search for: mbaehr

Displaying 6 results from an estimated 6 matches for "mbaehr".

Did you mean: baehr
2023 Mar 23
1
hardware issues and new server advice
Hi, Am Di., 21. M?rz 2023 um 23:36 Uhr schrieb Martin B?hr <mbaehr+gluster at realss.com>: > the primary data is photos. we get an average of 50000 new files per > day, with a peak if 7 to 8 times as much during christmas. > > gluster has always been able to keep up with that, only when raid resync > or checks happen the server load sometimes inc...
2023 Mar 21
1
hardware issues and new server advice
Excerpts from Strahil Nikolov's message of 2023-03-21 00:27:58 +0000: > Generally,the recommended approach is to have? 4TB disks and no more > than 10-12 per HW RAID. what kind of raid configuration and brick size do you recommend here? > Of course , it's not always possible but a > resync of a failed 14 TB drive will take eons. right, that is my concern too. but with raid
2023 Mar 25
1
hardware issues and new server advice
...u have a caching layer, then LVM cache is an overkill. Why don't you mount the old system's volume on one of the new gluster servers and 'cp' from the first FUSE mount point to the new FUSE mount point ? Best Regards,Strahil Nikolov? On Sat, Mar 25, 2023 at 3:31, Martin B?hr<mbaehr+gluster at realss.com> wrote: Excerpts from Strahil Nikolov's message of 2023-03-24 21:11:28 +0000: > Gluster excells when you have more servers and clients to consume that data. you mean multiple smaller servers are better than one large server? > LVM cache (NVMEs) we only have a...
2023 Mar 25
1
hardware issues and new server advice
Excerpts from Strahil Nikolov's message of 2023-03-24 21:11:28 +0000: > Gluster excells when you have more servers and clients to consume that data. you mean multiple smaller servers are better than one large server? > LVM cache (NVMEs) we only have a few clients. gluster is for us effectively only a scalable large file storage for one application. new files are written once and then
2023 Mar 18
1
hardware issues and new server advice
hi, our current servers are suffering from a weird hardware issue that forces us to start over. in short we have two servers with 15 disks at 6TB each, divided into three raid5 arrays for three bricks per server at 22TB per brick. each brick on one server is replicated to a brick on the second server. the hardware issue is that somewhere in the backplane random I/O errors happen when the system
2023 Mar 24
2
hardware issues and new server advice
...tting server hardware.Dispersed volumes require a lot of CPU computations and the Ryzens won't cope with the load. Best Regards,Strahil Nikolov? On Thu, Mar 23, 2023 at 12:16, Hu Bert<revirii at googlemail.com> wrote: Hi, Am Di., 21. M?rz 2023 um 23:36 Uhr schrieb Martin B?hr <mbaehr+gluster at realss.com>: > the primary data is photos. we get an average of 50000 new files per > day, with a peak if 7 to 8 times as much during christmas. > > gluster has always been able to keep up with that, only when raid resync > or checks happen the server load sometimes inc...