2012 Jan 12
1
Debian Squeeze / Powerware 9135 450KVA UPS
Hi All,
I'm a system administrator of a large data center, and I've recently
replaced the machine that acted as the nut master for our
cluster/cloud. The machine that was interfacing with our Powerware
9135 450KVA 3 phase UPS, not to confused with Eaton's Powerware 9135,
and was a Fedora Core 4 box running nut version 2.0.3-4 connected by a
serial cable.
We are using these versions
2010 Jun 22
1
Powerware 9120 / bcmxcp losing communication
...AUTO_ON_COMMAND_EXECUTED No
11.986338 0019 BATTERY_TEST_FAILED Yes
11.986341 -001 FUSE_FAIL No
11.986344 -001 FAN_FAIL No
11.986347 0020 SITE_WIRING_FAULT Yes
11.986351 -001 BACKFEED_CONTACTOR_FAIL No
11.986354 -001 ON_BUCK No
11.986357 -001 ON_BOOST No
11.986360 -001 ON_DOUBLE_BOOST No
11.986363 0021 BATTERIES_DISCONNECTED Yes
11.986366 -001 UPS_CABINET_OVER_TEMP No
11.986370 -001 TRANSFORMER_OVER_TEMP No
11.986373 -001 AMBIENT_UNDER_TEMP No
11....
2010 Mar 05
5
Getting 'Data stale' error with bcmxcp_usb for a PowerWare 5115 on OSX
...D_EXECUTED No
1.107253 -001 AUTO_ON_COMMAND_EXECUTED No
1.107266 0013 BATTERY_TEST_FAILED Yes
1.107281 -001 FUSE_FAIL No
1.107295 0014 FAN_FAIL Yes
1.107309 0015 SITE_WIRING_FAULT Yes
1.107323 -001 BACKFEED_CONTACTOR_FAIL No
1.107337 -001 ON_BUCK No
1.107351 -001 ON_BOOST No
1.107365 -001 ON_DOUBLE_BOOST No
1.107379 -001 BATTERIES_DISCONNECTED No
1.107393 -001 UPS_CABINET_OVER_TEMP No
1.107407 -001 TRANSFORMER_OVER_TEMP No
1.107421 -001 AMBIENT_UNDER_TEMP No
1.107435 0016 AMBIENT_OVE...
2010 Mar 05
5
Getting 'Data stale' error with bcmxcp_usb for a PowerWare 5115 on OSX
...D_EXECUTED No
1.107253 -001 AUTO_ON_COMMAND_EXECUTED No
1.107266 0013 BATTERY_TEST_FAILED Yes
1.107281 -001 FUSE_FAIL No
1.107295 0014 FAN_FAIL Yes
1.107309 0015 SITE_WIRING_FAULT Yes
1.107323 -001 BACKFEED_CONTACTOR_FAIL No
1.107337 -001 ON_BUCK No
1.107351 -001 ON_BOOST No
1.107365 -001 ON_DOUBLE_BOOST No
1.107379 -001 BATTERIES_DISCONNECTED No
1.107393 -001 UPS_CABINET_OVER_TEMP No
1.107407 -001 TRANSFORMER_OVER_TEMP No
1.107421 -001 AMBIENT_UNDER_TEMP No
1.107435 0016 AMBIENT_OVE...
2011 Aug 29
0
BCMXCP UPS driver 0.24 (2.6.1) Hangs
...AUTO_ON_COMMAND_EXECUTED No
7.284921 0013 BATTERY_TEST_FAILED Yes
7.284941 -001 FUSE_FAIL No
7.284959 0014 FAN_FAIL Yes
7.284978 -001 SITE_WIRING_FAULT No
7.284997 -001 BACKFEED_CONTACTOR_FAIL No
7.285016 -001 ON_BUCK No
7.285035 -001 ON_BOOST No
7.285054 -001 ON_DOUBLE_BOOST No
7.350243 -001 BATTERIES_DISCONNECTED No
7.350282 -001 UPS_CABINET_OVER_TEMP No
7.350329 -001 TRANSFORMER_OVER_TEMP No
7.350372 -001 AMBIENT_UNDER_TEMP No
7.3...