Displaying 5 results from an estimated 5 matches for "princemodey".
2024 Sep 08
0
Nut-upsuser Digest, Vol 231, Issue 4
...wer
was what causing my UPS to shut itself down after a period of time
i really don't know if deleting POWERDOWNFLAG was the right choice or not but if there is anything i can do to properly fix it please let me know
________________________________
From: Nut-upsuser <nut-upsuser-bounces+princemodey=hotmail.com at alioth-lists.debian.net> on behalf of nut-upsuser-request at alioth-lists.debian.net <nut-upsuser-request at alioth-lists.debian.net>
Sent: Sunday, September 8, 2024 2:00 PM
To: nut-upsuser at alioth-lists.debian.net <nut-upsuser at alioth-lists.debian.net>
Subject: Nu...
2024 Sep 08
0
Nut-upsuser Digest, Vol 231, Issue 2
...there is a build of NUT for Windows, so your
gaming PC could run an `upsmon` client for its own shutdowns (listening to
OMV for UPS state info), it seems at the moment it does not. Let's not
complicate things for now :)
Hope this helps,
Jim Klimov
On Sun, Sep 8, 2024, 02:28 Mega DooOooM <princemodey at hotmail.com> wrote:
> No only Server PC is connected to my UPS with USB and the only PC with NUT
>
> as i told Mr.Roger
> POWERDOWNFLAG /etc/killpower
>
> this line might be the culprit it kills my UPS after it shuts down my
> SERVER after 300 seconds
> in the documen...
2024 Sep 07
2
Nut-upsuser Digest, Vol 231, Issue 2
...TIFYFLAG COMMBAD SYSLOG+WALL+EXEC
NOTIFYFLAG SHUTDOWN SYSLOG+WALL+EXEC
NOTIFYFLAG REPLBATT SYSLOG+WALL+EXEC
NOTIFYFLAG NOCOMM SYSLOG+WALL+EXEC
NOTIFYFLAG FSD SYSLOG+WALL+EXEC
RBWARNTIME 43200
NOCOMMWARNTIME 300
FINALDELAY 5
________________________________
From: Nut-upsuser <nut-upsuser-bounces+princemodey=hotmail.com at alioth-lists.debian.net> on behalf of nut-upsuser-request at alioth-lists.debian.net <nut-upsuser-request at alioth-lists.debian.net>
Sent: Saturday, September 7, 2024 2:00 PM
To: nut-upsuser at alioth-lists.debian.net <nut-upsuser at alioth-lists.debian.net>
Subject:...
2024 Sep 06
0
Nut-upsuser Digest, Vol 231, Issue 1
...39;s Topics:
>
>    1. NUT shutsdown my UPS after a period of time even when power
>       is back (Mega DooOooM)
>
>
> ----------------------------------------------------------------------
>
> Message: 1
> Date: Fri, 6 Sep 2024 12:53:19 +0000
> From: Mega DooOooM <princemodey at hotmail.com>
> To: "nut-upsuser at alioth-lists.debian.net"
>         <nut-upsuser at alioth-lists.debian.net>
> Subject: [Nut-upsuser] NUT shutsdown my UPS after a period of time
>         even when power is back
> Message-ID:
>         <
> GV2PR02MB88...
2024 Sep 06
2
NUT shutsdown my UPS after a period of time even when power is back
OS: Openmediavault 7.4.7-1
NUT version: 7.0.4-1
Intalled from OMV plugin installer
MY UPS: APC BX1200MI-GR
connected through USB
all of my UPS data are in this screenshot
my problem that i need help with is as follow:
so what's happening is if my gaming PC / router / switch are connected and power is down
the UPS switches normally without issues from AC to battery and vice versa when the