2005 Mar 02
4
timing/clock problem
...t when I configure span4 to get clock source from telco they become
unsynchronized. TElco bit rate stays in 2048000 bps, but asterisk stays on
2048443 pbs!!
span=4,1,0,ccs,hdb3,crc4
Telco1 (Intelig) send alarms and I do not sync to then.
I have another PRI circuit used for data connections from Telco2 and I used it
for testing.
Telco2 (Telemar) do not send alarms and I sync to then.
Does anybody have some idea about what is happening?
Regards
[]s
--
Alex G Robertson
NOC - Microlink
2005 Jun 06
3
Asterisk eating up 99.8% cpu
Dear All,
I am using Asterisk CVS-HEAD-05/05/05-15:46:09, and found it using up
99% of cpu 6-8 times in a day, even when its doing nothing or even if it
is, its not supposed to eat all the cpu.
whenever this happens, I need to stop it by issueing "stop now" 15-20
times on CLI or kill the process, then start over.
Please suggest what to do.
regards,
Umair bari
2011 Mar 18
7
One PRI card with 2 (or more) Telcos
Hi list!
We currently have a PRI gateway composed by a box with two Digium quad-span
PRI cards (a TE420 and a ).
One of the cards is filled with TELCO1, while the other has first two slots
filled with TELCO2, and 3rd slot with TELCO3.
I am currently having (timer ?) issues on TELCO3 (span 7)
D-Chan (202 as determined by dahdi_genconf ) is constantly failing causing
on-going calls to terminate.
Problem clears immediately tho. I send a copy of the log with pri debug at a
time of problems...
Is there a...