2008 Dec 01
2
dhclient doing DISCOVER with bad IP checksum - bge
...er is refusing to answer the DISCOVER request, as it thinks the IP checksum is wrong, which tcpdump also confirms. Other DHCP clients are working fine on this network, so I do not believe it to be the network, server or dhcpd. Server is running a 2 Port Intel card - em driver. Client is a Dell PE1750 with 2 onboard NIC's - bge driver. I have tried turning off both RXCSUM and TXCSUM on both the client and server machines with no luck. I also tried the second NIC on the server with the same result. This setup was working just a couple of weeks ago, and the only thing that has changed is...
2007 Nov 15
5
IO causing major performance issues
...riences are WRT systems becoming unresponsive (unable to ssh in, etc) for brief periods of time when a large amount of IO is being performed. It's really starting to cause a problem for us. We're on Dell PowerEdge 1955 blades - but this same issue has caused us problems on PE1950, PE1850, PE1750 servers. We're running Centos 4.5 right now. I know Centos 5 includes ionice, more io scheduler/elevator selections like deadlock/etc. Perhaps that would fix this issue. We're running the latest PERC firmware. The specific issue I'm referring to at this point is on a system running m...
2005 Jul 29
1
UNDI - Rom-O-Matic -- A bit off topic..
...a Server is located on a different subnet from the PowerEdge 1650 data transfer fail's, Some of the files are corrupt after transfer. However if the Samba Server is locater on the same subnet, it works just fine. The customer has this same problem with several PE 1650, while other systems like PE1750 and 1850 has no problems. Now to my questions: - How does the UNDI work? - I belive: the PXE boot code in the BIOS configures the NIC to be in "UNDI mode"? - Does a Rom-O-Matic created Boot Floppy also set the NIC in "UNDI mode" as well? (If not, any other option?)...
2005 Apr 12
6
Centos-4 Kernel pannic
...l console to the server and captured the output in order to have a record of what happens. I've included the error messages from the last time it locked up... but it doesn't really mean much to me. Anybody have any ideas what might be causing this server lock up? Server description: -Dell PE1750 - dual 2.8Ghz Xeon (with Hyper Threading on) - 2GB DDR RAM - Perc4-DI onboard RAID using 3 scsi drives in raid-5 configuration -ext3 file system -kernel-smp-2.6.9-5.0.3.EL -mysql - from distribution -2 postfix instances rebuilt with MySQL support -amavisd-new -clamav -spamassassin -rbldnsd -bind...
2006 Apr 03
0
[amr] raid config went from RAID5 to RAID0 ?
I just noticed something very strange on one of our Dell PE1750 servers. It is running FreeBSD 4-STABLE on dual CPU's with the embedded Dell Raid controller (amr driver). Attached are 3 disks of 145GB. On a RAID5 logical drive this gives me ~280GB storage. Up until the last reboot (35 days ago) the 'amrcontrol' status utility gave me: Logical drive...