search for: manufacturerdate

Displaying 20 results from an estimated 25 matches for "manufacturerdate".

2005 Aug 26
0
NUT patches
...Before fixing the HIDParser bug: HIDDumpTree... Path: UPS.PowerSummary.iSerialNumber Path: UPS.PowerSummary.iDeviceChemistry Path: UPS.PowerSummary.iOEMInformation Path: UPS.PowerSummary.Rechargeable Path: UPS.PowerSummary.APCStatusFlag Path: UPS.PowerSummary.APCStatusFlag Path: UPS.PowerSummary.ManufacturerDate Path: UPS.PowerSummary.ConfigVoltage Path: UPS.PowerSummary.Voltage Path: UPS.PowerSummary.iManufacturer Path: UPS.PowerSummary.CapacityMode Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.RunTimeToEmpty...
2005 Jul 22
1
Another HID USB UPS
...an UPS: APC/Back-UPS ES 650 FW:818.w1.D USB FW:w1 Path: UPS.PowerSummary.iSerialNumber Path: UPS.PowerSummary.iDeviceChemistry Path: UPS.PowerSummary.iOEMInformation Path: UPS.PowerSummary.Rechargeable Path: UPS.PowerSummary.APCStatusFlag Path: UPS.PowerSummary.APCStatusFlag Path: UPS.PowerSummary.ManufacturerDate Path: UPS.PowerSummary.ConfigVoltage Path: UPS.PowerSummary.Voltage Path: UPS.PowerSummary.iManufacturer Path: UPS.PowerSummary.CapacityMode Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.RunTimeToEmpty...
2005 Aug 02
0
newhidups for APC Back-UPS ES 650
...USB FW:w1 ............. output heavily reduced! Path: UPS.PowerSummary.iSerialNumber Path: UPS.PowerSummary.iDeviceChemistry Path: UPS.PowerSummary.iOEMInformation Path: UPS.PowerSummary.Rechargeable Path: UPS.PowerSummary.APCStatusFlag Path: UPS.PowerSummary.APCStatusFlag Path: UPS.PowerSummary.ManufacturerDate Path: UPS.PowerSummary.ConfigVoltage Path: UPS.PowerSummary.Voltage Path: UPS.PowerSummary.iManufacturer Path: UPS.PowerSummary.CapacityMode Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.RunTimeToEmpty...
2007 Jan 26
1
newhidups output for Geek Squad GS1285U
...e: 0.000000 Path: UPS.Output.Overload, Type: Feature, Value: 0.000000 Path: UPS.Output., Type: Feature Path: UPS.Output.ConfigActivePower, Type: Feature, Value: 238.000000 Can't find object UPS.Battery.ConfigVoltage Can't find object UPS.Battery.Temperature Can't find object UPS.Battery.ManufacturerDate Can't find object UPS.PowerSummary.APCBattReplaceDate Can't find object UPS.Battery.APCBattReplaceDate Can't find object UPS.PowerSummary.DelayBeforeShutdown Can't find object UPS.APCGeneralCollection.APCDelayBeforeShutdown Can't find object UPS.Battery.Test Can't find objec...
2006 Sep 08
3
newhidups with APC Smart-UPS 1500
Hello, I'm using the stable amd64 port of Debian Linux. I installed (the latest) nut-2.0.1-4 and nut-usb packages for utilizing an APC Smart-UPS 1500 USB. I tried "apcupsd" first but "nut" makes an even more sophisticated impression on me and has more security options. I had problems with the newhidups driver. It didn't find a device with matching VendorID. And
2019 Jun 11
2
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...t: 8, Size: 8, Value: 0 > 0.029785 Path: UPS.PowerSummary.APCStatusFlag, Type: Input, ReportID: 0x06, Offset: 16, Size: 8, Value: 8 > 0.030618 Path: UPS.PowerSummary.APCStatusFlag, Type: Feature, ReportID: 0x06, Offset: 16, Size: 8, Value: 8 > 0.031914 Path: UPS.PowerSummary.ManufacturerDate, Type: Feature, ReportID: 0x07, Offset: 0, Size: 16, Value: 18290 > 0.033288 Path: UPS.PowerSummary.ConfigVoltage, Type: Feature, ReportID: 0x08, Offset: 0, Size: 16, Value: 12 > 0.034536 Path: UPS.PowerSummary.Voltage, Type: Feature, ReportID: 0x09, Offset: 0, Size: 16, Value: 12.5...
2019 Jun 11
0
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...e: 8, Value: 0 >> 0.029785 Path: UPS.PowerSummary.APCStatusFlag, Type: Input, ReportID: 0x06, Offset: 16, Size: 8, Value: 8 >> 0.030618 Path: UPS.PowerSummary.APCStatusFlag, Type: Feature, ReportID: 0x06, Offset: 16, Size: 8, Value: 8 >> 0.031914 Path: UPS.PowerSummary.ManufacturerDate, Type: Feature, ReportID: 0x07, Offset: 0, Size: 16, Value: 18290 >> 0.033288 Path: UPS.PowerSummary.ConfigVoltage, Type: Feature, ReportID: 0x08, Offset: 0, Size: 16, Value: 12 >> 0.034536 Path: UPS.PowerSummary.Voltage, Type: Feature, ReportID: 0x09, Offset: 0, Size: 16, Value...
2006 Oct 18
2
newhidups with APC Smart-UPS 1500
...Summary.CapacityGranularity2, Type: Feature, Value: > > 1.000000 > > Path: UPS.PowerSummary.WarningCapacityLimit, Type: Feature, Value: > > 50.000000 > > Path: UPS.PowerSummary.RemainingCapacityLimit, Type: Feature, Value: > > 10.000000 > > Path: UPS.PowerSummary.ManufacturerDate, Type: Feature, Value: > > 12106.000000 > > Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, Value: > > 900.000000 > > Path: UPS.PowerSummary.RunTimeToEmpty, Type: Feature, Value: > > 900.000000 > > Path: UPS.PowerSummary.DelayBeforeShutdown, Type: Feature, V...
2013 Aug 07
1
FreeNAS , NUT and APC BK500EI problem.
...e, Type: Feature, ReportID: 0x1e, Offset: 0, Size: 16, Value: 302.3 1.131410 Report[buf]: (2 bytes) => 05 04 1.131417 Path: UPS.PowerSummary.iDeviceChemistry, Type: Feature, ReportID: 0x05, Offset: 0, Size: 8, Value: 4 1.144027 Report[buf]: (3 bytes) => 15 2e 42 1.144042 Path: UPS.Battery.ManufacturerDate, Type: Feature, ReportID: 0x15, Offset: 0, Size: 16, Value: 16942 1.144076 Report[buf]: (4 bytes) => 45 13 14 01 1.144085 Path: UPS.Battery.APCBattReplaceDate, Type: Feature, ReportID: 0x45, Offset: 0, Size: 24, Value: 70675 1.144109 Report[buf]: (3 bytes) => 2c fa 00 1.144118 Path: UPS.O...
2009 Sep 02
6
Selftest intervall, APC Smart-UPS 750 RM
Hello I recently switched from apcupsd to NUT2.2.2 without any troubles. I tried to figure out how I can configure the self-test intervall. The command upsrw lists only the variables battery.charge.low battery.runtime.low ups.delay.shutdown ups.delay.start The command usbhid-ups -D and the listing under http://obsvermes.org/cgi-bin/nut/upsstats.cgi?host=apcsmart at localhost&treemode
2020 Sep 03
2
UPS reboots with APC UPS
...ID: 0x06, Offset: 8, Size: 8, Value: 0 0.569534 Path: UPS.PowerSummary.APCStatusFlag, Type: Input, ReportID: 0x06, Offset: 16, Size: 8, Value: 8 0.569548 Path: UPS.PowerSummary.APCStatusFlag, Type: Feature, ReportID: 0x06, Offset: 16, Size: 8, Value: 8 0.572386 Path: UPS.PowerSummary.ManufacturerDate, Type: Feature, ReportID: 0x07, Offset: 0, Size: 16, Value: 19270 0.577386 Path: UPS.PowerSummary.ConfigVoltage, Type: Feature, ReportID: 0x08, Offset: 0, Size: 16, Value: 24 0.581404 Path: UPS.PowerSummary.Voltage, Type: Feature, ReportID: 0x09, Offset: 0, Size: 16, Value: 27.09 0.5...
2016 May 28
2
Powercom INF-800 support
..., Value: 100 0.123930 Path: UPS.PowerSummary.WarningCapacityLimit, Type: Feature, ReportID: 0x0b, Offset: 0, Size: 8, Value: 30 0.124550 Path: UPS.PowerSummary.RemainingCapacityLimit, Type: Feature, ReportID: 0x0c, Offset: 0, Size: 8, Value: 10 0.125176 Path: UPS.PowerSummary.ManufacturerDate, Type: Feature, ReportID: 0x0d, Offset: 0, Size: 16, Value: 17455 0.125933 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, ReportID: 0x37, Offset: 0, Size: 16, Value: 800 0.125942 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Feature, ReportID: 0x37, Offset: 0, Size: 16, Value:...
2006 Feb 08
2
2.0.3-pre2: Spurious UPS UPS@localhost battery is
Peter Selinger wrote: > Hm. I need more information, as NUT seems to garble the values even > before I can see them. I am not so worried about the date and > temperatures (although, strangely, the battery replacement date > appears to be Sept 25, 2001, which makes no sense). But the voltage is > definitely important. > > [...] > Thanks Peter - I'll send the new
2006 Aug 02
1
nut-usb fink version
...D> 00 00 9C F3 00 03 10 D2 > > hu_find_infoval: searching for value =3D 0 > > > > -> String: ? (len =3D 1/4) > > hu_find_infoval: found ? (value: 0) > > > > entering string_to_path() > > Looking up UPS > > Looking up Battery > > Looking up ManufacturerDate > > Report : (8 bytes) =3D> 00 00 9C F3 00 03 10 D2 > > hu_find_infoval: searching for value =3D 0 > > > > hu_find_infoval: found not set (value: 0) > > > > entering string_to_path() > > Looking up UPS > > Looking up Battery > > Looking up AP...
2006 Nov 11
1
Help with newhidups subdriver for Dynex UPS
...e: 0.000000 Path: UPS.Output.Overload, Type: Feature, Value: 0.000000 Path: UPS.Output., Type: Feature Path: UPS.Output.ConfigActivePower, Type: Feature, Value: 450.000000 Can't find object UPS.Battery.ConfigVoltage Can't find object UPS.Battery.Temperature Can't find object UPS.Battery.ManufacturerDate Can't find object UPS.PowerSummary.APCBattReplaceDate Can't find object UPS.Battery.APCBattReplaceDate Can't find object UPS.PowerSummary.DelayBeforeShutdown Can't find object UPS.APCGeneralCollection.APCDelayBeforeShutdown Can't find object UPS.Battery.Test Can't find objec...
2009 Mar 13
7
Weird Load and Battery Temp Readings
...000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000.000000 Path: UPS.PowerSummary.iDeviceChemistry, Type: Feature, ReportID: 0x05, Offset: 0, Size: 8, Value: 4.000000 Path: UPS.Battery.ManufacturerDate, Type: Feature, ReportID: 0x15, Offset: 0, Size: 16, Value: 14533.000000 Path: UPS.Battery.APCBattReplaceDate, Type: Feature, ReportID: 0x45, Offset: 0, Size: 24, Value: 599297.000000 Path: UPS.Output.PercentLoad, Type: Feature, ReportID: 0x2c, Offset: 0, Size: 16, Value: 2000000000000000000000...
2005 Oct 04
0
Problems connecting to APC/Smart-UPS 3000 RM
...llChargeCapacity Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.RemainingCapacity Path: UPS.PowerSummary.CapacityGranularity1 Path: UPS.PowerSummary.CapacityGranularity2 Path: UPS.PowerSummary.WarningCapacityLimit Path: UPS.PowerSummary.RemainingCapacityLimit Path: UPS.PowerSummary.ManufacturerDate Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.DelayBeforeShutdown Path: UPS.PowerSummary.DelayBeforeReboot Path: UPS.PowerSummary.RemainingTimeLimit Path: UPS.PowerSummary.RemainingTimeLimit Path: UPS.PowerSummary.ConfigVoltage Path: UPS.PowerSum...
2012 Apr 09
2
libusb_get_report: Unknown error
..., ReportID: 0x0f, Offset: 0, Size: 8, Value: 50 0.890489 Report[get]: (2 bytes) => 11 0a 0.890514 Path: UPS.PowerSummary.RemainingCapacityLimit, Type: Feature, ReportID: 0x11, Offset: 0, Size: 8, Value: 10 0.896475 Report[get]: (3 bytes) => 09 a6 34 0.896496 Path: UPS.PowerSummary.ManufacturerDate, Type: Feature, ReportID: 0x09, Offset: 0, Size: 16, Value: 13478 0.902481 Report[get]: (3 bytes) => 0d 00 00 0.902491 Path: UPS.PowerSummary.RunTimeToEmpty, Type: Input, ReportID: 0x0d, Offset: 0, Size: 16, Value: 0 0.902496 Report[buf]: (3 bytes) => 0d 00 00 0.902503 Path: UPS.P...
2015 Jan 09
0
persistent "low battery" condition
On Jan 8, 2015, at 11:43 PM, Graham Menhennitt <graham at menhennitt.com.au> wrote: > Hello Nutters, > > I'm running nut 2.7.2 on FreeBSD 10-stable (via the FreeBSD port) with an APC Back-UPS CS 350 connected via USB. I get persistent (every few minutes) messages logged "battery is low" but I don't understand why. I don't think it's for the reason
2015 Jan 12
2
persistent "low battery" condition
...0x1f, Offset: 0, Size: 16, Value: 12 771.669091 Path: UPS.Battery.Temperature, Type: Feature, ReportID: 0x1e, Offset: 0, Size: 16, Value: 302.3 771.680018 Path: UPS.PowerSummary.iDeviceChemistry, Type: Feature, ReportID: 0x05, Offset: 0, Size: 8, Value: 4 771.733652 Path: UPS.Battery.ManufacturerDate, Type: Feature, ReportID: 0x15, Offset: 0, Size: 16, Value: 12935 771.744709 Path: UPS.Battery.APCBattReplaceDate, Type: Feature, ReportID: 0x45, Offset: 0, Size: 24, Value: 263941 771.764677 Path: UPS.Output.PercentLoad, Type: Feature, ReportID: 0x2c, Offset: 0, Size: 16, Value: 73 771....