2011 May 17
3
Powercom issues in NUT (was: PowerCom BNT2000AT ups on nut 2.6.0 - second try)
...t; > driver = powercom > > > type = BNT > > > port = /dev/ttyS1 > > > numOfBytesFromUPS = 16 > > > methodOfFlowControl = no_flow_control > > > validationSequence = {{11,0x42},{8,0},{8,0}} > > > shutdownArguments = {{1,30},y} > > > modelname = BNT2000APT > > > serialnumber = 2233445566 > > > desc = Computer Room Small UPS > > > > > > (...) > > > > a powercom patch has recently been submitted, and I had to first discuss > &...
2006 Aug 18
0
(no subject)
...with UPS connected to the mains: Network UPS Tools upsd 2.0.4 Connected to UPS [Inform]: powercom-ttyS0 Synchronizing...done root@marto:/home/marto# upsc Inform@localhost battery.charge: 108.8 driver.name: powercom driver.parameter.linevoltage: 220 driver.parameter.port: /dev/ttyS0 driver.parameter.shutdownArguments: {{1,0},y} driver.parameter.type: Egys driver.version: 2.0.4 driver.version.internal: $ Revision: 0.5 $ input.frequency: 49.10 input.voltage: 234.3 input.voltage.nominal: 220 output.frequency: 49.10 output.voltage: 234.3 ups.load: 0.7 ups.mfr: PowerCom ups.model: Unknown ups.model.type: Egys u...
2007 Dec 29
1
Odd Values For Powercoms
...parameter.linevoltage: 110 driver.parameter.loadPercentage: {6.1343,-0.3808,1.075,0.1811} driver.parameter.manufacturer: PowerCom driver.parameter.methodOfFlowControl: dtr0rts1 driver.parameter.numOfBytesFromUPS: 16 driver.parameter.pollinterval: 2 driver.parameter.port: /dev/cuaa0 driver.parameter.shutdownArguments: {{0,10},n} driver.parameter.type: KIN2200AP driver.parameter.validationSequence: {{7,0},{8,0},{8,0}} driver.parameter.voltage: {1.9216,-0.0977,0.82857,0.0000} driver.version: 2.2.0 driver.version.internal: $ Revision: 0.5 $ input.frequency: 0.00 input.voltage: 0.0 input.voltage.nominal: 110 o...
2006 Aug 17
1
powercom issues
...> /root/upsLog sleep 30 control=`/usr/local/ups/bin/upsc Inform@localhost ups.status` if [ $control != OL ] then /usr/local/ups/sbin/upsmon -c fsd fi I changed "telinit 0 " to "upsmon -c fsd", following the advice of Mr Selinger from the mailing list. Besides, I added "shutdownArguments={{1,0},y}" to ups.conf, as you advised me. With this configuration, if the system works correctly, according to me things should go like that in case of a prolonged power failure: power failure->ups.status=="OB"->"upsmon -c fsd"->system shutdown(normal shutdow...
2006 Aug 17
1
powercom upstype identify problem
Mr Claesson, with my current configuration, the ups.status when the UPS is disconnected from the mains is "OB". There is no more "OB BOOST". Now my upsd.users is: [root] password = password allowfrom = localhost upsmon master actions = SET instcmds = ALL and upsmon.conf is: RUN_AS_USER root MONITOR Inform@localhost 1 root password master MINSUPPLIES 1 SHUTDOWNCMD
2011 May 13
1
PowerCom BNT2000AT ups on nut 2.6.0 - second try
..." is powercom ups.conf looks like this! Okay so APC1 is not and APC! [APC1] driver = powercom type = BNT port = /dev/ttyS1 numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{11,0x42},{8,0},{8,0}} shutdownArguments = {{1,30},y} modelname = BNT2000APT serialnumber = 2233445566 desc = Computer Room Small UPS I running /lib/nut/powercom -a APC1 -DDDDDDDDDD (Okay so the debugs are overboard!!!) Result is this! Network UPS Tools - PowerCom protocol UPS driver 0.12 (2.6.0) 0.0000...
2011 Jul 08
2
Ubuntu 10.04 Ultra 700VA UPS Setup Nut
...D UPS Battery] on usb-0000:00:1d.0-1/input0 Here's my etc/nut/ups.conf file: Code: # /etc/nut/ups.conf [Ultra] driver = powercom port = port=/dev/hidraw1 linevoltage = 120 manufacturer = Ultra modelname = ULTRA 700VA type = Trust methodOfFlowControl=dtr0rts1 shutdownArguments = {{7,10},y} Here's what I get when I run sudo upsdrvctl start: Code: eric at eric-desktop:~$ sudo upsdrvctl start Network UPS Tools - UPS driver controller 2.4.3 Network UPS Tools - PowerCom protocol UPS driver 0.12 (2.4.3) Unable to open port=/dev/hidraw1: No such file or directory...
2005 Dec 30
2
BNT600AP
Hi, I have a little problem with PowerCom BNT600AP after running driver I see: root@rask> powercom -D /dev/ttyS1 Network UPS Tools - PowerCom and similars protocol UPS driver $ Revision: 0.5 $ (2.0.2) debug level is '1' Values of arguments: manufacturer : 'PowerCom' model name : 'Unknown' serial number : 'Unknown' line
2011 May 09
0
PowerCom BNT2000AT ups on nut 2.6.0
..." is powercom ups.conf looks like this! Okay so APC1 is not and APC! [APC1] driver = powercom type = BNT port = /dev/ttyS1 numOfBytesFromUPS = 16 methodOfFlowControl = no_flow_control validationSequence = {{11,0x42},{8,0},{8,0}} shutdownArguments = {{1,30},y} modelname = BNT2000APT serialnumber = 2233445566 desc = Computer Room Small UPS I running /lib/nut/powercom -a APC1 -DDDDDDDDDD (Okay so the debugs are overboard!!!) Result is this! Network UPS Tools - PowerCom protocol UPS driver 0.12 (2.6.0) 0.0000...
2006 Aug 17
2
powercom UPS shoutdown discussion
Thank you for your response. The point is that I have configured my system to shut down at the event "upsc Inform@localhost ups.status"!="OL", not at "LB". So there will be no /etc/killpower file created. At an ups.status != "OL" event, the following script named "notifyme" is run: echo `date` >> /root/upsLog echo " No power, shutting