search for: upping

Displaying 20 results from an estimated 7715 matches for "upping".

2006 Nov 15
1
Tripp Lite OMNI900LCD
I am having an issue running NUT and using an TrippLite OMNI900LCD. When I run ./upsdrvctl start I get : [player@V0002-S002 bin]$./upsdrvctl start Network UPS Tools - UPS driver controller 2.1.0 Network UPS Tools: 0.28 USB communication driver 0.28 - core 0.30 (2.1.0) Detected a UPS: Tripp Lite /TRIPP LITE UPS Using subdriver: TrippLite HID 0.1 (experimental) dstate_setflags: base variable
2005 Aug 26
0
NUT patches
Charles Lepple wrote: > > would you mind forwarding (to either me, or the list) the .txt file > showing the hidparser bug? I am trying to revamp libhid's hidparser, > and it would be helpful to have the descriptor. The text file is contained in the tarball on the patch tracker, at
2005 Aug 29
1
Belkin and newhidups
Hi Peter, I got all your patches and applied them, and I wanted to say kudos for a great job done. This is the output of upsc that I'm getting right now. I had the same issue when using any cvs version (from two weeks ago) that made my UPS go into a state where it wasn't functioning normally (checking the kernel log shows that it cannot be connected and I had around a page of DEVFS_USB
2006 Sep 08
3
newhidups with APC Smart-UPS 1500
Hello, I'm using the stable amd64 port of Debian Linux. I installed (the latest) nut-2.0.1-4 and nut-usb packages for utilizing an APC Smart-UPS 1500 USB. I tried "apcupsd" first but "nut" makes an even more sophisticated impression on me and has more security options. I had problems with the newhidups driver. It didn't find a device with matching VendorID. And
2007 Jan 26
1
newhidups output for Geek Squad GS1285U
This took a long time because I had problems with my system. After I reloaded my operating system several times I found I had a bad memory module. Here is the output from newhidups for my Geek Squad GS1285U. It just kept repeating until I hit ctl-z. I think that this means nut will work for this ups. My computer is not powered by the ups yet. I did not want it to be powered down by accident.
2006 Oct 18
2
newhidups with APC Smart-UPS 1500
I tested your fix (newhidups -DDD /dev/null) using both and APC Back-UPS 350 an APC Smart-UPS RT 2000 XL. No more segmentation fault due to the fixed-size array. ~Jacob -----Original Message----- From: nut-upsdev-bounces@lists.alioth.debian.org [mailto:nut-upsdev-bounces@lists.alioth.debian.org] On Behalf Of Peter Selinger Sent: Monday, October 16, 2006 12:12 PM To: Schmier, Jacob Cc: NUT
2005 Aug 02
0
newhidups for APC Back-UPS ES 650
Gentlemen, Please note that what follows pre-dates the latest changes from Arnaud (just thought someone might want to look at these before I can test the latest!). When running newhidups with -D -D -D I saw messages that looked like errors, and it took me a while to understand that they were not really errors. I therefore added two new entries in apc-hid.h, and I modified a couple of diagnistic
2007 Feb 26
1
Tripp Lite USB UPS
Hello all, About a month ago Peter and Charles were kind enough to try to help me with getting a Tripp Lite USB UPS to work with NUT. I reported quite a bit of initial success, and then other things here fell apart. Between work, fence building and a week-long out of town business trip, I have had to drop this from my list of things to do lately. I am back at it, and I believe I will have
2023 Jan 28
1
nut does not start after reboot
On up-to-date f36, with latest kernel 6.1.7-100.fc36.x86_64. After receiving a few of these messages Broadcast message from nut at e7.eyal.emu.id.au (somewhere) UPS ups at ups is unavailable I noticed and ran sudo systemctl restart nut-driver at ups.service which triggered Broadcast message from nut at e7.eyal.emu.id.au (somewhere) Communications with UPS ups at ups established I now added
2011 Mar 31
2
Cyberpower CP850PFCLCD 120% battery charge
Hello all, I have a CyberPower Systems CP850PFCLCD that I'm hooking up to NUT 2.4.3 from apt running under Ubuntu 10.04. Using the usbhid-ups driver, things *seem* to work at first glance, but there are some odd issues. The most notable issue is that the battery.charge indicator reads 120 when at full charge. I came across this post here:
2006 Nov 11
1
Help with newhidups subdriver for Dynex UPS
Hello everyone! If this message was posted twice, my apologies. I'm having issues with my webmail today... I am using the testing version of NUT from SVN at changeset 582. I have successfully created a stub for newhidups driver for my Dynex DX-800U UPS, but I am completely lost on the customization of it. I've followed the hid-subdrivers.txt instructions and I understand I need to
2005 Jul 22
1
Another HID USB UPS
Gentlemen, I have a new HID USB device, that seems to be quite similar to the currently supported APC HID UPS. I append the dump-tree output, and would much appreciate advice on how to proceed. Certain entries for the current device are not available, but maybe there are some replacements that could be used. This may of course require a new table in apc-hid.h, and I would prefer not to do this
2007 Aug 08
1
Mustek PowerMust 1000AV USB feedbacks
Hello, It looks like the nut-upsuser list is momentarily down. That's why I send it to nut-upsdev list too. I have recently bought a mustek Powermust 1000VA USB (sadly not the USB P version). I have done some tests with the latest nut 2.2.0 megatec and megatec_usb drivers. Here are my feedbacks. It works quite well but is extremely noisy in battery mode (and that is not the noise of the
2007 Aug 08
1
Mustek PowerMust 1000AV USB feedbacks
Hello, It looks like the nut-upsuser list is momentarily down. That's why I send it to nut-upsdev list too. I have recently bought a mustek Powermust 1000VA USB (sadly not the USB P version). I have done some tests with the latest nut 2.2.0 megatec and megatec_usb drivers. Here are my feedbacks. It works quite well but is extremely noisy in battery mode (and that is not the noise of the
2019 Jun 11
2
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
On Jun 10, 2019, at 2:32 PM, Marc Finns wrote: > > Hello, I read all FAQ and other sources but I could not find this situation, so I thought of asking the experts. > I successfully configured a Raspberry NUT server to control my UPS that powers several devices (NUC with ESXI VMs, Synology NAS etc). > All works well in principle, but I have the following behaviours that I could not
2015 Mar 11
0
nutdrv_atcl_usb
2015-03-11 14:21 GMT+01:00 Jakub Scepka <jakub.scepka at gmail.com>: > Would you be so kind and provide some examples (commands), please? > I would run them today in the evening and report back with the logs. First, be sure to have in upsd.users a valid entry to set vars and execute instant commands: [<username>] password = <password> actions = SET instcmds = ALL where
2020 Sep 03
2
UPS reboots with APC UPS
Hello, I have been using NUT for a short period of time and have some questions regarding the UPS reboot signal that I can't figure out. Have tried some googling and reading the DOCs but I am struggling to understand how some variables / things are supposed to work, so would appreciate any help with any of the following questions. I am running NUT on standalone mode on a linux machine
2015 Mar 11
2
nutdrv_atcl_usb
Would you be so kind and provide some examples (commands), please? I would run them today in the evening and report back with the logs. Thank you. Jakub S. On Tue, Mar 10, 2015 at 11:44 PM, hyouko at gmail.com <hyouko at gmail.com> wrote: > mmh.. it looks like someone forgot to hit 'reply all'. > > - relaying the originally attached files (gzipped, minus the two >
2019 Jun 11
0
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
Thanks for the reply. However these two FAQ are unfortunately not describing the situation. - The first issue is that NUT switches off the UPS upon reboot on low battery (not that it dies because of low battery) - The second issue is that the UPS does not recognise being online again (not that the PC does not restart) Sent from my iPhone > On 11 Jun 2019, at 02:03, Charles Lepple <clepple
2018 Jan 16
2
Eaton 5PX after battery replacement still says "replace battery" in NUT
Hi, This might be a simple thing to fix, but I can?t figure it out. We replaced the battery for the first time in our Eaton 5PX a couple of weeks ago, but we haven?t been able to clear the ?ups.alarm: replace battery!? status. Details of our installation are: OS: Debian 6 NUT version: 2.7.4 Installation method: from source tarball UPS device: Eaton 5PX2000IRT, 240V, 1800W, 2000VA, bought in