Displaying 6 results from an estimated 6 matches for "leg2".
Did you mean:
leg
2005 May 21
1
Uncommon callback
...r rejects, it just place into state
CALL PROGRESS (?) [maybe gives back alerting tone? probably not]
3.#1 notifies that there is a call to number B from number A to system
asterisk2 (#2) - through non-voip protocol [xml-rpc, anything else,
doesn't matter here]
4.#2 dials number B through PSTN - leg2
5.#2 dials #1 (on number #1 sent in notification) through SIP - leg3
6.#2 interconnects leg2 and leg3 without ISDN CONNECT
7.#1 interconnects leg1 and leg2 without ISDN CONNECT
8.when B picks up the phone, channels are getting CONNECT message
I know that my explanation can be a bit mess, but I was...
2009 Jan 19
0
How to add SipAddHeader in outgoing call file.
...t;]?20:2)
exten => h,2,DeadAGI(STD/STD-CBLeg1-RadAuth.pl|${SIP_HEADER(Call-ID)})
exten => h,3,Set(CALLERID(number)=${CALLERID(number)})
exten => h,4,System(echo channel:
SIP/${CallBackNo}@${LCR_TERMINATOR_STD} > /tmp/${CALLERID(number)})
exten => h,5,System(echo context: STD-callback-leg2 >> /tmp/${CALLERID(number)})
exten => h,6,System(echo extension: s >> /tmp/${CALLERID(number)})
exten => h,7,System(echo priority: 1 >> /tmp/${CALLERID(number)})
exten => h,8,System(echo callerid: ${outCallerID} >>
/tmp/${CALLERID(number)}) ; Your CallerID goes here...
2009 Jan 16
2
want to add SipAddHeader in call out file
How to add SipAddHeader in outgoing call file.
I am implementing a Callback scenario, in which a user makes a call to
Local Access Number. The system have to callback to the user. During
callback a call file is generated. All I want, is to add
SipAddHeader("pchargingvector","val") in outgoing Invite.
How can I achieve this?
regards,
Asif
2024 Nov 16
1
Interpreting data from 220V input APC UPS
...age=121
input.L1-L2.voltage.maximum=123
input.L1-L2.voltage.minimum=118
output.L1-L2.voltage=119
output.L1.current=6.10
output.L1.current.maximum=13.20
output.L1.current.minimum=5.50
output.L1.power.maximum.percent=63
output.L1.power.minimum.percent=27
output.L1.power.percent=30
# Substitute "Leg2" for "L2-L3" or "L2"
input.L2-L3.voltage=120
input.L2-L3.voltage.maximum=122
input.L2-L3.voltage.minimum=118
output.L2-L3.voltage=119
output.L2.current=2.30
output.L2.current.maximum=6.30
output.L2.current.minimum=0.90
output.L2.power.maximum.percent=30
output.L2.power.mini...
2024 Nov 11
3
Interpreting data from 220V input APC UPS
John Ackermann N8UR via Nut-upsuser
<nut-upsuser at alioth-lists.debian.net> writes:
> I am monitoring via the SNMP driver an APC SmartUPS that has split
> phase (2L + neutral) 240V input and 120/120 volt outputs. The data
> for the voltages is not what I'm expecting, and I am wondering how I
> should interpret it.
Wow, that sounds kind of industrial. Model?
Is the
2009 May 21
1
[PATCH server] Updated look and feel for empty grid views
...?S1ZhZ&!q^4Ns=}yfb at Tb0tznOTuXDdO
zz at cgaN*R>N=yZoT4GSOW$po)!{+AEm=GXpUm*ZgBG(Fz+M3+DR?jetErp%T#lV!uQ
z3RKSFM4X6tAMgmAkBxx_uwGC(M-u`rNL=tVAz*323vtlwgT!-Z!eLvlQ48<^ngCiz
zsAt$}hE at tGHRJJ=-Wwi4X?_2IDBFzBRwYU&<VjAq=;2G~3CUb7_&dLGz;AwbLP!h`
zcRKvy`wD*i&70V{VQ*H`SWobZ+6SBm=LEG2;K2HTZ332n_kj>}3$P~yg`)+|1*`)H
zc<-=Y;Jw7sX2&A7`GnUrQs4xrM8RT2hC`YhwB+REh;Fyb{V>RS!BDue4x=SP3(`Cx
z(+x*b@;85dk57Dl42kE59?1Bm4_ at RATPcTQ%ZY99HiEHi8iKbFKodxmrbeI$I34g-
z;Dg2@@WJB(SUkZCG=f at 6oR3AR69R<7ivZpc1Tj7aiO116MGzpAK-E*SR3LOp6QC{^
zY;A4bHQ9LWCpM>w{<Mg9_ at I#3#PGL&{W...