Displaying 2 results from an estimated 2 matches for "nouveau_therm_thrs_fanboost".
2013 Feb 03
1
[PATCH 1/3] drm/nouveau/therm: turn on a fan only when crossing threshold in positive direction
...; threshold\n",
temperature, thresolds[thrs]);
else
nv_info(therm, "temperature (%u C) hit the '%s' threshold\n",
@@ -114,8 +114,10 @@ void nouveau_therm_sensor_event(struct nouveau_therm *therm,
active = (dir == NOUVEAU_THERM_THRS_RISING);
switch (thrs) {
case NOUVEAU_THERM_THRS_FANBOOST:
- nouveau_therm_fan_set(therm, true, 100);
- nouveau_therm_mode(therm, NOUVEAU_THERM_CTRL_AUTO);
+ if (active) {
+ nouveau_therm_fan_set(therm, true, 100);
+ nouveau_therm_mode(therm, NOUVEAU_THERM_CTRL_AUTO);
+ }
break;
case NOUVEAU_THERM_THRS_DOWNCLOCK:
if (priv->emergency.dow...
2013 Aug 12
5
[PATCH 0/5] Thermal management fixes
From: Martin Peres <martin.peres at labri.fr>
This patchset is mostly about fixing fdo bug #66177, reported by Dash Four.
This bug is about fan/temp management not working after a suspend/resume cycle.
Fan/therm management relies on ptimer's alarm feature to call periodically
multiple callbacks that poll the temperature and update the fan speed if needed.
The problem is that there is