search for: lowbattwarn

Displaying 4 results from an estimated 4 matches for "lowbattwarn".

2011 Jul 19
2
KIN-1500AP RM + Windows 2008 64-bit Standard R2 SP1 (nut 2.6.1)
...AG ONLINE SYSLOG+WALL+EXEC NOTIFYFLAG ONBATT SYSLOG+WALL+EXEC NOTIFYFLAG LOWBATT SYSLOG+WALL+EXEC RBWARNTIME 43200 NOCOMMWARNTIME 300 FINALDELAY 5 upssched.conf: * * CMDSCRIPT /bin/upssched-cmd AT ONBATT * START-TIMER onbattwarn 10 AT ONLINE * CANCEL-TIMER onbattwarn AT LOWBATT * EXECUTE lowbattwarn AT ONBATT * START-TIMER timeshutdown 100 AT ONLINE * CANCEL-TIMER timeshutdown After start I can see couple neutral events: upsd.exe - listening on 192.168.1.2 port 3493. upsd.exe - User monuser at 192.168.1.2 logged into UPS [KIN1500]. Also, there are a lot of errors, such as "upsmon -...
2011 Jun 08
2
Misconfiguration of Windows MSI installer 2.6.0-1 with my Powerware 5115 connected via USB port
...YFLAG ONLINE SYSLOG+WALL+EXEC NOTIFYFLAG ONBATT SYSLOG+WALL+EXEC NOTIFYFLAG LOWBATT SYSLOG+WALL+EXEC RBWARNTIME 43200 NOCOMMWARNTIME 300 FINALDELAY 5 *upssched.conf:* CMDSCRIPT /bin/upssched-cmd AT ONBATT * START-TIMER onbattwarn 10 AT ONLINE * CANCEL-TIMER onbattwarn AT LOWBATT * EXECUTE lowbattwarn AT ONBATT * START-TIMER timeshutdown 100 AT ONLINE * CANCEL-TIMER timeshutdown There are huge count of windows events such as "upsmon - Poll UPS [ PW5115 at 192.168.1.12] failed - Data stale." Can anyone help me to get right configs? Thanks -------------- next part -------------- An...
2013 Jun 28
2
How to Simulate UPS on battery?
...using 10 seconds to reduce the testing time) Here's the upssched.conf for S2: $ cat /usr/local/etc/nut/upssched.conf CMDSCRIPT /usr/local/sbin/upssched-cmd.sh PIPEFN /var/run/upssched/upssched.pipe LOCKFN /var/run/upssched/upssched.lock AT LOWBATT * START-TIMER lowbattwarn 1 AT ONBATT * START-TIMER onbattwarn 10 AT ONLINE * CANCEL-TIMER onbattwarn And here is the upsmon.conf on S2: $ cat /usr/local/etc/nut/upssched.conf RUN_AS_USER _ups MONITOR PW5125 at s1.EXAMPLE.COM 1 monuser tHEuNSPOKENpSWD slave MIN...
2017 May 14
2
[HCL] Cyber Power Systems CP1500AVRLCDa supported by usbhid-ups
...60 on the number of seconds given by the command. That is why the request for a 59 second delay resulted in no delay at all. === I see the same behavior with this model. The following command excerpts from the upssched.conf file work as expected: AT LOWBATT ups2 at 127.0.0.1 START-TIMER ups2-lowbattwarn 1 AT ONBATT ups2 at 127.0.0.1 START-TIMER ups2-onbatt-early 60 AT ONBATT ups2 at 127.0.0.1 START-TIMER ups2-onbatt-final 180 AT ONBATT ups2 at 127.0.0.1 EXECUTE ups2-start-batt AT ONLINE ups2 at 127.0.0.1 CANCEL-TIMER ups2-onbatt-early AT ONLINE ups2 at 127.0.0.1 CANCEL-TIM...