search for: queue_if_no_path

Displaying 20 results from an estimated 24 matches for "queue_if_no_path".

2017 Dec 19
0
kernel: blk_cloned_rq_check_limits: over max segments limit., Device Mapper Multipath, iBFT, iSCSI COMSTAR
...e-Mapper Multipath Device Controller... Dec 18 12:46:41 lemans systemd: Started Availability of block devices. Dec 18 12:46:41 lemans systemd: Started Device-Mapper Multipath Device Controller. Dec 18 12:46:41 lemans multipathd: 3600144f00000000000005a2769c70001: load table [0 209715200 multipath 1 queue_if_no_path 0 1 1 service-time 0 5 1 8:64 1 8:144 1 8:48 1 8:160 1 8:0 1] Dec 18 12:46:41 lemans multipathd: 3600144f0000000000000524a93b80002: load table [0 41943040 multipath 1 queue_if_no_path 0 1 1 service-time 0 5 1 8:80 1 8:176 1 8:96 1 8:192 1 8:16 1] Dec 18 12:46:41 lemans multipathd: 3600144f000000000...
2011 Jul 14
1
mount.ocfs2: Invalid argument while mounting /dev/mapper/xenconfig_part1 on /etc/xen/vm/. Check 'dmesg' for more information on this error.
..."true"/> </meta_attributes> </clone> </resources> And all the resource are up and running 3)Then, using my SAN, I've configured multipath as following: xenconfig (3600a0b8000754c84000002a04e031e5a) dm-0 IBM,1726-4xx FAStT size=19G features='1 queue_if_no_path' hwhandler='1 rdac' wp=rw |-+- policy='round-robin 0' prio=3 status=active | |- 3:0:1:0 sdd 8:48 active ready running | `- 4:0:1:0 sdh 8:112 active ready running `-+- policy='round-robin 0' prio=0 status=enabled |- 3:0:0:0 sdb 8:16 active ghost running `- 4:0:0:0 s...
2008 Sep 29
3
LVM related bug in the GPL PV drivers for Windows?
...0.9.10, were OK on XP too. The disk is a multipath LVM volume with four FibreChannel paths to a volume on a Sun Storagetek 6140 storage: carrier3:~ # multipathd -k multipathd> show topology ... ... ... vw-storman2 (3600a0b80004807f80000091248da00ef) dm-0 SUN ,CSM200_R [size=20G][features=1 queue_if_no_path][hwhandler=0] \_ round-robin 0 [prio=6][active] \_ 3:0:1:19 sdcc 69:0 [active][ready] \_ 1:0:0:19 sdag 66:0 [active][ready] \_ round-robin 0 [prio=0][enabled] \_ 1:0:1:19 sdbi 67:192 [active][ghost] \_ 3:0:0:19 sdbh 67:176 [active][ghost] ... ... ... multipathd> A Linux fdisk command in t...
2015 Feb 04
0
multipathd
...ng the IBM's RDAC driver (true) and we were advised to change to using Linux multipath. I've done that but the default configuration for the DS3400s is: device { vendor IBM product 1726-4xx path_checker rdac features 1 queue_if_no_path hardware_handler 1 rdac prio_callout /sbin/mpath_prio_rdac /dev/%n no_path_retry 300 rr_min_io 1000 } The V3700 is still complaining and I note the "path checker rdac" and mpath_prio_rdac lines. Is this rdac the same...
2015 Feb 04
0
multipathd
...for the DS3400s So you switched from IBM's proprietary multipath driver to the native Linux multipathing. Correct? > is: > device { > vendor IBM > product 1726-4xx > path_checker rdac > features 1 queue_if_no_path > hardware_handler 1 rdac > prio_callout /sbin/mpath_prio_rdac /dev/%n > no_path_retry 300 > rr_min_io 1000 > } The right settings are documented here: https://access.redhat.com/solutions/85223 Yoi should...
2015 Feb 04
0
multipathd
...ng the IBM's RDAC driver (true) and we were advised to change to using Linux multipath. I've done that but the default configuration for the DS3400s is: device { vendor IBM product 1726-4xx path_checker rdac features 1 queue_if_no_path hardware_handler 1 rdac prio_callout /sbin/mpath_prio_rdac /dev/%n no_path_retry 300 rr_min_io 1000 } The V3700 is still complaining and I note the "path checker rdac" and mpath_prio_rdac lines. Is this rdac the same...
2015 Feb 04
0
multipathd
...ng the IBM's RDAC driver (true) and we were advised to change to using Linux multipath. I've done that but the default configuration for the DS3400s is: device { vendor IBM product 1726-4xx path_checker rdac features 1 queue_if_no_path hardware_handler 1 rdac prio_callout /sbin/mpath_prio_rdac /dev/%n no_path_retry 300 rr_min_io 1000 } The V3700 is still complaining and I note the "path checker rdac" and mpath_prio_rdac lines. Is this rdac the same...
2015 Feb 04
0
multipathd
...ng the IBM's RDAC driver (true) and we were advised to change to using Linux multipath. I've done that but the default configuration for the DS3400s is: device { vendor IBM product 1726-4xx path_checker rdac features 1 queue_if_no_path hardware_handler 1 rdac prio_callout /sbin/mpath_prio_rdac /dev/%n no_path_retry 300 rr_min_io 1000 } The V3700 is still complaining and I note the "path checker rdac" and mpath_prio_rdac lines. Is this rdac the same...
2015 Feb 04
0
multipathd
...ng the IBM's RDAC driver (true) and we were advised to change to using Linux multipath. I've done that but the default configuration for the DS3400s is: device { vendor IBM product 1726-4xx path_checker rdac features 1 queue_if_no_path hardware_handler 1 rdac prio_callout /sbin/mpath_prio_rdac /dev/%n no_path_retry 300 rr_min_io 1000 } The V3700 is still complaining and I note the "path checker rdac" and mpath_prio_rdac lines. Is this rdac the same...
2015 Feb 04
0
multipathd
...ng the IBM's RDAC driver (true) and we were advised to change to using Linux multipath. I've done that but the default configuration for the DS3400s is: device { vendor IBM product 1726-4xx path_checker rdac features 1 queue_if_no_path hardware_handler 1 rdac prio_callout /sbin/mpath_prio_rdac /dev/%n no_path_retry 300 rr_min_io 1000 } The V3700 is still complaining and I note the "path checker rdac" and mpath_prio_rdac lines. Is this rdac the same...
2010 Jun 03
0
SUN Storage 7310 with RHEL 5.5 / Centos 5.5 and multipathed root, again.
...has two storage heads, H1 and H2, which are in a active/passive configuration. If I define a LUN on H1, everything works great. I edit multipath.conf, re-create the initrd and I find 8 paths with active/ready and active/ghost: mpath0 (3600...0001) dm-0 SUN,Sun Storage 7310 [size=50G][features=1 queue_if_no_path][hwhandler=0][rw] \_ round-robin 0 [prio=200][active] \_ 0:0:0:0 sda 8:0 [active][ready] \_ 0:0:1:0 sdd 8:48 [active][ready] \_ 1:0:0:0 sdg 8:96 [active][ready] \_ 1:0:1:0 sdj 8:144 [active][ready] \_ round-robin 0 [prio=4][enabled] \_ 1:0:2:0 sdm 8:192 [active][ghost] \_ 0:0:2:0 sdn 8:20...
2013 Oct 08
0
CentOS 6.4: Warning! Received an indication that the LUN assignments on this target have changed. The Linux SCSI layer does not automatically remap LUN assignments.
...l6.x86_64 ~> sudo cat /etc/multipath.conf multipaths { multipath { wwid <redacted> alias <redacted> } } defaults { find_multipaths yes user_friendly_names yes } ~> sudo multipath -ll <redacted> (<redacted>) dm-1 HP,P2000G3 FC/iSCSI size=1.3T features='1 queue_if_no_path' hwhandler='0' wp=rw |-+- policy='round-robin 0' prio=130 status=active | |- 2:0:0:12 sdd 8:48 active ready running | `- 1:0:0:12 sdb 8:16 active ready running `-+- policy='round-robin 0' prio=10 status=enabled |- 1:0:1:12 sdc 8:32 active ready running `- 2:0:1:12 sd...
2015 Feb 05
0
UC multipathd
...>Linux multipathing. Correct? Yes. We were told to do so by the suppliers of the V3700. > >> is: >> device { >> vendor IBM >> product 1726-4xx >> path_checker rdac >> features 1 queue_if_no_path >> hardware_handler 1 rdac >> prio_callout /sbin/mpath_prio_rdac /dev/%n >> no_path_retry 300 >> rr_min_io 1000 >> } > >The right settings are documented here: > >https://access.re...
2015 Feb 05
0
UC multipathd
...>Linux multipathing. Correct? Yes. We were told to do so by the suppliers of the V3700. > >> is: >> device { >> vendor IBM >> product 1726-4xx >> path_checker rdac >> features 1 queue_if_no_path >> hardware_handler 1 rdac >> prio_callout /sbin/mpath_prio_rdac /dev/%n >> no_path_retry 300 >> rr_min_io 1000 >> } > >The right settings are documented here: > >https://access.re...
2015 Feb 05
0
UC multipathd
...>Linux multipathing. Correct? Yes. We were told to do so by the suppliers of the V3700. > >> is: >> device { >> vendor IBM >> product 1726-4xx >> path_checker rdac >> features 1 queue_if_no_path >> hardware_handler 1 rdac >> prio_callout /sbin/mpath_prio_rdac /dev/%n >> no_path_retry 300 >> rr_min_io 1000 >> } > >The right settings are documented here: > >https://access.re...
2015 Feb 05
0
UC multipathd
...>Linux multipathing. Correct? Yes. We were told to do so by the suppliers of the V3700. > >> is: >> device { >> vendor IBM >> product 1726-4xx >> path_checker rdac >> features 1 queue_if_no_path >> hardware_handler 1 rdac >> prio_callout /sbin/mpath_prio_rdac /dev/%n >> no_path_retry 300 >> rr_min_io 1000 >> } > >The right settings are documented here: > >https://access.re...
2015 Feb 05
0
UC multipathd
...>Linux multipathing. Correct? Yes. We were told to do so by the suppliers of the V3700. > >> is: >> device { >> vendor IBM >> product 1726-4xx >> path_checker rdac >> features 1 queue_if_no_path >> hardware_handler 1 rdac >> prio_callout /sbin/mpath_prio_rdac /dev/%n >> no_path_retry 300 >> rr_min_io 1000 >> } > >The right settings are documented here: > >https://access.re...
2015 Feb 05
0
UC multipathd
...>Linux multipathing. Correct? Yes. We were told to do so by the suppliers of the V3700. > >> is: >> device { >> vendor IBM >> product 1726-4xx >> path_checker rdac >> features 1 queue_if_no_path >> hardware_handler 1 rdac >> prio_callout /sbin/mpath_prio_rdac /dev/%n >> no_path_retry 300 >> rr_min_io 1000 >> } > >The right settings are documented here: > >https://access.re...
2013 Sep 18
3
multipathing XCP 1.6
Hello, I hope to be in the right list. my question is the following. I can''t seem to get multipathing configure on XCP 1.6. In XenCenter I was able to enable "Multipath" however, in the LUN under general tab I see " multipath 1 of 1 active", the the CLI I do the following command xe --m node session it list only one session. Can someone help me please? Thanks in
2013 Nov 07
1
IBM Storwize V3700 storage - device names
Hello, I have IBM Storwize V3700 storage, connected to 2 IBM x3550 M4 servers via fiber channel. The servers are with QLogic ISP2532-based 8Gb Fibre Channel to PCI Express HBA cards and run Centos 5.10 When I export a volume to the servers, each of them sees the volume twice, i.e /dev/sdb and /dev/sdc, with the same size. Previously I have installed many systems with IBM DS3500 series of