2014 Jul 29
1
APC protocols and drivers (was: Documenting the NUT driver-qualification process)
...any Smart protocol (the original UPSLink protocol)
>
> But over the years it's been observed that APC has somewhat "fudged" on
> the BackUPS UPSes. Newer ones did appear to implement the UPSlink
> protocol over USB.
>
> Microlink protocol is officially only for APC SmartUPSes. Officially,
> what your supposed to get with a BackUPS is dumb signalling only. But,
> with the newer BackUPSes that have USB output, some seemed to act like
> SmartUPSes even though they were not.
>
> APC has very much blurred the line on the model BN UPSes. These are the
> A...
2014 Jul 26
0
Documenting the NUT driver-qualification process
Hi Eric,
sorry for the lag, summer time...
I'm first seconding Charles comments
2014-07-09 12:31 GMT+02:00 Eric S. Raymond <esr at thyrsus.com>:
> I think the time for me to get involved in NUT documentation has come
> again.
>
welcome back
> Late last week I had to buy a UPS under time pressure. The Eaton unit
> that thus project gifted me with in 2006(?) died
2009 May 04
1
Patches for NUT 2.2.2: APC SmartUPS-900
...elease for your convenience.
> >
> > The mentioned patches are as well a reply for the question asked on the
> > NUT mailing list when somebody asked why an older SmartUPS would not
> > provide the same information as under apcupsd. Simple reason is that
> > the older SmartUPSes (at least mine, SmartUPS-900 w. 7TD firmware) do
> > not respond to the ^Z, a or b commands which are used to inquire what
> > they support.
> >
> >
> > I hope you'll find this useful. Cheers,
> > Thomas Juerges
> >
> >
> > --------...
2014 Jul 09
5
Documenting the NUT driver-qualification process
I think the time for me to get involved in NUT documentation has come
again.
Late last week I had to buy a UPS under time pressure. The Eaton unit
that thus project gifted me with in 2006(?) died during a severe
thunderstorm watch, so it was off to MicroCenter to get a replacement
pronto.
I wound up buying an APC BN700MC. It was what they had in the
performance range I needed. The removable