Displaying 6 results from an estimated 6 matches for "sendpac".
Did you mean:
sendmac
2010 Mar 16
1
NUT megatec driver tunning
...xecute command. My UPS stupid
> after 'C' and not accept immediately next command on 'upsdrv_initinfo'
> procedure.
> I strongly recommend to add its.
> ________________________________________________
>
> I think line:
>
> send_pace = CLAMP(atoi(getval("sendpace")), 1, 1000) * 1000;
> need replaced by
> send_pace = CLAMP(atoi(getval("sendpace")), 0, 1000) * 1000;
>
> Why limiting minimal value to 1 millisecond ? I recommend to allow set
> 'send_pace' to ZERO if set ' sendpace=0' in config file 'ups.conf...
2015 Jun 12
2
C5 : Firefox 38 bug
On 06/12/2015 02:16 PM, Always Learning wrote:
> On Sat, 2015-06-13 at 12:40 -0600, jd1008 wrote:
>
>> You can also try adblock edge which circimvents the bribe :)
> :-(
>
> https://addons.mozilla.org/en-us/firefox/addon/adblock-edge/
>
>
> **This addon has been discontinued**
>
>
Weird!!!!
I just installed it yesterday. See image of my screen at
2015 Jun 12
0
C5 : Firefox 38 bug
...dblock-edge/
> >
> >
> > **This addon has been discontinued**
> >
> >
> Weird!!!!
> I just installed it yesterday. See image of my screen at
> https://www.sendspace.com/file/udk055
We were not looking at the identical sites. I looked at Mozilla. You
looked at sendpace.com
--
Regards,
Paul.
England, EU. England's place is in the European Union.
2008 Dec 06
0
Some changes to megatec
Hi,
It took a while, but I've finally cleared my pending queue for the
megatec driver and the result is the following set of patches. The
changes are minor, just a couple of models to the compatibility list
and a new parameter "sendpace" so that a user can change the default
interval between command characters (which seems to be needed by at
least one model).
It builds, but I'm unable to test these changes with real hardware,
like I've mentioned before.
With this I'm officially no longer the maintainer fo...
2009 Oct 27
1
Protocol for Ritmo AS-800VA
...een running it on my server for the last week or so with no probs -
so the ritmo code is ok.
Other notes:
1) The unit requires rts to be set high, and is also slower than the
megatec units, so my corresponding ups.conf entry is:
[Ritmo800]
driver = megatec
port = /dev/ttyS0
sendpace = 300
dtr = 1
rts = 1
battvolts=160:195
2) The critically low battery flag turns on quite late - so there isn't
really enough time to switch off a pc when this turns on - however the
battery itself lasts as long as you would expect from any other 800VA UPS.
Let me kno...
2009 May 05
2
Need help identifying UPS for use with NUT
Hi there.
I bought a generic UPS from a local (South African) hardware company,
Sahara. They call it an "Electra 1000 Plus". From what I am told it is a
1000 VA line interactive UPS. It comes with "WinPower" Java based software
that I couldn't get to work. (Crashes on start-up, without any explanation.)
I would like to know if any one on this mailing list could help me