Displaying 16 results from an estimated 16 matches for "meinbergglobal".
2020 Nov 18
6
Time sync not working with Windows 10
...ths users started noticing up to
+/-6 minutes difference between their computers and the *real* time.
Going to 'Date & Time settings > Sync Now' always gives "Time synchronization failed".
For Windows 7 workstations, several years ago, I followed the advice in
https://www.meinbergglobal.com/english/info/ntp-w32time.htm which was to do the following on
the Windows 7 workstations:
w32tm /config /manualpeerlist:mail,0x8 /syncfromflags:MANUAL
w32tm /config /update
Check the configuration:
w32tm /query /source
This worked and time was in-sync on the WIN7 computers for many years....
2017 Jan 31
0
Samba-4.3 AD-DC Win7pro clients not time syncing
...nt by w32time. w32time sends namely symmetric active instead of client mode packets
to a NTP server. ... The flag "0x8" forces w32time not to send "symmetric active" packets but
normal "client" requests which the NTP server replies to as usual."
ref. https://www.meinbergglobal.com/english/info/ntp-w32time.htm
--Mark
2017 Jun 30
2
Problems with time synchronism on Samba 4 DC
Hi,
The Windows and Linux workstations are not synchronizing the time with the
Samba 4 DC. I have verified that the problem is permission.
I'm using Samba 4.6.3 on Debian 8.
In this way the stations are with different schedules from the DC.
Do I need to configure any GPOs?
What is the maximum time the computer clock can differ from DC ?
Regards,
Márcio
2020 Nov 18
0
Time sync not working with Windows 10
...p to
> +/-6 minutes difference between their computers and the *real* time.
>
> Going to 'Date & Time settings > Sync Now' always gives "Time synchronization failed".
>
> For Windows 7 workstations, several years ago, I followed the advice in
> https://www.meinbergglobal.com/english/info/ntp-w32time.htm which was to do the following on
> the Windows 7 workstations:
>
>
> w32tm /config /manualpeerlist:mail,0x8 /syncfromflags:MANUAL
> w32tm /config /update
>
> Check the configuration:
>
> w32tm /query /source
>
> This worked and time...
2015 Aug 26
8
sernet documentation
...ssage, but I had to do the following on each Windows
workstation (command line) to get time to synchronize with ntpd where "mail" is
the hostname of my AD/DC and domain time server:
w32tm /config /manualpeerlist:mail,0x8 /syncfromflags:MANUAL
w32tm /config /update
reference: https://www.meinbergglobal.com/english/info/ntp-w32time.htm
Hope this helps
--Mark
-----Original Message-----
> Date: Wed, 26 Aug 2015 21:28:55 +0100
> From: Rowland Penny <rowlandpenny241155 at gmail.com>
> To: Robert Moskowitz <rgm at htt-consult.com>, samba at lists.samba.org
> Subject: Re: [Sam...
2020 Nov 22
0
Time sync not working with Windows 10
...mputers and the *real* time.
> > >
> > > Going to 'Date & Time settings > Sync Now' always gives "Time synchronization failed".
> > >
> > > For Windows 7 workstations, several years ago, I followed the advice in
> > > https://www.meinbergglobal.com/english/info/ntp-w32time.htm which was to do the following on
> > > the Windows 7 workstations:
> > >
> > >
> > > w32tm /config /manualpeerlist:mail,0x8 /syncfromflags:MANUAL
> > > w32tm /config /update
> > >
> > > Check the configu...
2017 Jan 30
3
Samba-4.3 AD-DC Win7pro clients not time syncing
We have a Samba-4.3 AD-DC hosted on a FreeBSD-10.3 system. We have
just discovered that for some reason our domain workstations are not
synchronising their time with the AD-DC. We have not altered the
default GPO nor have we created a special GPO to handle time services.
I have been working on several of the domain clients and I cannot seem
to get them to source from the Samba server. I have
2015 Aug 26
0
sernet documentation
...ing on each Windows
> workstation (command line) to get time to synchronize with ntpd where "mail" is
> the hostname of my AD/DC and domain time server:
>
> w32tm /config /manualpeerlist:mail,0x8 /syncfromflags:MANUAL
> w32tm /config /update
>
> reference: https://www.meinbergglobal.com/english/info/ntp-w32time.htm
>
> Hope this helps
>
> --Mark
>
> -----Original Message-----
>> Date: Wed, 26 Aug 2015 21:28:55 +0100
>> From: Rowland Penny <rowlandpenny241155 at gmail.com>
>> To: Robert Moskowitz <rgm at htt-consult.com>, samba at...
2015 Aug 27
4
sernet documentation
...tation (command line) to get time to synchronize with ntpd where "mail" is
> > the hostname of my AD/DC and domain time server:
> >
> > w32tm /config /manualpeerlist:mail,0x8 /syncfromflags:MANUAL
> > w32tm /config /update
> >
> > reference: https://www.meinbergglobal.com/english/info/ntp-w32time.htm
> >
> > Hope this helps
> >
> > --Mark
> >
> > -----Original Message-----
> >> Date: Wed, 26 Aug 2015 21:28:55 +0100
> >> From: Rowland Penny <rowlandpenny241155 at gmail.com>
> >> To: Robert Mosko...
2020 Nov 23
0
Time sync not working with Windows 10
...gt;>>>
> >>>> Going to 'Date & Time settings > Sync Now' always gives "Time synchronization failed".
> >>>>
> >>>> For Windows 7 workstations, several years ago, I followed the advice in
> >>>> https://www.meinbergglobal.com/english/info/ntp-w32time.htm which was to do the following on
> >>>> the Windows 7 workstations:
> >>>>
> >>>>
> >>>> w32tm /config /manualpeerlist:mail,0x8 /syncfromflags:MANUAL
> >>>> w32tm /config /update
> >>...
2015 Aug 27
1
sernet documentation
...nize with
> >ntpd where "mail" is
> >> the hostname of my AD/DC and domain time server:
> >>
> >> w32tm /config /manualpeerlist:mail,0x8 /syncfromflags:MANUAL
> >> w32tm /config /update
> >>
> >> reference:
> >https://www.meinbergglobal.com/english/info/ntp-w32time.htm
> >>
> >> Hope this helps
> >>
> >> --Mark
> >>
> >> -----Original Message-----
> >>> Date: Wed, 26 Aug 2015 21:28:55 +0100
> >>> From: Rowland Penny <rowlandpenny241155 at gmail.com>...
2015 Aug 27
0
sernet documentation
...on (command line) to get time to synchronize with
>ntpd where "mail" is
>> the hostname of my AD/DC and domain time server:
>>
>> w32tm /config /manualpeerlist:mail,0x8 /syncfromflags:MANUAL
>> w32tm /config /update
>>
>> reference:
>https://www.meinbergglobal.com/english/info/ntp-w32time.htm
>>
>> Hope this helps
>>
>> --Mark
>>
>> -----Original Message-----
>>> Date: Wed, 26 Aug 2015 21:28:55 +0100
>>> From: Rowland Penny <rowlandpenny241155 at gmail.com>
>>> To: Robert Moskowitz <...
2016 Jul 29
2
Replace SBS2003 with Samba4
Hello all,
I'm currently investigating the option to completely replace a SBS2003 DC
with a Samba4 DC. My research (mostly on samba.org guides) shows that it is
feasible, however I'd like to get feedback from the community on my goals.
Current status:
A Windows SBS 2003 is the PDC and a W2008 R2 server is acting as secondary
DC. Domain operational level is 2003.
There are ~40-50
2016 Aug 11
0
Replace SBS2003 with Samba4
...ba4 AD/DC to the real office LAN and boot. One by one, join each
workstation to the domain.
IMPORTANT! time synchronization needs to be maintained between the AD/DC and worksations. Of
course, make sure ntpd is running on the AD/DC. However, Windows does not play nicely with ntpd,
see: https://www.meinbergglobal.com/english/info/ntp-w32time.htm
To fix this, log into the workstation as the domain administrator, get to a command prompt, and
enter the following commands:
> w32tm /config /manualpeerlist:mail,0x8 /syncfromflags:MANUAL
> w32tm /config /update
Add Domain Users
In RSAT, Active Directory...
2017 May 24
11
System Time Source
One of our STEM interns recently observed that there are
inexpensive clocks that sync via radio to standard time
services.? This begged a question about why every computer
would not have a radio module to receive time.? Our senior
staff did not have a good answer or if time from such a
radio module would be supported by the operating system.
When I was a student, such questions would have earned
2015 Aug 26
4
sernet documentation
On 08/26/2015 03:50 PM, Rowland Penny wrote:
> On 26/08/15 20:39, Robert Moskowitz wrote:
>>
>>
>> On 08/26/2015 03:26 PM, Rowland Penny wrote:
>>> On 26/08/15 20:14, Robert Moskowitz wrote:
>>>> One of the Centos 7 arm developers built the sernet 4.2 for me to
>>>> start testing.
>>>>
>>>>