Displaying 20 results from an estimated 23 matches for "logmin".
Did you mean:
login
2009 Mar 13
7
Weird Load and Battery Temp Readings
I've acquired and installed NUT 2.4.1 on a D-Link DNS323 NAS. With
exception of Load and Battery Temp readings all works well. A upsc
ups at localhost command returns;
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 50
battery.date: 2001/09/25
battery.mfr.date: 2008/06/05
battery.runtime: 2122
battery.runtime.low: 120
battery.temperature: 3022999999999998800
battery.type:
2012 Mar 21
5
Socomec sicon Netys 2000 PR ups USb driver for ubuntu
Hello i tried to connect my netys 2000 pr ups to ubuntu 11.10 and i have a problem connecting it. After readin a few post i realized to dianosse the connection.
I need help resolving the connextion issue
So here is the response to??/lib/nut/usbhid-ups -u root -DDDDD -a netys:
Network UPS Tools - Generic HID driver 0.35 (2.6.1)
USB communication driver 0.31
? ?0.000000 ? ? send_to_all: SETINFO
2014 Feb 25
0
Setting UPS values can be confusing
...UPS -> 00840004
0.624002 hid_lookup_usage: PowerSummary -> 00840024
0.624002 hid_lookup_usage: RemainingCapacityLimit -> 00850029
0.624002 string_to_path: depth = 3
0.624002 Report[buf]: (2 bytes) => 11 0a
0.624002 PhyMax = 0, PhyMin = 0, LogMax = 100, LogMin = 1
0.624002 Unit = 00000000, UnitExp = 0
0.624002 Exponent = 0
0.624002 Path: UPS.PowerSummary.RemainingCapacityLimit, Type:
Feature, ReportID: 0x11, Offset: 0, Size: 8, Value: 10
0.624002 send_to_all: SETINFO battery.charge.low "10"
0.624002 send_to_a...
2023 Nov 04
2
EPYC Quantum 1500va
...server...
[17:19:13] INFO: Generating /etc/nut/upsd.users...
[17:19:14] INFO: Configuring user: Raul
[17:19:17] INFO: Password is NOT in the Have I Been Pwned database! Nice!
[17:19:20] INFO: Configuring Device named EPYC...
[17:19:21] INFO: Starting the UPS drivers...
HIDParse: LogMax is less than LogMin. Vendor HID report descriptor may
be incorrect; interpreting LogMax -1 as 65535 in ReportID: 0x0f
Network UPS Tools - Generic HID driver 0.47 (2.8.0)
HIDParse: LogMax is less than LogMin. Vendor HID report descriptor may
be incorrect; interpreting LogMax -1 as 255 in ReportID: 0x12
HIDParse: LogMax...
2024 Nov 01
1
NUT 2.8.1-3 " Can't claim USB device [051d:0002]@0/0: Entity not found" using usbhid-ups
...emory: 1.0M (peak: 1.9M)
CPU: 43.317s
CGroup:
/system.slice/system-nut\x2ddriver.slice/nut-driver at apcupskelder.service
??1141 /lib/nut/usbhid-ups -a apcupskelder
nov 01 01:26:40 MinipcLG2 nut-driver at apcupskelder[1068]: HIDParse:
LogMax is less than LogMin. Vendor HID report descriptor may be incorrect;
interpreting >
nov 01 01:26:40 MinipcLG2 nut-driver at apcupskelder[1068]: HIDParse:
LogMax is less than LogMin. Vendor HID report descriptor may be incorrect;
interpreting >
nov 01 01:26:40 MinipcLG2 nut-driver at apcupskelder[10...
2017 May 11
4
APC Back-UPS XS 1500G says "No battery"
I have a new-ish APC Back-UPS XS 1500G connected via USB. It's giving me
a "ups.alarm: No battery installed!" error. I also installed and
configured apcupsd to give that a try and it's giving me the same error.
I suspect this is a driver problem because while NUT claims the battery
isn't plugged in, it's giving me battery runtime/charge info. Both can't
be valid
2024 Nov 01
1
NUT 2.8.1-3 " Can't claim USB device [051d:0002]@0/0: Entity not found" using usbhid-ups
...d Oct 30 10:27:32
> 2024):
>
> Communications with UPS apcupskelder at localhost lost
>
>
> Bericht aan allen van root at MinipcLG2 (somewhere) (Wed Oct 30 10:27:32
> 2024):
>
> Communications with UPS apcupskelder at localhost lost
>
> HIDParse: LogMax is less than LogMin. Vendor HID report descriptor may be
> incorrect; interpreting LogMax -1 as 255 in ReportID: 0x0c
> HIDParse: LogMax is less than LogMin. Vendor HID report descriptor may be
> incorrect; interpreting LogMax -1 as 255 in ReportID: 0x22
> HIDParse: LogMax is less than LogMin. Vendor HID r...
2014 Oct 10
1
Return on experience with an Emerson/Liebert GXT3
Hi
On 10/06/2014 03:04 PM, Charles Lepple wrote:> I think I see what is going on.
>
>???? 0.368670??? Report[buf]: (5 bytes) => 05 4e 00 48 00
>???? 0.368698??? PhyMax = 0, PhyMin = 0, LogMax = 1, LogMin = 0
>???? 0.368723??? Unit = 00000000, UnitExp = 0
>???? 0.368747??? Exponent = 0
>???? 0.368776??? Path: UPS.PowerSummary.Voltage, Type: Feature, ReportID: 0x05, Offset: 0, Size: 16, Value: 0
>???? 0.368805??? Input/OutputVoltage = 0 -> assuming correction factor = 1e+07
>
>...
2017 May 12
0
APC Back-UPS XS 1500G says "No battery"
...lookup_path: 008500d1 -> BatteryPresent
> 0.571446 Path: UPS.PowerSummary.PresentStatus.BatteryPresent, Type: Input, ReportID: 0x16, Offset: 3, Size: 1, Value: 0
> 0.571449 Report[buf]: (5 bytes) => 16 04 00 00 00
> 0.571451 PhyMax = 0, PhyMin = 0, LogMax = 1, LogMin = 0
> 0.571453 Unit = 00000000, UnitExp = 0
> 0.571455 Exponent = 0
> 0.571457 hid_lookup_path: 00840004 -> UPS
> 0.571459 hid_lookup_path: 00840024 -> PowerSummary
> 0.571461 hid_lookup_path: 00840002 -> PresentStatus
> 0.57146...
2015 Mar 13
0
Problems with NUT 2.7.2 on CentOS 7 and using the Mini-Box OpenUPS
...in upsc.
>
> And if I run upsd with high level of debug, after working OK for a while, I see these ?broken pipe? messages :
>
> 0.419974 Entering libusb_get_report
> 0.421967 Report[get]: (4 bytes) => 60 c4 ff 3b
> 0.422056 PhyMax = 0, PhyMin = 0, LogMax = 16777215, LogMin = 0
> 0.422069 Unit = 00001001, UnitExp = 0
> 0.422080 Exponent = 0
> 0.422093 hid_lookup_path: 00840004 -> UPS
> 0.422107 hid_lookup_path: 00840024 -> PowerSummary
> 0.422121 hid_lookup_path: 00850068 -> RunTimeToEmpty
> 0.422146 Path: UPS.PowerSummary....
2006 May 22
3
USB UPS and FreeBSD
I am looking at the newhid driver for this Pulsar EXtreme here but it gives
odd results, for example there is no status variable :)
eg
debug level is '2'
Checking device (0463/FFFF) (/dev/usb0//dev/ugen0)
- VendorID: 0463
- ProductID: ffff
- Manufacturer: unknown
- Product: unknown
- Serial Number: unknown
- Bus: /dev/usb0
Trying to match device
Device matches
HID descriptor retrieved
2013 Feb 08
0
Very long delay for shutdown.restart on usbhid-ups powercom
...th
uncorrect parameters:
55.348163 instcmd(shutdown.return, 30)
55.348205 powercom_shutdown_nuf: value = 30, command = 5E00
55.348218 hu_find_valinfo: found 24064 (value: 30)
55.348229 Unit = 00000000, UnitExp = 0
55.348239 Exponent = 0
55.348249 PhyMax = 0, PhyMin = 0, LogMax = 65535, LogMin = 0
55.348920 Report[set]: (3 bytes) => 0f 00 5e
55.348945 Set report succeeded
55.348956 instcmd: SUCCEED
Value 30 is converted to 24064, and this seems the delay that is
configured on the device to complete its shutdown:
[...]
56.358009 Path: UPS.PowerSummary.DelayBeforeShutdown, Type...
2014 Oct 06
1
Return on experience with an Emerson/Liebert GXT3
Hi
On 10/03/2014 03:42 PM, Charles Lepple wrote:> On Oct 3, 2014, at 7:50 AM, paul.chavent at fnac.net wrote:
>
>
> This is what I was referring to (from the belkin-hid log):
>
>???? 1.325782??? Report[buf]: (5 bytes) => 05 53 00 48 00
>???? 1.325799??? Path: UPS.PowerSummary.ConfigVoltage, Type: Feature, ReportID: 0x05, Offset: 16, Size: 16, Value: 0
>????
2024 Oct 30
1
NUT 2.8.1-3 " Can't claim USB device [051d:0002]@0/0: Entity not found" using usbhid-ups
...ht aan allen van root at MinipcLG2 (somewhere) (Wed Oct 30 10:27:32 2024):
Communications with UPS apcupskelder at localhost lost
Bericht aan allen van root at MinipcLG2 (somewhere) (Wed Oct 30 10:27:32 2024):
Communications with UPS apcupskelder at localhost lost
HIDParse: LogMax is less than LogMin. Vendor HID report descriptor may be
incorrect; interpreting LogMax -1 as 255 in ReportID: 0x0c
HIDParse: LogMax is less than LogMin. Vendor HID report descriptor may be
incorrect; interpreting LogMax -1 as 255 in ReportID: 0x22
HIDParse: LogMax is less than LogMin. Vendor HID report descriptor may...
2024 Mar 25
0
There is no voltage information
...kup_usage: UPS -> 00840004
> 0.278621 hid_lookup_usage: Output -> 0084001c
> 0.278769 hid_lookup_usage: Voltage -> 00840030
> 0.278913 string_to_path: depth = 3
> 0.279025 Report[buf]: (3 bytes) => 2b 9e 08
> 0.279133 PhyMax = 0, PhyMin = 0, LogMax = 65535, LogMin = 0
> 0.279240 Unit = 00f0d121, UnitExp = -1
> 0.279304 Exponent = -8
> 0.279412 Path: UPS.Output.Voltage, Type: Feature, ReportID: 0x2b,
> Offset: 0, Size: 16, Value: 2.206e-05
> 0.279523 Input/OutputVoltage = 2.206e-05 -> assuming correction factor
> = 1e+07
>...
2024 Mar 25
0
There is no voltage information
...kup_usage: UPS -> 00840004
> 0.278621 hid_lookup_usage: Output -> 0084001c
> 0.278769 hid_lookup_usage: Voltage -> 00840030
> 0.278913 string_to_path: depth = 3
> 0.279025 Report[buf]: (3 bytes) => 2b 9e 08
> 0.279133 PhyMax = 0, PhyMin = 0, LogMax = 65535, LogMin = 0
> 0.279240 Unit = 00f0d121, UnitExp = -1
> 0.279304 Exponent = -8
> 0.279412 Path: UPS.Output.Voltage, Type: Feature, ReportID: 0x2b,
> Offset: 0, Size: 16, Value: 2.206e-05
> 0.279523 Input/OutputVoltage = 2.206e-05 -> assuming correction factor
> = 1e+07
>...
2016 May 28
0
Powercom INF-800 support
...wn.return, [NULL])
> 0.145767 powercom_shutdown_nuf: value = (null), command = 5400
> 0.145770 hu_find_valinfo: found 21504 (value: (null))
> 0.145773 Unit = 00000000, UnitExp = 0
> 0.145775 Exponent = 0
> 0.145778 PhyMax = 0, PhyMin = 0, LogMax = 65535, LogMin = 0
> 0.155952 Report[set]: (3 bytes) => 0f 00 54
> 0.155981 Set report succeeded
> 0.155986 instcmd: SUCCEED
>
When you attempted the shutdown.return, was the UPS powered or on battery?
My older Tripplite SMART2200VS won't shutdown.return unless it is running...
2016 May 28
1
Powercom INF-800 support
...gt; 0.145767 powercom_shutdown_nuf: value = (null), command = 5400
> 0.145770 hu_find_valinfo: found 21504 (value: (null))
> 0.145773 Unit = 00000000, UnitExp = 0
> 0.145775 Exponent = 0
> 0.145778 PhyMax = 0, PhyMin = 0, LogMax = 65535, LogMin = 0
> 0.155952 Report[set]: (3 bytes) => 0f 00 54
> 0.155981 Set report succeeded
> 0.155986 instcmd: SUCCEED
>
>
> When you attempted the shutdown.return, was the UPS powered or on
> battery? My older Tripplite SMART2200VS won't shutdown....
2015 Mar 13
3
Problems with NUT 2.7.2 on CentOS 7 and using the Mini-Box OpenUPS
I?m a new user of NUT and the OpenUPS - in the past I?ve used APC hardware and apcupsd on Centos 6.
I?ve built NUT 2.7.2 from source but used the OpenUPS HID driver v0.4 that?s in github. I?m using firmware version 1.5 on the openups which is the latest published version; I?ve also tried 1.7 which Mini-box sent to me but reverted to the published version. Their support seems a bit slow!
I?ve got
2016 May 28
2
Powercom INF-800 support
...63 instcmd(shutdown.return, [NULL])
0.145767 powercom_shutdown_nuf: value = (null), command = 5400
0.145770 hu_find_valinfo: found 21504 (value: (null))
0.145773 Unit = 00000000, UnitExp = 0
0.145775 Exponent = 0
0.145778 PhyMax = 0, PhyMin = 0, LogMax = 65535, LogMin = 0
0.155952 Report[set]: (3 bytes) => 0f 00 54
0.155981 Set report succeeded
0.155986 instcmd: SUCCEED
Every 2 sec driver outputs the following:
10.254942 upsdrv_updateinfo...
10.507035 libusb_get_interrupt: Connection timed out
10.507054 Got 0 HID object...