Displaying 10 results from an estimated 10 matches for "owch".
Did you mean:
ouch
2007 Apr 06
0
Background Processing Chapter in upcoming book
Hi BackgrounDRber''s,
I''m helping Obie Fernandez write a chapter on Background Processing in
his upcoming Pro Rails book, and wanted to see if I could run it past
the group. Any input is appreciated.
See attached (word doc, owch)!
p.s. thanks Ezra skaar, and File.read(CONTRIBUTORS).collect
Cheers,
--
Charles Brian Quinn
self-promotion: www.seebq.com
highgroove studios: www.highgroove.com
slingshot hosting: www.slingshothosting.com
main: 678.389.9462 fax: 678.826.0969
Ruby on Rails Bootcamp at the Big Nerd Ranch
Intens...
2007 Apr 08
0
Re: Nut-upsdev Digest, Vol 22, Issue 5
...---------------------
Message: 1
Date: Sat, 7 Apr 2007 15:20:16 -0400 (EDT)
From: "Oliver Wilcock"
Subject: Re: [Nut-upsdev] questions re. patching bcmxcp.c and choosing
variable names
To: nut-upsdev@lists.alioth.debian.org
Message-ID: <63999.74.112.254.142.1175973616.squirrel@shonsu.owch.ca>
Content-Type: text/plain;charset=iso-8859-1
Note quite the same as load.off. I think load.off is intended to turn off
the load permanently. load.n.cycle sounds more appropriate.
> Hi Oliver!
>
>> I've patched bcmxcp.c such that it can power cycle the outlet load
>> s...
2004 Feb 29
5
mbuf vulnerability
In
http://docs.freebsd.org/cgi/mid.cgi?200402260743.IAA18903
it seems RELENG_4 is vulnerable. Is there any work around to a system that
has to have ports open ?
Version: 1 2/18/2004@03:47:29 GMT
>Initial report
>
<<https://ialert.idefense.com/KODetails.jhtml?irId=207650>https://ialert.idefense.com/KODetails.jhtml?irId=207650;
>ID#207650:
>FreeBSD Memory Buffer
2008 Nov 25
0
RE: Xen GPL PV and undesirable requirement for APIC (irq >15)
...e with the non-APIC HAL, but I don''t see any
performance or CPU issues with the APIC MP HAL.
-Nick
-----Original Message-----
From: Venefax <venefax@gmail.com>
To: ''James Harper'' <james.harper@bendigoit.com.au>, ''Oliver Wilcock''
<oliver@owch.ca>, xen-users@lists.xensource.com
Subject: RE: [Xen-users] Xen GPL PV and undesirable requirement for APIC
(irq >15)
Date: Tue, 25 Nov 2008 10:03:48 -0500
I concur on seeing the issue. I changed the HAL to Standard PC (Non-apic)
and the Xennet driver strangely got an IP address from the DH...
2007 Apr 06
3
questions re. patching bcmxcp.c and choosing variable names
I've patched bcmxcp.c such that it can power cycle the outlet load
segments independently on a Powerware PW5125 UPS. I presume that it will
work for any XCP protocol UPS with 2 load segments.
Should these instant commands be called
outlet.1.shutdown.return
outlet.2.shutdown.return
?
Where do the descriptions displayed by upscmd -l come from? Presently it
shows
outlet.1.shutdown.return -
2004 Apr 07
6
dreaded Caller*ID failed checksum
Caller*ID used to work as some point, but I can't seem to get it going
these days. The card is a x101p. I've tried going up and down the
rxgain scale. Can the txgain effect it at all? When I plug in a phone
into the line with a splitter it can decode caller id with no problems.
Reading through the mailing list archives hasn't given me any
move clues. Any ideas?
2009 Aug 26
26
Xen and I/O Intensive Loads
Hi, folks,
I''m attempting to run an e-mail server on Xen. The e-mail system is Novell GroupWise, and it serves about 250 users. The disk volume for the e-mail is on my SAN, and I''ve attached the FC LUN to my Xen host, then used the "phy:/dev..." method to forward the disk through to the domU. I''m running into an issue with high I/O wait on the box (~250%)
2008 Dec 04
0
Are simultaneous VNC viewer connections to a single DomU possible?
I''ve found that if a vncviewer is already connected to a DomU (ie
vncveiwer dom0server:5901) then another connection attempt hangs (it seems
to go into a queue).
Is it possible to change this behaviour in any of the following ways?
- simultaneous connections mean that users fight over mouse and keyboard
- the new connection breaks the old
- the length of the connection is limited
Are
2009 Jan 06
0
RE: GPLPV drivers problem, switching HALs
> Date: Tue, 6 Jan 2009 13:58:55 +1100
> From: "James Harper" <james.harper@bendigoit.com.au>
> Subject: RE: [Xen-users] GPLPV drivers problem
> To: "Nick Couchman" <Nick.Couchman@seakr.com>, "Venefax"
> <venefax@gmail.com>, <xen-users@lists.xensource.com>,
> <lfernandes@lojav.pt>
> Message-ID:
2007 Jul 09
1
bcmxcp - patch for power cycling individual outlets/load segments
Also works if you want to shutdown one segment/outlet early in the power
failure. It should stay off until utility power returns and then apply
the configured delay - although I haven't tested this aspect.
-------------- next part --------------
An embedded and charset-unspecified text was scrubbed...
Name: bcmxcp.c.diff
Url: