Displaying 20 results from an estimated 7839 matches for "up".
2006 Nov 15
1
Tripp Lite OMNI900LCD
I am having an issue running NUT and using an TrippLite OMNI900LCD.
When I run ./upsdrvctl start I get :
[player@V0002-S002 bin]$./upsdrvctl start
Network UPS Tools - UPS driver controller 2.1.0
Network UPS Tools: 0.28 USB communication driver 0.28 - core 0.30 (2.1.0)
Detected a UPS: Tripp Lite /TRIPP LITE UPS
Using subdriver: TrippLite HID 0.1 (experimental)
dstate_setflags: b...
2005 Aug 26
0
NUT patches
...e list) the .txt file
> showing the hidparser bug? I am trying to revamp libhid's hidparser,
> and it would be helpful to have the descriptor.
The text file is contained in the tarball on the patch tracker, at
https://alioth.debian.org/tracker/index.php?func=detail&aid=302101&group_id=30602&atid=411544
("Download" at the bottom of the page).
The patch that fixes the parser bug is also contained there - it might
save you some work.
I am appending the textfile below for your ease of access.
> Also useful would be a hex dump of the descriptor itself (availab...
2005 Aug 29
1
Belkin and newhidups
Hi Peter,
I got all your patches and applied them, and I wanted to say kudos for a
great job done.
This is the output of upsc that I'm getting right now.
I had the same issue when using any cvs version (from two weeks ago)
that made my UPS go into a state where it wasn't functioning normally
(checking the kernel log shows that it cannot be connected and I had
around a page of DEVFS_USB errors and some -71 and -...
2006 Sep 08
3
newhidups with APC Smart-UPS 1500
Hello,
I'm using the stable amd64 port of Debian Linux. I installed (the
latest) nut-2.0.1-4 and nut-usb packages for utilizing an APC Smart-UPS
1500 USB. I tried "apcupsd" first but "nut" makes an even more
sophisticated impression on me and has more security options.
I had problems with the newhidups driver. It didn't find a device with
matching VendorID. And hidups crashed.
So I compiled newhidups from latest...
2007 Jan 26
1
newhidups output for Geek Squad GS1285U
This took a long time because I had problems with my system. After I
reloaded my operating system several times I found I had a bad memory
module.
Here is the output from newhidups for my Geek Squad GS1285U. It just
kept repeating until I hit ctl-z. I think that this means nut will work
for this ups. My computer is not powered by the ups yet. I did not want
it to be powered down by accident. When I get to testing it I will use a
dummy load.
gary@redden-p700-610:~/downlo...
2006 Oct 18
2
newhidups with APC Smart-UPS 1500
I tested your fix (newhidups -DDD /dev/null) using both and APC Back-UPS
350 an APC Smart-UPS RT 2000 XL.
No more segmentation fault due to the fixed-size array.
~Jacob
-----Original Message-----
From: nut-upsdev-bounces@lists.alioth.debian.org
[mailto:nut-upsdev-bounces@lists.alioth.debian.org] On Behalf Of Peter
Seling...
2005 Aug 02
0
newhidups for APC Back-UPS ES 650
Gentlemen,
Please note that what follows pre-dates the latest changes from Arnaud
(just thought someone might want to look at these before I can test the
latest!).
When running newhidups with -D -D -D I saw messages that looked like
errors, and it took me a while to understand that they were not really
errors. I therefore added two new entries in apc-hid.h, and I modified
a couple of diagnistic messages in newhidups.c, in the hope that someone
else might have it easier. I append a...
2007 Feb 26
1
Tripp Lite USB UPS
Hello all,
About a month ago Peter and Charles were kind enough to try to help me with
getting a Tripp Lite USB UPS to work with NUT. I reported quite a bit of
initial success, and then other things here fell apart. Between work, fence
building and a week-long out of town business trip, I have had to drop this
from my list of things to do lately. I am back at it, and I believe I will
have time to devote to...
2023 Jan 28
1
nut does not start after reboot
On up-to-date f36, with latest kernel 6.1.7-100.fc36.x86_64.
After receiving a few of these messages
Broadcast message from nut at e7.eyal.emu.id.au (somewhere)
UPS ups at ups is unavailable
I noticed and ran
sudo systemctl restart nut-driver at ups.service
which triggered
Broadcast message from nut...
2011 Mar 31
2
Cyberpower CP850PFCLCD 120% battery charge
Hello all,
I have a CyberPower Systems CP850PFCLCD that I'm hooking up to NUT 2.4.3
from apt running under Ubuntu 10.04. Using the usbhid-ups driver, things
*seem* to work at first glance, but there are some odd issues. The most
notable issue is that the battery.charge indicator reads 120 when at full
charge. I came across this post here:
http://lists.alioth.debian...
2006 Nov 11
1
Help with newhidups subdriver for Dynex UPS
Hello everyone!
If this message was posted twice, my apologies. I'm having issues with my webmail today...
I am using the testing version of NUT from SVN at changeset 582. I have successfully created a stub for newhidups driver for my Dynex DX-800U UPS, but I am completely lost on the customization of it. I've followed the hid-subdrivers.txt instructions and I understand I need to map all the "unmapped.*" lines of my dynex-hid.c to NUT functions. However, I can't make heads or tails of what I...
2005 Jul 22
1
Another HID USB UPS
Gentlemen,
I have a new HID USB device, that seems to be quite similar to the
currently supported APC HID UPS. I append the dump-tree output, and would
much appreciate advice on how to proceed.
Certain entries for the current device are not available, but maybe there
are some replacements that could be used. This may of course require a new
table in apc-hid.h, and I would prefer not to...
2007 Aug 08
1
Mustek PowerMust 1000AV USB feedbacks
Hello,
It looks like the nut-upsuser list is momentarily down. That's why I
send it to nut-upsdev list too.
I have recently bought a mustek Powermust 1000VA USB (sadly not the USB
P version). I have done some tests with the latest nut 2.2.0 megatec and
megatec_usb drivers. Here are my feedbacks.
It works quite well but is e...
2007 Aug 08
1
Mustek PowerMust 1000AV USB feedbacks
Hello,
It looks like the nut-upsuser list is momentarily down. That's why I
send it to nut-upsdev list too.
I have recently bought a mustek Powermust 1000VA USB (sadly not the USB
P version). I have done some tests with the latest nut 2.2.0 megatec and
megatec_usb drivers. Here are my feedbacks.
It works quite well but is e...
2019 Jun 11
2
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
On Jun 10, 2019, at 2:32 PM, Marc Finns wrote:
>
> Hello, I read all FAQ and other sources but I could not find this situation, so I thought of asking the experts.
> I successfully configured a Raspberry NUT server to control my UPS that powers several devices (NUC with ESXI VMs, Synology NAS etc).
> All works well in principle, but I have the following behaviours that I could not find described anywhere.
> • When power returns after the system has shuts down because of battery flat, all restarts immediately. However,...
2015 Mar 11
0
nutdrv_atcl_usb
2015-03-11 14:21 GMT+01:00 Jakub Scepka <jakub.scepka at gmail.com>:
> Would you be so kind and provide some examples (commands), please?
> I would run them today in the evening and report back with the logs.
First, be sure to have in upsd.users a valid entry to set vars and
execute instant commands:
[<username>]
password = <password>
actions = SET
instcmds = ALL
where <username> and <password> are strings of your choice.
Then stop all the NUT-related things already running and (as per
configuration you p...
2020 Sep 03
2
UPS reboots with APC UPS
Hello,
I have been using NUT for a short period of time and have some questions
regarding the UPS reboot signal that I can't figure out. Have tried some
googling and reading the DOCs but I am struggling to understand how some
variables / things are supposed to work, so would appreciate any help
with any of the following questions.
I am running NUT on standalone mode on a linux machine...
2015 Mar 11
2
nutdrv_atcl_usb
...- relaying the originally attached files (gzipped, minus the two
> screenshots, to keep size down).
>
> 2015-03-09 23:20 GMT+01:00 Jakub Scepka (private) <jakub.scepka at gmail.com
> >:
> > Hi everyone!
> >
> > Here is summary for our fellows wit the same/similar UPS to save them 3
> > weeks of life :)
> >
> > First of all I'm running Ubuntu 14.10 (Utopic) on a normal laptop (not
> > VirtualMachine!) and I had to download the source from:
> >
> > https://github.com/zykh/nut/tree/nutdrv_qx-fuji (Thank you Charles)
> &...
2019 Jun 11
0
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
Thanks for the reply. However these two FAQ are unfortunately not describing the situation.
- The first issue is that NUT switches off the UPS upon reboot on low battery (not that it dies because of low battery)
- The second issue is that the UPS does not recognise being online again (not that the PC does not restart)
Sent from my iPhone
> On 11 Jun 2019, at 02:03, Charles Lepple <clepple at gmail.com> wrote:
>
>> On...
2018 Jan 16
2
Eaton 5PX after battery replacement still says "replace battery" in NUT
Hi,
This might be a simple thing to fix, but I can?t figure it out. We replaced the battery for the first time in our Eaton 5PX a couple of weeks ago, but we haven?t been able to clear the ?ups.alarm: replace battery!? status.
Details of our installation are:
OS: Debian 6
NUT version: 2.7.4
Installation method: from source tarball
UPS device: Eaton 5PX2000IRT, 240V, 1800W, 2000VA, bought in October 2013
Here?s the status as repo...