2015 Sep 14
2
stale/dead ups logic
...tale/dead.
in Server A situation, I want to assume UPSA is "alive/no need
shutdown" when it is stale, but I want to assume UPSB is "dead/need
shutdown" when it is stale. to accomplish that, maybe uspmon can have
a flag to indicate that:
MONITOR ftups at localhost 1 monmaster passmaster master alive
MONITOR ftups at 10.1.1.1 1 monslave nutslave slave dead
maybe there are other situations that people want to declare "stale"
ups as "dead/need shutdown"..
Regards,
tbskyd
2015 Sep 11
3
"upsmon -c fsd" cause system shutdown
hi:
my testing server has two power supply and attach to two ups. one
of the ups is connect to the server with usb.
my upsmon.conf like below:
# for two ups
MONITOR ftups at localhost 1 monmaster nutmaster master
MONITOR ftups at 10.1.1.2 1 monslave nutslave slave
MINSUPPLIES 1
# for early shutdown
NOTIFYFLAG ONBATT EXEC+WALL+SYSLOG
NOTIFYFLAG ONLINE EXEC+WALL+SYSLOG
NOTIFYCMD