2012 Apr 10
0
[RFC] Support of ranges of values for writable variables
...lowing network protocol addition: * new RANGE type, for the "GET TYPE" command. This needs the "RW" flag, and completes existing ENUM and STRING types * new "LIST RANGE" command: RANGE ~~~~~ Form: LIST RANGE <upsname> <varname> LIST RANGE su700 input.transfer.low Response: BEGIN LIST RANGE <upsname> <varname> RANGE <upsname> <varname> "<min>" "<max>" ... END LIST RANGE <upsname> <varname> BEGIN LIST RANGE su700 input.transfer.low RANGE su700 inp...
2008 Sep 19
1
APC SmartUPS 750 (SUA750) missing ambient data with usbhid-ups
I have a SmartUPS 750 (SUA750) which has the temperature and humidity SmartSlot card installed. When NUT 2.2 communicates with this UPS over /dev/ttyS0 using apcsmart, using the APC Smart cable connected to the SUA750 serial port, and this ups.conf: [su700] driver=apcsmart port = /dev/ttyS0 I can see the ambient temperature and humidity data with "upsc su700 at localhost". If I switch the driver configuration to use the USB port on the SUA750, disconnect the serial cable, hook up the USB cable, and restart everything usin...
2006 Jul 06
1
NUT localization [was Re: patch file]
On 7/6/06, Arnaud Quette <aquette.dev@gmail.com> wrote: > just in time, since I'm finishing 2.0.4-pre1. > I'll release it tomorrow, and I'll check to include your patch. One more thing: the patch changes the solis driver language to Portuguese. Are these units sold outside of Brazil? At some point, if we start supporting more drivers that are sold regionally, it might be
2013 Jan 29
1
SNMPv3
...ve this in /etc/ups/ups.conf ...... [tfapc01] driver = snmp-ups port = tfapc01.testfest.ixorg.org mibs = apcc snmp_version = v3 secLevel = authPriv secName = tfsnmpprof1 authPassword = ralow6moHet7zoboP8 privPassword = tuseL8Pakaz9degim7 authProtocol=MD5 privProtocol=AES desc = "APC SU700 SNMP v3 device, with the highest security level" ...... Now I test /sbin/snmp-ups -DDD -a tfapc01 Network UPS Tools - Generic SNMP UPS driver 0.68 (2.6.5) 0.000000 debug level is '3' 0.000600 SNMP UPS driver : entering upsdrv_initups() 0.000618 SNMP UPS driver : entering nut_...
2017 Jan 09
2
NUT Client shuts down when performing runtime calibration on APC UPS
...ot all of these may supply power # to the system running upsmon, but if you want to watch it, it has to # be in this section. # # You must have at least one of these declared. # # <system> is a UPS identifier in the form <upsname>@<hostname>[:<port>] # like ups at localhost, su700 at mybox, etc. # # Examples: # # - "su700 at mybox" means a UPS called "su700" on a system called "mybox" # # - "fenton at bigbox:5678" is a UPS called "fenton" on a system called # "bigbox" which runs upsd on port "5678". #...
2014 Oct 14
1
Belkin usp startup
...: ene at coyote:/etc/nut$ sudo grep localhost * hosts.conf:MONITOR myups at localhost "Local UPS" upsd.conf:# This defaults to the localhost listening address and port 3493. You upsd.users:# MONITOR myups at localhost 1 upsmon pass master (or slave) upsmon.conf:# like ups at localhost, su700 at mybox, etc. upsmon.conf:MONITOR myups at localhost 1 gene xxxpassxxxx master upsmon.conf:# MONITOR myups at localhost 1 upsmon pass master (or slave) upssched.conf:# If a specific UPS (myups at localhost) comes back online, then stop the upssched.conf:# AT COMMOK myups at localhost CANCE...
2007 Jun 04
2
APCsmart serial port problem
I have a new APC Smart-UPS SUA2200RM2U. I've had no success with the manufacturer's PowerChute software and smart signaling, so I have decided to try NUT. The smartups driver can't make contact through the serial port. Since this is rack-mounted, it comes with a 940-1524 serial cable. As far as I can tell, this is supposed to work with smart signaling. Here's my ups.conf: