Displaying 3 results from an estimated 3 matches for "ta705".
2004 Apr 22
2
Adtran TA750 Noise
...ng line, I have no buzz.
I also have 2 Carrier Access Access Bank I's with 12 FXO ports. When I
plug the same analog lines into either one of those, no noise or buzz
whatsoever.
I went so far as to move the TA750 to within 5 feet of the demark and
ran a short CAT5 cable from the demark to the TA705 and still lots of
buzz.
I have duplicates of every part for the TA750's and swapped every
component and cannot get rid of the hum on either unit. I have the power
supply of the Adtran grounded. I am out of ideas :-(.
Any assistance would be greatly appreciated.
Thanks in advance............
2004 Apr 22
0
[SPAM] - Re: Adtran TA750 Noise - Email found in subject
...arrier Access Access Bank I's with 12 FXO ports. When I
> plug the same analog lines into either one of those, no noise or buzz
> whatsoever.
>
>
>
> I went so far as to move the TA750 to within 5 feet of the demark and
> ran a short CAT5 cable from the demark to the TA705 and still lots of
buzz.
>
>
>
> I have duplicates of every part for the TA750's and swapped every
> component and cannot get rid of the hum on either unit. I have the
power
> supply of the Adtran grounded. I am out of ideas L .
>
> Any assistance would be greatly...
2004 Apr 23
0
Adtran TA750 Noise - Email found in subject
...I also have 2 Carrier Access Access Bank Is with 12 FXO ports. When I
plug the same analog
lines into either one of those, no noise or buzz
> whatsoever.
>
>
>
> I went so far as to move the TA750 to within 5 feet of the demark and
ran a short CAT5 cable
from the demark to the TA705 and still lots of buzz.
>
>
>
> I have duplicates of every part for the TA750s and swapped every
component and cannot get rid
of the hum on either unit. I have the power
> supply of the Adtran grounded. I am out of ideas L.
>
> Any assistance would be greatly appreciated....