-DENIED
>
This error is not from the...
2023 Jan 13
1
battery.voltage Powercom Macan MRT-3000
...h + (Low/100)] : 2.21
? Battery voltage : 2.21 * 6 * 6 = 79.56 Vol (1 package with 6 cells / MRT has 6 packages)
Best regards
Sandy Chang, Powercom Taiwan HQ
-----Original Message-----
From: Alex Rydzewski [mailto:arydzewski at elyland.net]
Sent: Thursday, January 12, 2023 5:47 PM
To:pcm.eu at upspowercom.com
Subject: MRT-3000 USB battery.voltage
Hello!
I have the MRT-3000 UPS and try to get real battery voltage through USB.
USB protocol reference has specify for battery.voltage:
report id | Usage | Usage Name | Data Access | Length
26 0X8430 Battery Voltage R/O...
2017 May 11
2
Good Day NUT
Good Day nut
Many thanks for your reading
==> AA. I confront an issue that can't shutdown the ups
With the nut, I can get the ups status(upsc) and shutdown the linux-ubuntu when power failure occurs(upsmon)
But don't know which configuration I ignore to setup for ups shutdown
==> BB. I want to check that with the command "upsdrvctl shutdown" and
2017 May 17
1
Fw: [Nut-upsdev] POWERCOM-UPS-USB : UPS Shutdown
Good Day Roger
AA. notice that during the test, you have little or no load, since despite
being in state OB
DISCHRG the battery.charge is still 100. It's best to perform such tests
with a dummy load
such as a table lamp and an old fashioned incandescent 100 watt bulb.
==> Yes. I got it and try to ascend load as below results
dinow-All-Series:~# upsc pcmups
Init SSL without
2017 May 16
2
Fw: [Nut-upsdev] POWERCOM-UPS-USB : UPS Shutdown
Good Day Roger Price
AA. Hi, Normally one would expect the UPS to disconnect it's power outlets
after the default ups.delay.shutdown = 20 seconds.
==> I got it. I tried to command "upsdrvctl shutdown" on both line-mode and
battery-mode
==> But ups do not disconnect its outlets power
-----------------------------------------------------------------------------------
BB.