"More than two wideband layers found. The stream is corrupted." problem
Dear Speex developers,
I am currently experimenting with Speex on Symbian smartphones.
I have compiled the Speex library, and I am now using it in the
following way:
1. Record 320-byte buffers of data in PCM16 format, 8000 Hz sampling rate.
2. Feed the resulting buffer to an instance of a narrowband Speex encoder.
3. Send the encoded data over RTP.
4. Upon receiving on the other side, feed the
2007 Jul 24
0
Shoehorning speex is confusing a newbie
Jean-Marc was correct in that the 16bit value was the culprit for my
encoding woes. after I changed that to a 32 bit value I believe it
encodes correctly, but I really don't have much of any way to know this
absolutely.
I am using the 1.2beta2. I would use the enctest program, I have
looked it over and based a lot of what I am doing on that code but the
project I am developing this on is
2007 Jul 24
0
Shoehorning speex is confusing a newbie
Mike,
Generally "Invalid mode encounterd" == "frames are misaligned"
You should be getting 20 bytes from the encoder each time, and passing 20 bytes to the decoder each time. Is it correct that you have modeled your main loop after testenc-TI-c5x.c?
If you look at encoded silence with a binary editor, you should be able to see the 20-byte repetition pattern. You can also
2007 Jul 24
0
Shoehorning speex is confusing a newbie
I thought I should be getting 20 words because in the windows app the
command line repeats "nbBytes = 20" through the entire decode phase. I
wonder how the frames got misaligned...right now I get 10 words of data
followed by 10 words of 0's which I look at through a memory window in
code composer. now I am pretty sure there is a terminator word that gets
in there so that would make