search for: linev

Displaying 6 results from an estimated 6 matches for "linev".

Did you mean: line
2005 Jul 09
1
apcsmart varibles
...my UPS: # /usr/local/sbin/apcaccess status DATE : Sat Jul 09 12:56:41 CDT 2005 HOSTNAME : homer RELEASE : 3.8.6 UPSNAME : UPS_IDEN CABLE : Custom Cable Smart MODEL : APC Smart-UPS 900 UPSMODE : Net Master STARTTIME: Sat Jul 09 12:55:48 CDT 2005 SHARE : NetworkUPS STATUS : ONLINE LINEV : 112.8 Volts LOADPCT : 97.7 Percent Load Capacity BCHARGE : 100.0 Percent TIMELEFT : 8.0 Minutes MBATTCHG : 5 Percent MINTIMEL : 3 Minutes MAXTIME : 0 Seconds MAXLINEV : 113.4 Volts MINLINEV : 112.2 Volts OUTPUTV : 112.8 Volts SENSE : High DWAKE : 000 Seconds DSHUTD : 020 Seconds...
2017 May 11
4
APC Back-UPS XS 1500G says "No battery"
I have a new-ish APC Back-UPS XS 1500G connected via USB. It's giving me a "ups.alarm: No battery installed!" error. I also installed and configured apcupsd to give that a try and it's giving me the same error. I suspect this is a driver problem because while NUT claims the battery isn't plugged in, it's giving me battery runtime/charge info. Both can't be valid
2005 Jan 03
3
UPS - a little OT
Hi all. Can someone recommend a good UPS for using with an * machine that provides some linux tested software to do managed shutdown in case of power loss? Thanks. Shoval Tomer, IT Manager, SofTov Advanced Systems, Ltd. Office: +972-3-9230686 ext. 179 Fax: +972-3-9216642 Mobile: +972-54-8000200
2017 May 12
0
APC Back-UPS XS 1500G says "No battery"
...700 > HOSTNAME : myhost > VERSION : 3.14.14 (31 May 2016) debian > UPSNAME : myups > CABLE : USB Cable > DRIVER : USB UPS Driver > UPSMODE : Stand Alone > STARTTIME: 2017-05-08 23:32:58 -0700 > MODEL : Back-UPS XS 1500G > STATUS : ONLINE NOBATT > LINEV : 120.0 Volts > LOADPCT : 11.0 Percent > BCHARGE : 100.0 Percent > TIMELEFT : 55.8 Minutes > MBATTCHG : 15 Percent > MINTIMEL : 3 Minutes > MAXTIME : 0 Seconds > SENSE : Medium > LOTRANS : 88.0 Volts > HITRANS : 139.0 Volts > ALARMDEL : No alarm &...
2010 Aug 02
3
OT -- apcupsd messages
...56:47 CDT 2010 HOSTNAME : madeleine.localdomain RELEASE : 3.14.3 VERSION : 3.14.3 (20 January 2008) redhat UPSNAME : Clyde CABLE : USB Cable MODEL : Back-UPS XS 1300 LCD UPSMODE : Stand Alone STARTTIME: Sun Aug 01 23:22:04 CDT 2010 STATUS : ONLINE LINEV : 121.0 Volts LOADPCT : 17.0 Percent Load Capacity BCHARGE : 100.0 Percent TIMELEFT : 36.1 Minutes MBATTCHG : 25 Percent MINTIMEL : 10 Minutes MAXTIME : 500 Seconds SENSE : Medium LOTRANS : 088.0 Volts HITRANS : 136.0 Volts ALARMDEL : Always...
2008 Dec 12
1
APC Backups-Pro 650 - Any way to use apcsmart?
...: 001,049,1178 DATE : Fri Dec 12 12:28:11 CST 2008 HOSTNAME : nemesis RELEASE : 3.14.4 VERSION : 3.14.4 (18 May 2008) suse UPSNAME : NEM_0650 CABLE : APC Cable 940-0095A MODEL : BACK-UPS PRO 650 UPSMODE : Stand Alone STARTTIME: Fri Dec 12 12:27:56 CST 2008 STATUS : ONLINE LOWBATT LINEV : 120.9 Volts LOADPCT : 26.0 Percent Load Capacity BCHARGE : 100.0 Percent TIMELEFT : 3.0 Minutes MBATTCHG : 5 Percent MINTIMEL : 3 Minutes MAXTIME : 0 Seconds MAXLINEV : 121.6 Volts MINLINEV : 120.9 Volts OUTPUTV : 120.9 Volts SENSE : High DWAKE : 060 Seconds DSHUTD : 020 Seconds...