search for: lebedinsky

Displaying 13 results from an estimated 13 matches for "lebedinsky".

2020 Jan 08
2
unexpected UPS status
On Tue, 7 Jan 2020, Eyal Lebedinsky wrote: > On 2020-01-07 23:01, Roger Price wrote: >> There is no report for variable "ups.delay.start" in your upsc output. >> What does command "upsc <ups> ups.delay.start" report? > > $ upsc eaton ups.delay.start > Init SSL without certificate da...
2020 Aug 19
4
Eaton 5E 1100i USB UPS - failed to claim USB device error
Hi BACKGROUND INFO:I have a new Eaton 5E 1100i USB UPS which their website claims is supported on Linux. They don't provide software for it for Linux, only for Windows.Referring links: https://www.eaton.com/za/en-gb/catalog/backup-power-ups-surge-it-power-distribution/Eaton_5E_UPS.html https://www.eaton.com/za/en-gb/skuPage.5E1100IUSB.specifications.html It was manufactured in May 2020
2020 Jan 07
2
unexpected UPS status
This is part UPS and part nut question. I had a (intentional) power outage. The UPS/nut properly shut the system down when battery was down to 20%. It ran for only 18 minutes rather than the expected 40 (see later). After it charged to 37% I removed power from the UPS. After 4-5 minutes the system shut down. However, when I restored power to the UPS the machine powered up immediately (no delay).
2019 Sep 06
5
"battery is low" logged
I got around to unplugging my UPS and I found it doesn't last nearly as long as estimated. Is the "upsmon[1446]: UPS desktop_ups at localhost battery is low" logged when "battery.runtime:" = "battery.runtime.low: 120"? Does any make better batteries that don't go down faster when they get old? battery.charge: 100 battery.charge.low: 10
2019 Sep 07
0
"battery is low" logged
..."battery.charge" going below "battery.charge.low"). There are also ways for NUT drivers (see "ignorelb") to make that decision in the driver code rather than looking at the UPS status bit, though generally APC seems to get this right. On Sep 6, 2019, at 7:02 PM, Eyal Lebedinsky wrote: > No UPS that I owned could tell that the batteries are bad, I find this when the UPS power is > disconnected and the UPS shuts down soon (often in seconds). APC, Tripp-Lite, and MGE/Eaton typically do periodic tests that can detect this. Sometimes it isn't on the entry-level mode...
2020 Jan 07
0
unexpected UPS status
On Tue, 7 Jan 2020, Eyal Lebedinsky wrote: > I had a (intentional) power outage. The UPS/nut properly shut the system down > when battery was down to 20%. > It ran for only 18 minutes rather than the expected 40 (see later). > After it charged to 37% I removed power from the UPS. After 4-5 minutes the > system shut...
2020 Jan 08
0
unexpected UPS status
On Wednesday 08 January 2020 06:44:03 Roger Price wrote: > On Tue, 7 Jan 2020, Eyal Lebedinsky wrote: > > On 2020-01-07 23:01, Roger Price wrote: > >> There is no report for variable "ups.delay.start" in your upsc > >> output. What does command "upsc <ups> ups.delay.start" report? > > > > $ upsc eaton ups.delay.start > > Ini...
2020 Aug 19
0
Eaton 5E 1100i USB UPS - failed to claim USB device error
...hought that it is not needed anymore... I manually enabled the quirk with a kernel boot option usbhid.quirks=0x0463:0xffff:0x08 Append this to GRUB_CMDLINE_LINUX_DEFAULT in /boot/grub2/grub.cfg I do not have a record of the source of this advice, I found it searching the 'net. HTH -- Eyal Lebedinsky (eyal at eyal.emu.id.au)
2023 Jan 28
1
nut does not start after reboot
...and I now get readings. >>> interestingly, I later see 2023-01-28T10:12:46+1100 usbhid-ups[26758]: nut_libusb_get_string: Pipe error >>> this message is not seen in /var/log/messages... >>> but I still get readings. >>> maybe an intermittent error? -- Eyal Lebedinsky (eyal at eyal.emu.id.au)
2019 Jul 19
1
USB UPS problem
Maybe a kernel USB issue, but people on this list may have encountered this issue. I am testing a new UPS (EATON 5E 1500iUSB) and am having a problem with the USB connection failing. My old UPS (EATON Ellipse MAX 1500) works just fine with the latest f30. Both devices identify as ID 0463:ffff MGE UPS Systems UPS To narrow the focus I booted recent live CDs on a PC that has no other USB devices
2019 Aug 06
4
Monitor UPS Brand SMS
Hi Users NUT, I want monitor a UPS of brand SMS (Sinus Double 8 KVA) using a raspberry-pi. In compatibility list, is listed to use the blazer_ser driver. I use a USB adapter to RS-232 conected in to the No-Breake. Follow the comands e confs. root at rasp:/home/pi# lsusb *Bus 001 Device 004: ID 067b:2303 Prolific Technology, Inc. PL2303 Serial Port* Bus 001 Device 003: ID 0424:ec00 Standard
2019 Aug 06
0
Monitor UPS Brand SMS
On 06/08/2019 23.14, Mario Michielin Neto wrote: > Hi Users NUT, > > I want monitor a UPS of brand SMS (Sinus Double 8 KVA) using a raspberry-pi. In compatibility list, is listed to use the blazer_ser driver. I use a USB adapter to RS-232 conected in to the No-Breake. Follow the comands e confs. > > root at rasp:/home/pi# lsusb > *Bus 001 Device 004: ID 067b:2303 Prolific
2019 Sep 06
0
"battery is low" logged
On 07/09/2019 08.28, James wrote: > I got around to unplugging my UPS and I found it doesn't last nearly as long as estimated. > > Is the "upsmon[1446]: UPS desktop_ups at localhost battery is low" logged when "battery.runtime:" = "battery.runtime.low: 120"? > > Does any make better batteries that don't go down faster when they get old? In my