Displaying 10 results from an estimated 10 matches for "shutdownargu".
2011 May 17
3
Powercom issues in NUT (was: PowerCom BNT2000AT ups on nut 2.6.0 - second try)
...t; > driver = powercom
> > > type = BNT
> > > port = /dev/ttyS1
> > > numOfBytesFromUPS = 16
> > > methodOfFlowControl = no_flow_control
> > > validationSequence = {{11,0x42},{8,0},{8,0}}
> > > shutdownArguments = {{1,30},y}
> > > modelname = BNT2000APT
> > > serialnumber = 2233445566
> > > desc = Computer Room Small UPS
> > >
> > > (...)
> >
> > a powercom patch has recently been submitted, and I had to first discuss
> &...
2006 Aug 18
0
(no subject)
...with UPS connected to the mains:
Network UPS Tools upsd 2.0.4
Connected to UPS [Inform]: powercom-ttyS0
Synchronizing...done
root@marto:/home/marto# upsc Inform@localhost
battery.charge: 108.8
driver.name: powercom
driver.parameter.linevoltage: 220
driver.parameter.port: /dev/ttyS0
driver.parameter.shutdownArguments: {{1,0},y}
driver.parameter.type: Egys
driver.version: 2.0.4
driver.version.internal: $ Revision: 0.5 $
input.frequency: 49.10
input.voltage: 234.3
input.voltage.nominal: 220
output.frequency: 49.10
output.voltage: 234.3
ups.load: 0.7
ups.mfr: PowerCom
ups.model: Unknown
ups.model.type: Egys
u...
2007 Dec 29
1
Odd Values For Powercoms
...parameter.linevoltage: 110
driver.parameter.loadPercentage: {6.1343,-0.3808,1.075,0.1811}
driver.parameter.manufacturer: PowerCom
driver.parameter.methodOfFlowControl: dtr0rts1
driver.parameter.numOfBytesFromUPS: 16
driver.parameter.pollinterval: 2
driver.parameter.port: /dev/cuaa0
driver.parameter.shutdownArguments: {{0,10},n}
driver.parameter.type: KIN2200AP
driver.parameter.validationSequence: {{7,0},{8,0},{8,0}}
driver.parameter.voltage: {1.9216,-0.0977,0.82857,0.0000}
driver.version: 2.2.0
driver.version.internal: $ Revision: 0.5 $
input.frequency: 0.00
input.voltage: 0.0
input.voltage.nominal: 110
o...
2006 Aug 17
1
powercom issues
...> /root/upsLog
sleep 30
control=`/usr/local/ups/bin/upsc Inform@localhost ups.status`
if [ $control != OL ]
then
/usr/local/ups/sbin/upsmon -c fsd
fi
I changed "telinit 0 " to "upsmon -c fsd", following the advice of Mr Selinger from the mailing list. Besides, I added "shutdownArguments={{1,0},y}" to ups.conf, as you advised me. With this configuration, if the system works correctly, according to me things should go like that in case of a prolonged power failure:
power failure->ups.status=="OB"->"upsmon -c fsd"->system shutdown(normal shutdow...
2006 Aug 17
1
powercom upstype identify problem
Mr Claesson,
with my current configuration, the ups.status when the UPS is disconnected from the mains is "OB". There is no more "OB BOOST". Now my upsd.users is:
[root]
password = password
allowfrom = localhost
upsmon master
actions = SET
instcmds = ALL
and upsmon.conf is:
RUN_AS_USER root
MONITOR Inform@localhost 1 root password master
MINSUPPLIES 1
SHUTDOWNCMD
2011 May 13
1
PowerCom BNT2000AT ups on nut 2.6.0 - second try
..." is powercom
ups.conf looks like this! Okay so APC1 is not and APC!
[APC1]
driver = powercom
type = BNT
port = /dev/ttyS1
numOfBytesFromUPS = 16
methodOfFlowControl = no_flow_control
validationSequence = {{11,0x42},{8,0},{8,0}}
shutdownArguments = {{1,30},y}
modelname = BNT2000APT
serialnumber = 2233445566
desc = Computer Room Small UPS
I running /lib/nut/powercom -a APC1 -DDDDDDDDDD (Okay so the debugs are
overboard!!!)
Result is this!
Network UPS Tools - PowerCom protocol UPS driver 0.12 (2.6.0)
0.0000...
2011 Jul 08
2
Ubuntu 10.04 Ultra 700VA UPS Setup Nut
...D UPS Battery] on usb-0000:00:1d.0-1/input0
Here's my etc/nut/ups.conf file:
Code:
# /etc/nut/ups.conf
[Ultra]
driver = powercom
port = port=/dev/hidraw1
linevoltage = 120
manufacturer = Ultra
modelname = ULTRA 700VA
type = Trust
methodOfFlowControl=dtr0rts1
shutdownArguments = {{7,10},y}
Here's what I get when I run sudo upsdrvctl start:
Code:
eric at eric-desktop:~$ sudo upsdrvctl start
Network UPS Tools - UPS driver controller 2.4.3
Network UPS Tools - PowerCom protocol UPS driver 0.12 (2.4.3)
Unable to open port=/dev/hidraw1: No such file or directory...
2005 Dec 30
2
BNT600AP
Hi,
I have a little problem with PowerCom BNT600AP after running driver I
see: root@rask> powercom -D /dev/ttyS1
Network UPS Tools - PowerCom and similars protocol UPS driver $
Revision: 0.5 $ (2.0.2)
debug level is '1'
Values of arguments:
manufacturer : 'PowerCom'
model name : 'Unknown'
serial number : 'Unknown'
line
2011 May 09
0
PowerCom BNT2000AT ups on nut 2.6.0
..." is powercom
ups.conf looks like this! Okay so APC1 is not and APC!
[APC1]
driver = powercom
type = BNT
port = /dev/ttyS1
numOfBytesFromUPS = 16
methodOfFlowControl = no_flow_control
validationSequence = {{11,0x42},{8,0},{8,0}}
shutdownArguments = {{1,30},y}
modelname = BNT2000APT
serialnumber = 2233445566
desc = Computer Room Small UPS
I running /lib/nut/powercom -a APC1 -DDDDDDDDDD (Okay so the debugs are
overboard!!!)
Result is this!
Network UPS Tools - PowerCom protocol UPS driver 0.12 (2.6.0)
0.0000...
2006 Aug 17
2
powercom UPS shoutdown discussion
Thank you for your response.
The point is that I have configured my system to shut down at the event "upsc Inform@localhost ups.status"!="OL", not at "LB". So there will be no /etc/killpower file created. At an ups.status != "OL" event, the following script named "notifyme" is run:
echo `date` >> /root/upsLog
echo " No power, shutting