search for: powstatd

Displaying 2 results from an estimated 2 matches for "powstatd".

Did you mean: powstat
2008 Mar 14
0
Sola 305 with INT-0051 cable
...ial and is communicating properly (after making a very small modification to the source (inserting a usleep)). After verifying that the connection was okay, I hunted around on the net and found the following document: http://ftp.nluug.nl/os/Linux/distr/smeserver/contribs/rmitchell/smeserver/howto/powstatd HOWTO for sme server.htm It indicates that the settings to use when connected via a INT-0025C are: init0 dsr init0 rng init0 dtr init1 rts fail cts,0 low dcd,0 kill dtr,1 This seems to agree with the definition of type 7 in genericups.h: /* Type 7 */ { "CyberPower", "Power99&qu...
2005 Nov 30
4
ups.conf configure
Hello, I got this information from the manufacturer of my ups Kobian/Mercury and were tested wtih powstatd on Linux (Works OK). Now i want to configure it with NUT and i didn't have any luck (it always says OB) Initiliasation for monitoring: RTS = 1 (High) Main power fail: CTS = 0 (Low) Batter low: DCD = 0 (Low) Kill UPS: DTR = 0 (Low) How would the ups.conf look like? Reagards, Lep pozdrav, Ma...