Displaying 20 results from an estimated 25 matches for "manufacturerdate".
2005 Aug 26
0
NUT patches
...Before fixing the HIDParser bug:
HIDDumpTree...
Path: UPS.PowerSummary.iSerialNumber
Path: UPS.PowerSummary.iDeviceChemistry
Path: UPS.PowerSummary.iOEMInformation
Path: UPS.PowerSummary.Rechargeable
Path: UPS.PowerSummary.APCStatusFlag
Path: UPS.PowerSummary.APCStatusFlag
Path: UPS.PowerSummary.ManufacturerDate
Path: UPS.PowerSummary.ConfigVoltage
Path: UPS.PowerSummary.Voltage
Path: UPS.PowerSummary.iManufacturer
Path: UPS.PowerSummary.CapacityMode
Path: UPS.PowerSummary.RemainingCapacity
Path: UPS.PowerSummary.RemainingCapacity
Path: UPS.PowerSummary.RunTimeToEmpty
Path: UPS.PowerSummary.RunTimeToEmpty...
2005 Jul 22
1
Another HID USB UPS
...an UPS: APC/Back-UPS ES 650 FW:818.w1.D USB FW:w1
Path: UPS.PowerSummary.iSerialNumber
Path: UPS.PowerSummary.iDeviceChemistry
Path: UPS.PowerSummary.iOEMInformation
Path: UPS.PowerSummary.Rechargeable
Path: UPS.PowerSummary.APCStatusFlag
Path: UPS.PowerSummary.APCStatusFlag
Path: UPS.PowerSummary.ManufacturerDate
Path: UPS.PowerSummary.ConfigVoltage
Path: UPS.PowerSummary.Voltage
Path: UPS.PowerSummary.iManufacturer
Path: UPS.PowerSummary.CapacityMode
Path: UPS.PowerSummary.RemainingCapacity
Path: UPS.PowerSummary.RemainingCapacity
Path: UPS.PowerSummary.RunTimeToEmpty
Path: UPS.PowerSummary.RunTimeToEmpty...
2005 Aug 02
0
newhidups for APC Back-UPS ES 650
...USB FW:w1
.............  output heavily reduced!
Path: UPS.PowerSummary.iSerialNumber
Path: UPS.PowerSummary.iDeviceChemistry
Path: UPS.PowerSummary.iOEMInformation
Path: UPS.PowerSummary.Rechargeable
Path: UPS.PowerSummary.APCStatusFlag
Path: UPS.PowerSummary.APCStatusFlag
Path: UPS.PowerSummary.ManufacturerDate
Path: UPS.PowerSummary.ConfigVoltage
Path: UPS.PowerSummary.Voltage
Path: UPS.PowerSummary.iManufacturer
Path: UPS.PowerSummary.CapacityMode
Path: UPS.PowerSummary.RemainingCapacity
Path: UPS.PowerSummary.RemainingCapacity
Path: UPS.PowerSummary.RunTimeToEmpty
Path: UPS.PowerSummary.RunTimeToEmpty...
2007 Jan 26
1
newhidups output for Geek Squad GS1285U
...e: 0.000000
Path: UPS.Output.Overload, Type: Feature, Value: 0.000000
Path: UPS.Output., Type: Feature
Path: UPS.Output.ConfigActivePower, Type: Feature, Value: 238.000000
Can't find object UPS.Battery.ConfigVoltage
Can't find object UPS.Battery.Temperature
Can't find object UPS.Battery.ManufacturerDate
Can't find object UPS.PowerSummary.APCBattReplaceDate
Can't find object UPS.Battery.APCBattReplaceDate
Can't find object UPS.PowerSummary.DelayBeforeShutdown
Can't find object UPS.APCGeneralCollection.APCDelayBeforeShutdown
Can't find object UPS.Battery.Test
Can't find objec...
2006 Sep 08
3
newhidups with APC Smart-UPS 1500
Hello,
I'm using the stable amd64 port of Debian Linux. I installed (the 
latest) nut-2.0.1-4 and nut-usb packages for utilizing an APC Smart-UPS 
1500 USB. I tried "apcupsd" first but "nut" makes an even more 
sophisticated impression on me and has more security options.
I had problems with the newhidups driver. It didn't find a device with 
matching VendorID. And
2019 Jun 11
2
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...t: 8, Size: 8, Value: 0
>    0.029785   Path: UPS.PowerSummary.APCStatusFlag, Type: Input, ReportID: 0x06, Offset: 16, Size: 8, Value: 8
>    0.030618   Path: UPS.PowerSummary.APCStatusFlag, Type: Feature, ReportID: 0x06, Offset: 16, Size: 8, Value: 8
>    0.031914   Path: UPS.PowerSummary.ManufacturerDate, Type: Feature, ReportID: 0x07, Offset: 0, Size: 16, Value: 18290
>    0.033288   Path: UPS.PowerSummary.ConfigVoltage, Type: Feature, ReportID: 0x08, Offset: 0, Size: 16, Value: 12
>    0.034536   Path: UPS.PowerSummary.Voltage, Type: Feature, ReportID: 0x09, Offset: 0, Size: 16, Value: 12.5...
2019 Jun 11
0
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...e: 8, Value: 0
>>   0.029785   Path: UPS.PowerSummary.APCStatusFlag, Type: Input, ReportID: 0x06, Offset: 16, Size: 8, Value: 8
>>   0.030618   Path: UPS.PowerSummary.APCStatusFlag, Type: Feature, ReportID: 0x06, Offset: 16, Size: 8, Value: 8
>>   0.031914   Path: UPS.PowerSummary.ManufacturerDate, Type: Feature, ReportID: 0x07, Offset: 0, Size: 16, Value: 18290
>>   0.033288   Path: UPS.PowerSummary.ConfigVoltage, Type: Feature, ReportID: 0x08, Offset: 0, Size: 16, Value: 12
>>   0.034536   Path: UPS.PowerSummary.Voltage, Type: Feature, ReportID: 0x09, Offset: 0, Size: 16, Value...
2006 Oct 18
2
newhidups with APC Smart-UPS 1500
...Summary.CapacityGranularity2, Type: Feature, Value:
> > 1.000000
> > Path: UPS.PowerSummary.WarningCapacityLimit, Type: Feature, Value:
> > 50.000000
> > Path: UPS.PowerSummary.RemainingCapacityLimit, Type: Feature, Value:
> > 10.000000
> > Path: UPS.PowerSummary.ManufacturerDate, Type: Feature, Value:
> > 12106.000000
> > Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, Value: 
> > 900.000000
> > Path: UPS.PowerSummary.RunTimeToEmpty, Type: Feature, Value:
> > 900.000000
> > Path: UPS.PowerSummary.DelayBeforeShutdown, Type: Feature, V...
2013 Aug 07
1
FreeNAS , NUT and APC BK500EI problem.
...e, Type: Feature, ReportID: 0x1e,
Offset: 0, Size: 16, Value: 302.3
 1.131410 Report[buf]: (2 bytes) => 05
04
 1.131417 Path: UPS.PowerSummary.iDeviceChemistry, Type: Feature,
ReportID: 0x05, Offset: 0, Size: 8, Value: 4
 1.144027 Report[buf]: (3
bytes) => 15 2e 42
 1.144042 Path: UPS.Battery.ManufacturerDate, Type:
Feature, ReportID: 0x15, Offset: 0, Size: 16, Value: 16942
 1.144076
Report[buf]: (4 bytes) => 45 13 14 01
 1.144085 Path:
UPS.Battery.APCBattReplaceDate, Type: Feature, ReportID: 0x45, Offset:
0, Size: 24, Value: 70675
 1.144109 Report[buf]: (3 bytes) => 2c fa 00
1.144118 Path: UPS.O...
2009 Sep 02
6
Selftest intervall, APC Smart-UPS 750 RM
Hello
I recently switched from apcupsd to NUT2.2.2  without 
any troubles.
I tried to figure out how I can configure the self-test
intervall. The command upsrw lists only the variables
battery.charge.low
battery.runtime.low
ups.delay.shutdown
ups.delay.start
The command usbhid-ups -D and the listing under
http://obsvermes.org/cgi-bin/nut/upsstats.cgi?host=apcsmart at localhost&treemode
2020 Sep 03
2
UPS reboots with APC UPS
...ID: 
0x06, Offset: 8, Size: 8, Value: 0
    0.569534	Path: UPS.PowerSummary.APCStatusFlag, Type: Input, ReportID: 
0x06, Offset: 16, Size: 8, Value: 8
    0.569548	Path: UPS.PowerSummary.APCStatusFlag, Type: Feature, 
ReportID: 0x06, Offset: 16, Size: 8, Value: 8
    0.572386	Path: UPS.PowerSummary.ManufacturerDate, Type: Feature, 
ReportID: 0x07, Offset: 0, Size: 16, Value: 19270
    0.577386	Path: UPS.PowerSummary.ConfigVoltage, Type: Feature, 
ReportID: 0x08, Offset: 0, Size: 16, Value: 24
    0.581404	Path: UPS.PowerSummary.Voltage, Type: Feature, ReportID: 
0x09, Offset: 0, Size: 16, Value: 27.09
    0.5...
2016 May 28
2
Powercom INF-800 support
..., Value: 100
    0.123930    Path: UPS.PowerSummary.WarningCapacityLimit, Type: 
Feature, ReportID: 0x0b, Offset: 0, Size: 8, Value: 30
    0.124550    Path: UPS.PowerSummary.RemainingCapacityLimit, Type: 
Feature, ReportID: 0x0c, Offset: 0, Size: 8, Value: 10
    0.125176    Path: UPS.PowerSummary.ManufacturerDate, Type: Feature, 
ReportID: 0x0d, Offset: 0, Size: 16, Value: 17455
    0.125933    Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, 
ReportID: 0x37, Offset: 0, Size: 16, Value: 800
    0.125942    Path: UPS.PowerSummary.RunTimeToEmpty, Type: Feature, 
ReportID: 0x37, Offset: 0, Size: 16, Value:...
2006 Feb 08
2
2.0.3-pre2: Spurious UPS UPS@localhost battery is
Peter Selinger wrote:
> Hm. I need more information, as NUT seems to garble the values even
> before I can see them. I am not so worried about the date and
> temperatures (although, strangely, the battery replacement date
> appears to be Sept 25, 2001, which makes no sense). But the voltage is
> definitely important.
>
> [...] 
>   
Thanks Peter - I'll send the new
2006 Aug 02
1
nut-usb fink version
...D> 00 00 9C F3 00 03 10 D2
> > hu_find_infoval: searching for value =3D 0
> >
> > -> String: ? (len =3D 1/4)
> > hu_find_infoval: found ? (value: 0)
> >
> > entering string_to_path()
> > Looking up UPS
> > Looking up Battery
> > Looking up ManufacturerDate
> > Report : (8 bytes) =3D> 00 00 9C F3 00 03 10 D2
> > hu_find_infoval: searching for value =3D 0
> >
> > hu_find_infoval: found not set (value: 0)
> >
> > entering string_to_path()
> > Looking up UPS
> > Looking up Battery
> > Looking up AP...
2006 Nov 11
1
Help with newhidups subdriver for Dynex UPS
...e: 0.000000
Path: UPS.Output.Overload, Type: Feature, Value: 0.000000
Path: UPS.Output., Type: Feature
Path: UPS.Output.ConfigActivePower, Type: Feature, Value: 450.000000
Can't find object UPS.Battery.ConfigVoltage
Can't find object UPS.Battery.Temperature
Can't find object UPS.Battery.ManufacturerDate
Can't find object UPS.PowerSummary.APCBattReplaceDate
Can't find object UPS.Battery.APCBattReplaceDate
Can't find object UPS.PowerSummary.DelayBeforeShutdown
Can't find object UPS.APCGeneralCollection.APCDelayBeforeShutdown
Can't find object UPS.Battery.Test
Can't find objec...
2009 Mar 13
7
Weird Load and Battery Temp Readings
...000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000
Path: UPS.PowerSummary.iDeviceChemistry, Type: Feature, ReportID: 0x05, 
Offset: 0, Size: 8, Value: 4.000000
Path: UPS.Battery.ManufacturerDate, Type: Feature, ReportID: 0x15, 
Offset: 0, Size: 16, Value: 14533.000000
Path: UPS.Battery.APCBattReplaceDate, Type: Feature, ReportID: 0x45, 
Offset: 0, Size: 24, Value: 599297.000000
Path: UPS.Output.PercentLoad, Type: Feature, ReportID: 0x2c, Offset: 0, 
Size: 16, Value: 
2000000000000000000000...
2005 Oct 04
0
Problems connecting to APC/Smart-UPS 3000 RM
...llChargeCapacity
Path: UPS.PowerSummary.RemainingCapacity
Path: UPS.PowerSummary.RemainingCapacity
Path: UPS.PowerSummary.CapacityGranularity1
Path: UPS.PowerSummary.CapacityGranularity2
Path: UPS.PowerSummary.WarningCapacityLimit
Path: UPS.PowerSummary.RemainingCapacityLimit
Path: UPS.PowerSummary.ManufacturerDate
Path: UPS.PowerSummary.RunTimeToEmpty
Path: UPS.PowerSummary.RunTimeToEmpty
Path: UPS.PowerSummary.DelayBeforeShutdown
Path: UPS.PowerSummary.DelayBeforeReboot
Path: UPS.PowerSummary.RemainingTimeLimit
Path: UPS.PowerSummary.RemainingTimeLimit
Path: UPS.PowerSummary.ConfigVoltage
Path: UPS.PowerSum...
2012 Apr 09
2
libusb_get_report: Unknown error
..., ReportID: 0x0f, Offset: 0, Size: 8, Value: 50
   0.890489	Report[get]: (2 bytes) => 11 0a
   0.890514	Path: UPS.PowerSummary.RemainingCapacityLimit, Type: Feature, ReportID: 0x11, Offset: 0, Size: 8, Value: 10
   0.896475	Report[get]: (3 bytes) => 09 a6 34
   0.896496	Path: UPS.PowerSummary.ManufacturerDate, Type: Feature, ReportID: 0x09, Offset: 0, Size: 16, Value: 13478
   0.902481	Report[get]: (3 bytes) => 0d 00 00
   0.902491	Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, ReportID: 0x0d, Offset: 0, Size: 16, Value: 0
   0.902496	Report[buf]: (3 bytes) => 0d 00 00
   0.902503	Path: UPS.P...
2015 Jan 09
0
persistent "low battery" condition
On Jan 8, 2015, at 11:43 PM, Graham Menhennitt <graham at menhennitt.com.au> wrote:
> Hello Nutters,
> 
> I'm running nut 2.7.2 on FreeBSD 10-stable (via the FreeBSD port) with an APC Back-UPS CS 350 connected via USB. I get persistent (every few minutes) messages logged "battery is low" but I don't understand why. I don't think it's for the reason
2015 Jan 12
2
persistent "low battery" condition
...0x1f, Offset: 0, Size: 16, Value: 12
 771.669091     Path: UPS.Battery.Temperature, Type: Feature, ReportID:
0x1e, Offset: 0, Size: 16, Value: 302.3
 771.680018     Path: UPS.PowerSummary.iDeviceChemistry, Type: Feature,
ReportID: 0x05, Offset: 0, Size: 8, Value: 4
 771.733652     Path: UPS.Battery.ManufacturerDate, Type: Feature,
ReportID: 0x15, Offset: 0, Size: 16, Value: 12935
 771.744709     Path: UPS.Battery.APCBattReplaceDate, Type: Feature,
ReportID: 0x45, Offset: 0, Size: 24, Value: 263941
 771.764677     Path: UPS.Output.PercentLoad, Type: Feature, ReportID:
0x2c, Offset: 0, Size: 16, Value: 73
 771....