2020 Mar 10
2
Fwd: Windows upssched does not work
...ndows. Upssched is not executed. I have 2 scripts, 1 for notification in upsmon and second for scheduling in upssched. Monitoring is working fine, script write to log. I'm using binary windows installer 2.6.5-6 from NUT. Here are my configs: --- nut.conf MODE=netclient --- upsmon.conf MONITOR ups_1000 at 192.168.3.95 1 <user> <password> slave MINSUPPLIES 1 SHUTDOWNCMD "C:\\WINDOWS\\system32\\shutdown.exe /t 600 /s /d u:6:11" NOTIFYCMD C:\\NUT\\notify.cmd POLLFREQ 5 POLLFREQALERT 5 HOSTSYNC 15 DEADTIME 15 POWERDOWNFLAG C:\\NUT\\killpower NOTIFYMSG ONLINE "UPS %s on l...
2020 Mar 11
1
Fwd: Windows upssched does not work
...s. Upssched is not executed. I > > have 2 scripts, 1 for notification in upsmon and second for scheduling > > in upssched. Monitoring is working fine, script write to log. I'm > > using binary windows installer 2.6.5-6 from NUT. > > > --- upsmon.conf > > MONITOR ups_1000 at 192.168.3.95 1 <user> <password> slave > > MINSUPPLIES 1 > > SHUTDOWNCMD "C:\\WINDOWS\\system32\\shutdown.exe /t 600 /s /d u:6:11" > > NOTIFYCMD C:\\NUT\\notify.cmd > > NOTIFYCMD would normally point to the executable upssched binary. upssched binna...
2014 Nov 09
0
APC Smart-UPS C1500 connected by usb
...t input/output voltages and load for the C 1500 unit. > upsc also reports these values only for model 1000, not for 1500. Battery charge is and runtime are reported. For the 1000, do the values match this page? http://buildbot.networkupstools.org/~buildbot/cayman/docs/latest/ddl/APC/Smart-UPS_1000.html It doesn't look like we have an entry for a C1500 yet. Would you care to submit the output of upsc, upsrw and upscmd -l? > Is this a limitation of the driver, or is there way to get these data? The driver reports values with standard USB HID names. It is possible that your UPS report...
2014 Nov 08
3
APC Smart-UPS C1500 connected by usb
Hi, I have setup NUT in netserver mode on debian wheezy with two APC UPS units connected to it by usb. lsusb identifies the units as Smart-UPS 1000 and Smart-UPS C1500. It appears these do not use the smart protocol and usbhid-ups is the correct driver to use. System: Debian wheezy with stock version of nut (Version: 2.6.4-2.3+deb7u1) Everything works rather well, except that the
2020 Mar 10
0
Fwd: Windows upssched does not work
...oblem with upssched on windows. Upssched is not executed. I > have 2 scripts, 1 for notification in upsmon and second for scheduling > in upssched. Monitoring is working fine, script write to log. I'm > using binary windows installer 2.6.5-6 from NUT. > --- upsmon.conf > MONITOR ups_1000 at 192.168.3.95 1 <user> <password> slave > MINSUPPLIES 1 > SHUTDOWNCMD "C:\\WINDOWS\\system32\\shutdown.exe /t 600 /s /d u:6:11" > NOTIFYCMD C:\\NUT\\notify.cmd NOTIFYCMD would normally point to the executable upssched binary. > --- upssched.conf > CMDSCRIPT...
2010 Nov 07
3
Support of "shutdown.return" on a APC Back-UPS CS 500
Hi all, I am trying to get a APC Back-UPS CS 500 running on my QNAP 419P Nas. Since on all my work I figure out the following: from Network UPS Tools upscmd 2.4.1 [~] # upscmd -l qnapups Instant commands supported on UPS [qnapups]: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.mute - Temporarily mute the UPS beeper beeper.off - Obsolete (use
2014 Nov 10
1
APC Smart-UPS C1500 connected by usb
Hi Charles, Thanks for your response. > For the 1000, do the values match this page? > > > http://buildbot.networkupstools.org/~buildbot/cayman/docs/latest/ddl/APC/Smart-UPS_1000.html > > Yes it does (except that mine is a 120 V model, so input/output voltage is about 125) It doesn't look like we have an entry for a C1500 yet. Would you care to > submit the output of upsc, upsrw and upscmd -l? > Here it is $upscmd -l apc1500 Instant commands supported on...