search for: tripplitt

Displaying 3 results from an estimated 3 matches for "tripplitt".

Did you mean: tripplite
2014 Jun 06
0
Question about voltage threshold setting in NUT
...model is Eaton 3S 500. And in windows it has a Eaton Personal Solution Pac. In Battery transfer threshold it has three voltage sensitivity ranges: 96-138, 84-142, 75-144. 96 and 84 are working in NUT, not sure why 75 is not working. Do you think that range is restricted in the firmware? We have a tripplitte model and upsc doesn't have input.transfer.low at all. Please let me know if some other information could be helpful with the NUT. Happy to assist debugging and provide more information. Shen On Thu, Jun 5, 2014 at 9:05 PM, Charles Lepple <clepple at gmail.com> wrote: &gt...
2014 Jun 06
2
Question about voltage threshold setting in NUT
On Jun 5, 2014, at 10:53 PM, Charles Lepple wrote: > As you have seen, the "default.*" and "overwrite.*" names are not actual variables: they are configuration options to change what is returned from upsc. That is why you get VAR-NOT-SUPPORTED. typo; should have been "override.*" -- Charles Lepple clepple at gmail
2006 Aug 25
2
Add USB vendor/device id for Belkin F6C120-UNV
I just moved my UPS over from serial to USB and found that I needed to add it to the hotplug USB list to make things work. Belkin F6C120-UNV - Bus 002 Device 004: ID 050d:0912 Belkin Components It seems to be working OK on 2.0.4 with newhidups. Attached is a patch which I think should add the appropriate device id's in the right places to the trunk code. Jon -------------- next part