2008 Mar 14
0
Sola 305 with INT-0051 cable
...ial and is communicating
properly (after making a very small modification to the source
(inserting a usleep)). After verifying that the connection was okay, I
hunted around on the net and found the following document:
http://ftp.nluug.nl/os/Linux/distr/smeserver/contribs/rmitchell/smeserver/howto/powstatd HOWTO for sme server.htm
It indicates that the settings to use when connected via a INT-0025C
are:
init0 dsr init0 rng init0 dtr init1 rts fail cts,0 low dcd,0 kill dtr,1
This seems to agree with the definition of type 7 in genericups.h:
/* Type 7 */
{ "CyberPower",
"Power99&qu...
2005 Nov 30
4
ups.conf configure
Hello, I got this information from the manufacturer of my ups Kobian/Mercury
and were tested wtih powstatd on Linux (Works OK). Now i want to configure
it with NUT and i didn't have any luck (it always says OB)
Initiliasation for monitoring: RTS = 1 (High)
Main power fail: CTS = 0 (Low)
Batter low: DCD = 0 (Low)
Kill UPS: DTR = 0 (Low)
How would the ups.conf look like?
Reagards,
Lep pozdrav,