2012 Apr 10
0
[RFC] Support of ranges of values for writable variables
...lowing network protocol addition:
* new RANGE type, for the "GET TYPE" command. This needs the "RW" flag,
and completes existing ENUM and STRING types
* new "LIST RANGE" command:
RANGE
~~~~~
Form:
LIST RANGE <upsname> <varname>
LIST RANGE su700 input.transfer.low
Response:
BEGIN LIST RANGE <upsname> <varname>
RANGE <upsname> <varname> "<min>" "<max>"
...
END LIST RANGE <upsname> <varname>
BEGIN LIST RANGE su700 input.transfer.low
RANGE su700 inp...
2008 Sep 19
1
APC SmartUPS 750 (SUA750) missing ambient data with usbhid-ups
I have a SmartUPS 750 (SUA750) which has the temperature and humidity
SmartSlot card installed. When NUT 2.2 communicates with this UPS over
/dev/ttyS0 using apcsmart, using the APC Smart cable connected to the
SUA750 serial port, and this ups.conf:
[su700]
driver=apcsmart
port = /dev/ttyS0
I can see the ambient temperature and humidity data with "upsc su700 at localhost".
If I switch the driver configuration to use the USB port on the SUA750,
disconnect the serial cable, hook up the USB cable, and restart everything
usin...
2006 Jul 06
1
NUT localization [was Re: patch file]
On 7/6/06, Arnaud Quette <aquette.dev@gmail.com> wrote:
> just in time, since I'm finishing 2.0.4-pre1.
> I'll release it tomorrow, and I'll check to include your patch.
One more thing: the patch changes the solis driver language to
Portuguese. Are these units sold outside of Brazil?
At some point, if we start supporting more drivers that are sold
regionally, it might be
2013 Jan 29
1
SNMPv3
...ve this in /etc/ups/ups.conf
......
[tfapc01]
driver = snmp-ups
port = tfapc01.testfest.ixorg.org
mibs = apcc
snmp_version = v3
secLevel = authPriv
secName = tfsnmpprof1
authPassword = ralow6moHet7zoboP8
privPassword = tuseL8Pakaz9degim7
authProtocol=MD5
privProtocol=AES
desc = "APC SU700 SNMP v3 device, with the highest security level"
......
Now I test
/sbin/snmp-ups -DDD -a tfapc01
Network UPS Tools - Generic SNMP UPS driver 0.68 (2.6.5)
0.000000 debug level is '3'
0.000600 SNMP UPS driver : entering upsdrv_initups()
0.000618 SNMP UPS driver : entering nut_...
2017 Jan 09
2
NUT Client shuts down when performing runtime calibration on APC UPS
...ot all of these may supply power
# to the system running upsmon, but if you want to watch it, it has to
# be in this section.
#
# You must have at least one of these declared.
#
# <system> is a UPS identifier in the form <upsname>@<hostname>[:<port>]
# like ups at localhost, su700 at mybox, etc.
#
# Examples:
#
# - "su700 at mybox" means a UPS called "su700" on a system called "mybox"
#
# - "fenton at bigbox:5678" is a UPS called "fenton" on a system called
# "bigbox" which runs upsd on port "5678".
#...
2014 Oct 14
1
Belkin usp startup
...:
ene at coyote:/etc/nut$ sudo grep localhost *
hosts.conf:MONITOR myups at localhost "Local UPS"
upsd.conf:# This defaults to the localhost listening address and port
3493. You
upsd.users:# MONITOR myups at localhost 1 upsmon pass master (or slave)
upsmon.conf:# like ups at localhost, su700 at mybox, etc.
upsmon.conf:MONITOR myups at localhost 1 gene xxxpassxxxx master
upsmon.conf:# MONITOR myups at localhost 1 upsmon pass master (or slave)
upssched.conf:# If a specific UPS (myups at localhost) comes back online,
then stop the
upssched.conf:# AT COMMOK myups at localhost CANCE...
2007 Jun 04
2
APCsmart serial port problem
I have a new APC Smart-UPS SUA2200RM2U. I've had no success with the
manufacturer's PowerChute software and smart signaling, so I have
decided to try NUT. The smartups driver can't make contact through
the serial port.
Since this is rack-mounted, it comes with a 940-1524 serial cable.
As far as I can tell, this is supposed to work with smart signaling.
Here's my ups.conf: