Displaying 2 results from an estimated 2 matches for "r2984".
Did you mean:
2984
2011 Apr 28
2
PowerCOM Driver Update
I and several other users have encountered problems using PowerCOM UPS of
the BNT 1500A model. Looking over other responses and dealing with my own
issues, I submit the following attached patch.
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.alioth.debian.org/pipermail/nut-upsdev/attachments/20110428/00d7d2f9/attachment.htm>
-------------- next
2011 May 17
3
Powercom issues in NUT (was: PowerCom BNT2000AT ups on nut 2.6.0 - second try)
...and make then
> make
> install. No probs!
>
> I tested the update driver and the result was still a validation error!
> This is the console debug output!
>
> gatekeeper nut # /lib/nut/powercom -a APC1 -DDDDDDDDDDNetwork UPS Tools -
> PowerCom protocol UPS driver 0.13 (2.6.0-r2984)
> 0.000000 debug level is '10'
> 0.002388 Flow control disable
> 0.002561 Num of bytes requested for reading from UPS: 16
> 0.148057 Num of bytes received from UPS: 16
> Raw data from UPS:
> 0 0x10 ( )
> 1 0x64 (d)
> 2 0x68 (h)
> 3 0...