search for: pdmarkmiss

Displaying 3 results from an estimated 3 matches for "pdmarkmiss".

2017 Jan 21
1
CentOS 7 and Areca ARC-1883I SAS controller: JBOD or not to JBOD?
.... > > Before you pull a drive it's a good idea to properly prepare it for > removal > after confirming that it's OK to remove it. > > Here are a few commands: > > OFFLINE A DISK > MegaCli -PDOffline -PhysDrv[32:0] -a0 > > MARK A DISK AS MISSING > MegaCli -pdmarkmissing -physdrv[32:0] -a0 > > MARK A DISK AS PREPARED FOR REMOVAL > MegaCli -pdprprmv -physdrv[32:0] -a0 > > Here are some easy overview commands that I run when first looking at the > storage on a system: > MegaCli -AdpAllInfo -aAll |grep -A 8 "Device Present"; > Mega...
2017 Jan 21
0
CentOS 7 and Areca ARC-1883I SAS controller: JBOD or not to JBOD?
...osure, the adapter and the virtual disks (logical disks). Before you pull a drive it's a good idea to properly prepare it for removal after confirming that it's OK to remove it. Here are a few commands: OFFLINE A DISK MegaCli -PDOffline -PhysDrv[32:0] -a0 MARK A DISK AS MISSING MegaCli -pdmarkmissing -physdrv[32:0] -a0 MARK A DISK AS PREPARED FOR REMOVAL MegaCli -pdprprmv -physdrv[32:0] -a0 Here are some easy overview commands that I run when first looking at the storage on a system: MegaCli -AdpAllInfo -aAll |grep -A 8 "Device Present"; MegaCli -PDList -aALL |grep "Firmware...
2017 Jan 20
4
CentOS 7 and Areca ARC-1883I SAS controller: JBOD or not to JBOD?
On Fri, January 20, 2017 5:16 pm, Joseph L. Casale wrote: >> This is why before configuring and installing everything you may want to >> attach drives one at a time, and upon boot take a note which physical >> drive number the controller has for that drive, and definitely label it >> so >> y9ou will know which drive to pull when drive failure is reported. > >