search for: kva

Displaying 20 results from an estimated 72 matches for "kva".

2019 Jun 25
1
EROR util/util_http_select_best Input string does not parse as KVA. Selecting first option.
...rything seems to be working fine, so the error doesn't seem to be causing any disruptions on its own, but it is preventing me from troubleshooting other issues. root at radio:/var/log/icecast2# tail error.log [2019-06-24 22:31:21] EROR util/util_http_select_best Input string does not parse as KVA. Selecting first option. [2019-06-24 22:31:22] EROR util/util_http_select_best Input string does not parse as KVA. Selecting first option. [2019-06-24 22:31:22] EROR util/util_http_select_best Input string does not parse as KVA. Selecting first option. [2019-06-24 22:31:22] EROR util/util_http_s...
2019 Aug 06
4
Monitor UPS Brand SMS
Hi Users NUT, I want monitor a UPS of brand SMS (Sinus Double 8 KVA) using a raspberry-pi. In compatibility list, is listed to use the blazer_ser driver. I use a USB adapter to RS-232 conected in to the No-Breake. Follow the comands e confs. root at rasp:/home/pi# lsusb *Bus 001 Device 004: ID 067b:2303 Prolific Technology, Inc. PL2303 Serial Port* Bus 001 Device...
2014 Nov 23
0
[HCL] NHS Expert C Online 6000 supported by gamatronic
On Nov 22, 2014, at 5:16 AM, Thiago Wiezbicki <thiagowzb at gmail.com> wrote: > Below , it's a second upsc command using our UPS on battery and with device ID, battery time, battery low time that UPS calcs correctly. Let me remember now, We have the same UPS in 6, 8, 10 and 12 kVA version, and it's names are : Expert C Online 6000 , 8000 , 10000 and 12000 ( or Expert G III how You can see in upsc output). respectively. > I added the 6, 8 and 10 kVA versions to the HCL, but the 12 kVA seems to be part of the Expert S Online series: http://www.nhs.com.br/produto...
2023 Jul 20
1
[PATCH drm-misc-next v8 02/12] drm: debugfs: provide infrastructure to dump a DRM GPU VA space
...DRM GPU VA space drivers should call this function from their + * &drm_info_list's show callback. + * + * Returns: 0 on success, -ENODEV if the &mgr is not initialized + */ +int drm_debugfs_gpuva_info(struct seq_file *m, + struct drm_gpuva_manager *mgr) +{ + struct drm_gpuva *va, *kva = &mgr->kernel_alloc_node; + + if (!mgr->name) + return -ENODEV; + + seq_printf(m, "DRM GPU VA space (%s) [0x%016llx;0x%016llx]\n", + mgr->name, mgr->mm_start, mgr->mm_start + mgr->mm_range); + seq_printf(m, "Kernel reserved node [0x%016llx;0x%016llx]\n&quo...
2014 Nov 22
2
[HCL] NHS Expert C Online 6000 supported by gamatronic
...atus on the UPS? A: Yes, the shutdown occours when ups.status it's equal OB LB Below , it's a second upsc command using our UPS on battery and with device ID, battery time, battery low time that UPS calcs correctly. Let me remember now, We have the same UPS in 6, 8, 10 and 12 kVA version, and it's names are : Expert C Online 6000 , 8000 , 10000 <callto:6000%20,%208000%20,%2010000> and 12000 ( or Expert G III how You can see in upsc output). respectively. battery.charge: 087 battery.current: 0.0 battery.date: 11172014 battery.runtime: 00687 battery.runtime....
2006 Mar 20
1
FreeBSD box dropping packets
Dear All, I have a FreeBSD box running 5.4-RELEASE-p8. Two interfaces: fxp0 - internet, SKA4 internal interface fxp0: <Intel 82559 Pro/100 Ethernet> bge0 - internal with 30 vlans on it, old bge Gigabit 64/32 PCI-2.1 adapter. bge0: <Altima AC1002 Gigabit Ethernet, ASIC rev. 0x105> Firewall is pf with about 5000 rules. A week ago it was working just properly, but after adding more RAM
2019 Oct 11
0
NUT-DRIVER cant start [Emerson Liebert APM 150 kVA]
...4-5cd * Ups.conf [WL_UPS_L4-06] driver = snmp-ups port = 10.42.190.164 desc = "Emerson_Network_Power" mibs = ietf snmp_version = v2c community = *** System Name APM150 Location Testbed 54/009 Description Emerson Liebert APM 150 kVA Contact *** Manufacturer Emerson Network Power Agent Model IntelliSlot Web Card Agent App Firmware Version 5.180.1 Agent App Firmware Label IS-WEBL_HID10_5.180.1_066038 Agent Boot Firmware Version 5.180.0 Agent Boot Firmware Label IS-WEBL_HID10_5.180.0_058784 Agent Hardware ID 10 Agent Serial Numbe...
2006 May 09
1
SNMP-UPS with Sicon Masterys MC
Hello, I have in production one big ups of 30 kVA (MAS-MC 330). I bought recently one Netvision SNMP card and NUT is working with snmp-ups driver: battery.charge: 100.0 battery.runtime: -60.0 battery.voltage: 483.8 driver.name: snmp-ups driver.parameter.mibs: netvision driver.parameter.port: xxx.xxx.xxx.xxx driver.version: 2.0.2 driver.version.in...
2018 Dec 24
2
Freenas configuration Legrand Daker DK1kVA
Hi all, I have an UPS by Legrand, model Daker DK 1 kVA, i have tried to use "nutdrv_qx" driver with usb but have no success. I will send you all the information you need to try to solve or write the correct driver. Hope to be useful. regards Andrea
2006 Aug 08
4
choosing a UPS (in the United States)
I do a bunch of "kindness of strangers" hosting in my basement and my three kVA apc unit died recently. In looking around, it looked like Belkin was a reasonable low-end replacement for a few machines. Then I read this mailing list after I purchased one and was gifted another. It looks like people don't like Belkin. ;-) So the question is what's a good UPS for...
2008 Nov 03
3
compaq r3000 triggering the fuse when power is reconnected
All, I have a fairly old Compaq R3000h which is overdue for new batteries. Before I go and splash out a few hundred francs, I'd just need a quick sanity check - when I disconnect the power (UPS under load), it cuts out pretty much right away, so the batteries are flat (even though the charge indicator says full). When I reconnect the power, the surge triggers a 16A mains fuse. This sounds
2019 Aug 07
0
Monitor UPS Brand SMS
...I have recently been fuddled due to permission problems of various sorts. Are you sure that the user under which nut is running is able to access the /dev/ttyUSB file? On 8/6/2019 6:14 AM, Mario Michielin Neto wrote: > Hi Users NUT, > > I want monitor a UPS of brand SMS (Sinus Double 8 KVA) using a > raspberry-pi. In compatibility list, is listed to use the blazer_ser > driver. I use a USB adapter to RS-232 conected in to the No-Breake. > Follow the comands e confs. > > root at rasp:/home/pi# lsusb > *Bus 001 Device 004: ID 067b:2303 Prolific Technology, Inc. PL2303...
2019 Aug 06
0
Monitor UPS Brand SMS
On 06/08/2019 23.14, Mario Michielin Neto wrote: > Hi Users NUT, > > I want monitor a UPS of brand SMS (Sinus Double 8 KVA) using a raspberry-pi. In compatibility list, is listed to use the blazer_ser driver. I use a USB adapter to RS-232 conected in to the No-Breake. Follow the comands e confs. > > root at rasp:/home/pi# lsusb > *Bus 001 Device 004: ID 067b:2303 Prolific Technology, Inc. PL2303 Serial Port*...
2012 Apr 27
1
hardware compatibility list
...nical information about ups so much. so i send hardware compatibility list to my friend who worked at ups manufacturer factory. his commet : "ups at the list are, one phase support,not 3 phase. there are 3 phase support ups at market" and "ups in the list are not very big, maximum 6 kva. there are bigger ups at market." are there any limitation about 3 phase support and power of ups? cheers,Ramazan -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20120427/3aee6c6a...
2016 May 29
2
New driver
Hi, First of all I'd like to congratulate everyone engaged in this great project. I've been following this list since late 2014, when I acquired an APC UPS model BZ1200BR. APC bought a Brazilian company named Microsol, which NUT package had drivers for Solis and Rhino models. Since that time, I started developing a new driver for the models below, as a way to support my own device, but
2014 Oct 01
2
Socomec ITYS 3000 + Netvision upsmon output
...6.5 64-bit. NUT installed with yum,. nut-2.6.5-2.el6.x86_64 nut-client-2.6.5-2.el6.x86_64 Why is ups.status empty? Here is upsc output: upsc myups at localhost battery.charge: 97.00 battery.runtime: -60.00 battery.voltage: -0.10 device.mfr: Net Vision v6.01 (SN 0101414290) device.model: ITYS 3 kVA device.serial: 3I14450043 device.type: ups driver.name: snmp-ups driver.parameter.mibs: netvision driver.parameter.pollfreq: 15 driver.parameter.pollinterval: 2 driver.parameter.port: 192.168.20.249 driver.parameter.snmp_version: v1 driver.version: 2.6.5 driver.version.data: netvision MIB 0.3 drive...
2008 Jul 13
1
dvd dma problems
I have a couple of DVD drives (one drive, one burner) that used to play DVDs quite fine from 5.3 to somewhere in the 6.x branch. Nowadays I have to send them to PIO4 to play DVDs, because they'll just throw DMA not aligned errors around in UDMA33 or WDMA2 mode. Should someone be interested in this I'm willing to supply all necessary information, such as the exact drives, firmware
2008 Nov 24
1
RELENG_7 panic under load: vm_page_unwire: invalid wire count: 0
...0xffffffffea28fc80) at /usr/src/sys/kern/kern_fork.c:804 #15 0xffffffff8045b88e in fork_trampoline () at /usr/src/sys/amd64/amd64/exception.S:455 #16 0x0000000000000000 in ?? () #17 0x0000000000000000 in ?? () #18 0x0000000000000001 in ?? () in /boot/loader.conf I have: vm.kmem_size=1536M # 2 Mb KVA/kmem net.inet.tcp.tcbhashsize=131072 # 64M KVA kern.maxbcache=64M # 4M KVA kern.ipc.maxpipekva=4M # net.inet.tcp.syncache.hashsize=1024 net.inet.tcp.syncache.bucketlimit=100 in /etc/sysctl.conf # 576 Mb KVA/kmem kern.ipc.nmbclusters=262144 kern.ipc.nmbjumbop=65536 kern.ipc.maxsockets=307200 kern...
2008 Jul 04
1
Powerware UPS slots ports and protocols information
...and other info source to see if there's a gap? thanks, Arnaud ________________________________________________________________________ Old info from ca. 2002, but still mostly valid except that some 5125s got a USB port built in, as well as 9125 5 and 6 Kva. Newer ones are on a web server that is currently down. Please note when looking at connectivity option table: - Only one port can be used at a time with 5115RM - RS232 and USB cannot be used simultaneously on 9120 - SNMP option will be replaced by SNMP/WEB option. Since then we?ve...
2012 Apr 16
2
Snmp-ups/netvision driver for Socomec UPS
...Network UPS Tools - Generic SNMP UPS driver 0.50 (2.6.1) 0.000000 debug level is '1' 0.000260 SNMP UPS driver : entering upsdrv_initups() 0.027868 load_mib2nut: trying netvision mib 0.029798 load_mib2nut: using netvision mib 0.031731 Detected NETYS 3 kVA on host 192.168.0.227 (mib: netvision 0.1) 0.031751 SNMP UPS driver : entering upsdrv_initinfo() 0.031785 getting data: ups.mfr (.1.3.6.1.4.1.4555.1.1.1.1.1.3.0) 0.033823 entering su_setinfo(ups.mfr) 0.033836 getting data: ups.model (.1.3.6.1.4.1.4555.1.1.1.1.1.1.0)...