Displaying 20 results from an estimated 110 matches for "ohms".
Did you mean:
oems
2010 Oct 23
2
B410P - BRI NT 100 Ohm terminator
Hi,
My set up is :
Asterisk with B410P in NT mode <-------------cat5 straight cable
----------------> Another PBX in TE mode
Is the 100 Ohm terminator you can find on B410P boards, necessary when
connecting in NT mode to another PBX (set in TE mode) ?
Cheers
-------------- next part --------------
An HTML attachment was scrubbed...
URL:
2006 Jan 14
4
tuning an x100p in Australia for echocancellation
...eg, 600 ohm
> impedence)?
This is a question I've been trying to answer too. I had a look at the
standard phone that Telstra would provide to customers about 5 years
ago, and it has an impedence switch on the bottom to toggle between
'NORM' and '600', which suggests that 600 ohms isn't the normal
impedence.
On an au configuration example for the pap2 I have seen on the web, the
impedence is set to '220+820||120nF', which suggests that our standard
here isn't 600.
> > Does anyone know of an addon device which
> > can do impedence matching on th...
2015 May 20
4
Help With Physical Layer
...t
is also well configured because when I interchange the cables (with the
exiting cable from the other telco), the alarm clears emmediately for the
1st telco and becomes RED for the 2nd telco. A loop also clears the alarm
on both ports.
The telco has told me to make sure that Line Impedance is 120 ohms but
There's no where to set that and when I was reading, I was told that E1 is
already 120 ohms so no need to change anything.
Has anyone here experienced this? What other things can I try?
Thank you!
Regards,
Tim
-------------- next part --------------
An HTML attachment was scrubbed...
UR...
2008 Apr 12
2
X100M never goes on-hook state
...Digium card (TDM2400), it works ok. The
same with my Brazilian DigiVoice FXO card.
Ok, you all might say: your card is damaged, throw it away. Ok, I could
do it, but now comes the funny part:
If I put an DSL filter in series with the line and the card, IT WORKS
PERFECTLY!!! The filter imposes 25 ohms over the circuit. Maybe that's
causing the card to work. When I put the filter and the ammeter in
series, I get zero amper when on-hook and 26 mA when off-hook, that's
the expected behaviour.
I'm not an expert in electricity, so I really don't know why the card is
behaving that way...
2005 Jan 09
1
passing opermode to the wcfxs module
...? how would i
pass the opermode=AUSTRALIA parameter to the wcfxs.ko module as kldload
doesnt let you pass parameters to the module like modprobe in Linux.
I tried to get the sysctl variable using sysctl -a it might use but
nothing applicable was visible....
i need to set the impedences to 600 ohms, can someone please advice me
on how to pass the parameters to the module?
regards
Kavit
2009 Jul 15
3
Axes origins and labeling
...have the 3rd and 4th axes in
there as well, all meeting in their respective corners.
par(mfrow=c(1,2))
gut<-c("Full", "Empty", "Full", "Empty")
par(family="serif", cex=1.2, lab=c(length(gut),4,4))
boxplot(Xc~Trt,data=error,ylab="Reactance (Ohms)",xlab="Stomach Fullness",
ylab="Reactance (Ohms)", axes=FALSE,ylim=c(50,200))
axis(side=1, at=c(1,2,3,4), labels=gut)
axis(side=2)
text(1.5,115, "Mid BIA")
text(3.5,160, "Whole BIA")
points(1,135, pch=2)
points(2,135, pch=2)
points(3,135, pch=17)
points...
2015 Jun 30
2
Help With Physical Layer
...terchange the cables
>>(with the exiting cable from the other telco), the alarm clears
>>emmediately for the 1st telco and becomes RED for the 2nd telco. A
>>loop also clears the alarm on both ports.
>>
>>The telco has told me to make sure that Line Impedance is 120 ohms but
>>There's no where to set that and when I was reading, I was told that
>>E1 is already 120 ohms so no need to change anything.
>>
>>Has anyone here experienced this? What other things can I try?
>>
>>Thank you!
>>
>>Regards,
>>Tim
>...
2006 Jan 13
1
tuning an x100p in Australia for echo cancellation
I have an x100p which suffers from echo (no surprise there apparantly
:), and a few of the things I've read about tuning out echo say the
first thing to get right is the tx and rx gain, and for that you need a
few different types of test lines from the telco (Telstra, Optus,
whatever). Does anyone have any numbers in Australia for such lines? I
think they just need to send out a tone of a
2004 Nov 19
2
E100 or TE410 card an PRA line
We are located in Belgium and just ordered a PRA line, the telco asked the following questions :
- 120 or 75 ohm ?
- Support for CRC4 yes/no ?
- B channels in 2 way ?
We will buy a digium card but which one should we buy ?
could anybody help me with this ?
Thank you
Michael
Sorry for the previous html mail
DISCLAIMER: The content of this e-mail message does not constitute a commitment
2007 Dec 28
1
unit attribute to list elements
Hi,
I've started my own (first) package, part of which consists in
listing common physical constants (Planck's constant, the speed of
light in vacuum, etc). I'm wondering what would be a good way of
dealing with pairs of value/unit.
> constants <- list( cel = 2.99792458e8 , #m/s
> Z0 = 376.730313461, #ohm
> eps0 = 8.854187817e-12,#F/m
> mu0 = 4*pi*1e-7,#N/A^2
2004 Aug 29
2
Still unacceptable echo on X101P
I am still having unacceptable echo on my X101P and twidling with the
rx/tx gain levels and echo settings appears to have no discernable
effect.
Some questions for those who may have more significant electrical
engineering background than I.
1. This impedance match thing ... will it affect this solution having
other phones in parallel with the X101P? This is done so that I can
test while not
2015 Jun 30
1
Help With Physical Layer
...erchange the cables (with the
>> exiting cable from the other telco), the alarm clears emmediately for the
>> 1st telco and becomes RED for the 2nd telco. A loop also clears the alarm
>> on both ports.
>>
>> The telco has told me to make sure that Line Impedance is 120 ohms but
>> There's no where to set that and when I was reading, I was told that E1 is
>> already 120 ohms so no need to change anything.
>>
>> Has anyone here experienced this? What other things can I try?
>>
>> Thank you!
>>
>> Regards,
>> Tim...
2005 Jul 16
3
Multiple ISDN BRI Units with Asterisk usingBristuff zaphfc in NT mode?
-----Original Message-----
From: asterisk-users-bounces@lists.digium.com
[mailto:asterisk-users-bounces@lists.digium.com] On Behalf Of Zoltan Szecsei
Sent: zaterdag 16 juli 2005 12:54
To: Asterisk Users Mailing List - Non-Commercial Discussion
Subject: Re: [Asterisk-Users] Multiple ISDN BRI Units with Asterisk
usingBristuff zaphfc in NT mode?
>> Maybe this is rather a hardware question,
2004 May 31
2
Crc4 issues
Hi All,
This is our 2nd E1 client that we try to use crc4 either with the e100p
or with the e405p without luck.
After some trials, we ask the telco to switch off crc4 on their side and
everything works flawlessly.
Is there anything in the crc4 calculation that may be broken? We took a
look at wct1xxx.c and wct4xx.c but there doesn't seem to be much there
to be fixed (apparently the crc4
2015 Jun 30
1
Help With Physical Layer
...erchange the cables (with the
>> exiting cable from the other telco), the alarm clears emmediately for the
>> 1st telco and becomes RED for the 2nd telco. A loop also clears the alarm
>> on both ports.
>>
>> The telco has told me to make sure that Line Impedance is 120 ohms but
>> There's no where to set that and when I was reading, I was told that E1 is
>> already 120 ohms so no need to change anything.
>>
>> Has anyone here experienced this? What other things can I try?
>>
>> Thank you!
>>
>> Regards,
>> Tim...
2002 Apr 16
6
Classification Analysis
Hi everyone,
Could somebody explain to me what is the package/function for
classification analysis. I am performing analysis of music files in the form
of MIDI files. I end up with about 750 dependent variables from the
analysis, I also have a number of independent/grouping variables that I set
manually. What I would like is to be able to predict which group a
particular MIDI files belongs to
2008 Nov 26
7
Dahdi, b410p and looping from 1 port to another
Hello,
Is it possible, for testing, to connect an cat5 straight patch cord between
2 ports of a Digium B410P card and use these 2 ports as a normal dahdi trunk
?
I've tried this:
One port is set as NT, the other as TE.
I would expect timing to come for system hardware so I choose in
/etc/dahdi/system.conf :
span=1,0,0,ccs,ami
span=2,0,0,ccs,ami
Results:
- both ports lights are green
-
2014 Jun 10
2
Overload Point for OPUS
Hello,
Can you please tell me what the overload point is for OPUS in dBm0 or dBV?
As an example, the G.711 A law codec has an overload point of +3.14 dBm0
across a 600 ohm circuit.
In ITU-T G.100.1 section 5.8 you can read more about the relationship
between dBm0 and dBov. In that same section you can see that the G.711 A
law, u law, and G.722 codec overload points are also defined.
2004 Jun 24
7
X101P on a UK BT line ---- txgain issue
I am finding that I have to increase the txgain in zapata.conf to 8 when my
X101P is connected to my BT phone line, otherwise people can hardly hear me.
This then gives echo issues.
Do other people have the same problem on BT lines. I was wondering if I
should give BT a call and get them to increase the gain on the line. Strange
though as the rxgain is OK and I don't have this problem with
2005 Aug 09
0
How to lower float charge voltage of an APC Smart UPS unit
You can lower the float charge voltage that APC Smart UPS units such as
SU1000NET or SU700NET supply to the battery. This is important when
substituting Lead Acid Deep Cycle batteries for the usual sealed maintenance
free batteries provided. Here are the instructions:
1) Only do this if you are fully trained and qualified to work on Lead Acid
powered UPS. These units contain lethal voltages