2017 Oct 31
2
Email Alerts for Multiple UPSs with upssched
Ah! So I can detect the source UPS in the upssched.conf and pass it as a distinct event to the shell script. That sounds like an excellent approach. Thanks! GMH From: O'Shaughnessy, Mike [mailto:Mike.OShaughnessy at gd-ms.com] Sent: Tuesday, October 31, 2017 12:46 PM To: Garrett Michael Hayes <Garrett at VerbalImaging.com>; nut-upsuser at lists.alioth.debian.org Subject: RE: Email Alerts for Multiple UPSs with upssched I'm running a single "nut-server" that monitors seven ups units. In...
2017 Oct 31
0
Email Alerts for Multiple UPSs with upssched
...user at lists.alioth.debian.org Subject: RE: Email Alerts for Multiple UPSs with upssched Ah! So I can detect the source UPS in the upssched.conf and pass it as a distinct event to the shell script. That sounds like an excellent approach. Thanks! GMH From: O'Shaughnessy, Mike [mailto:Mike.OShaughnessy at gd-ms.com] Sent: Tuesday, October 31, 2017 12:46 PM To: Garrett Michael Hayes <Garrett at VerbalImaging.com<mailto:Garrett at VerbalImaging.com>>; nut-upsuser at lists.alioth.debian.org<mailto:nut-upsuser at lists.alioth.debian.org> Subject: RE: Email Alerts for Multiple UPSs w...
2017 Oct 31
4
Email Alerts for Multiple UPSs with upssched
Greetings Gentlebeings, I have started deploying a number of NUT instances on Raspberry Pi machines (Raspbian Jessie) across my network. The purpose of these "nutcases" as we refer to them is to monitor the status of the UPSs supporting our network switching infrastructure and notify us of power and battery events via email. No shutdown or other actions are required. Everything is
2007 May 03
4
Finding instrumented code
Hi all, So I just took Sun''s dtrace class this week and one thing that piqued my interest was the instrumenting of a process''s instructions and how to find the original instructions. (I''m looking around at resources for learning SPARC assembly to help me when using mdb for analysis, though I vaguely remember pieces from a grad school compiler theory class about 10 years
2017 Oct 31
0
Email Alerts for Multiple UPSs with upssched
...UPS-N' do this: * Foreach linux box on the ups, log in and issue "shutdown -h now" * Foreach VMWare server on the ups, log in and issue "/sbin/shutdown.sh && /sbin/poweroff" Hope that helps! Mike From: Nut-upsuser [mailto:nut-upsuser-bounces+mike.oshaughnessy=gd-ms.com at lists.alioth.debian.org] On Behalf Of Garrett Michael Hayes Sent: Tuesday, October 31, 2017 11:10 AM To: nut-upsuser at lists.alioth.debian.org Subject: [Nut-upsuser] Email Alerts for Multiple UPSs with upssched Greetings Gentlebeings, I have started deploying a number of NUT instanc...