Displaying 7 results from an estimated 7 matches for "matthew4196".
2014 Aug 08
2
Cyberpower Value1200E might not need 0.667 battery scaling
On Aug 7, 2014, at 10:52 PM, Charles Lepple <clepple at gmail.com> wrote:
> On Aug 7, 2014, at 10:18 PM, Matthew Stapleton <matthew4196 at gmail.com> wrote:
>
>> I just got a Cyberpower SOHO Value 1200 ELCD UPS and even with nut 2.7.2, it appears to report battery voltage too low due to the battery scaling function (In drivers/cps-hid.c). Even though the ups has usb id: 0764:0501, UPS.PowerSummary.Voltage reports 26.6...
2014 Aug 08
2
Cyberpower Value1200E might not need 0.667 battery scaling
...tes 3
Transfer Type Interrupt
Synch Type None
Usage Type Data
wMaxPacketSize 0x0008 1x 8 bytes
bInterval 10
Device Status: 0x0000
(Bus Powered)
--
Matthew Stapleton
Email: matthew4196 at gmail.com
2014 Aug 11
1
Cyberpower Value1200E might not need 0.667 battery scaling
Attached is the first 32 seconds of the driver output after applying the
patch which fixes the battery scaling problem for this UPS.
Matthew Stapleton
Email: matthew4196 at gmail.com
On 10/08/14 01:27, Charles Lepple wrote:
> On Aug 8, 2014, at 9:15 AM, Charles Lepple <clepple at gmail.com> wrote:
>
>> On Aug 7, 2014, at 10:52 PM, Charles Lepple <clepple at gmail.com> wrote:
>>
>>> On Aug 7, 2014, at 10:18 PM, Matthew Staplet...
2014 Aug 09
0
Cyberpower Value1200E might not need 0.667 battery scaling
On Aug 8, 2014, at 9:15 AM, Charles Lepple <clepple at gmail.com> wrote:
> On Aug 7, 2014, at 10:52 PM, Charles Lepple <clepple at gmail.com> wrote:
>
>> On Aug 7, 2014, at 10:18 PM, Matthew Stapleton <matthew4196 at gmail.com> wrote:
>>
>>> I just got a Cyberpower SOHO Value 1200 ELCD UPS and even with nut 2.7.2, it appears to report battery voltage too low due to the battery scaling function (In drivers/cps-hid.c). Even though the ups has usb id: 0764:0501, UPS.PowerSummary.Voltage repor...
2014 Aug 08
0
Cyberpower Value1200E might not need 0.667 battery scaling
On Aug 7, 2014, at 10:18 PM, Matthew Stapleton <matthew4196 at gmail.com> wrote:
> I just got a Cyberpower SOHO Value 1200 ELCD UPS and even with nut 2.7.2, it appears to report battery voltage too low due to the battery scaling function (In drivers/cps-hid.c). Even though the ups has usb id: 0764:0501, UPS.PowerSummary.Voltage reports 26.6 for the...
2019 May 29
2
[Bug 13974] New: Old max block size isn't allowed in options
...ock size isn't allowed in options
Product: rsync
Version: 3.1.3
Hardware: All
OS: All
Status: NEW
Severity: normal
Priority: P5
Component: core
Assignee: wayne at opencoder.net
Reporter: matthew4196 at gmail.com
QA Contact: rsync-qa at samba.org
Created attachment 15199
--> https://bugzilla.samba.org/attachment.cgi?id=15199&action=edit
rsync_allow_old_max_block_size_in_options.patch
Old large block sizes with protocol < 30 aren't allowed due to a check in
options.c ad...
2014 Aug 10
1
USB device descriptor read error with Eaton 5E UPS
On 10 August 2014 09:05, Charles Lepple <clepple at gmail.com> wrote:
> On Aug 7, 2014, at 7:57 AM, Leith Bade <leith at leithalweapon.geek.nz> wrote:
>
> Error -32 is EPIPE, which means that the PC didn't see a reply from the device during the descriptor read. I don't know that we have ever successfully run one of these issues to ground.
>
Considering Eaton do