search for: klesperance

Displaying 11 results from an estimated 11 matches for "klesperance".

Did you mean: lesperance
2016 May 25
2
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
[merging] The HBA the drives are attached to has no configuration that I?m aware of. We would have had to accidentally change 23 of them ? Thanks, Kelly On 2016-05-25, 1:25 PM, "Kelly Lesperance" <klesperance at blackberry.com> wrote: >They are: > >[root at r1k1 ~] # hdparm -I /dev/sda > >/dev/sda: > >ATA device, with non-removable media > Model Number: MB4000GCWDC > Serial Number: S1Z06RW9 > Firmware Revision: HPGD...
2016 May 25
0
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
Hdparm didn?t get far: [root at r1k1 ~] # hdparm -tT /dev/sda /dev/sda: Timing cached reads: Alarm clock [root at r1k1 ~] # On 2016-05-25, 2:44 PM, "Kelly Lesperance" <klesperance at blackberry.com> wrote: >The HBA is an HP H220. > >We haven?t really benchmarked individual drives ? all 12 drives are utilized in one RAID-10 array, I?m unsure how we would test individual drives without breaking the array. > >Trying ?hdparm -tT /dev/sda? now ? it?s been run...
2016 May 25
6
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
...te: >> [merging] >> >> The HBA the drives are attached to has no configuration that I?m aware of. We would have had to accidentally change 23 of them ? >> >> Thanks, >> >> Kelly >> >> On 2016-05-25, 1:25 PM, "Kelly Lesperance" <klesperance at blackberry.com> wrote: >> >>> They are: >>> >>> [root at r1k1 ~] # hdparm -I /dev/sda >>> >>> /dev/sda: >>> >>> ATA device, with non-removable media >>> Model Number: MB4000GCWDC...
2016 May 25
0
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
....05.2016 19:26, Kelly Lesperance wrote: > [merging] > > The HBA the drives are attached to has no configuration that I?m aware of. We would have had to accidentally change 23 of them ? > > Thanks, > > Kelly > > On 2016-05-25, 1:25 PM, "Kelly Lesperance" <klesperance at blackberry.com> wrote: > >> They are: >> >> [root at r1k1 ~] # hdparm -I /dev/sda >> >> /dev/sda: >> >> ATA device, with non-removable media >> Model Number: MB4000GCWDC >> Serial Number: S1Z06...
2016 May 25
3
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
Kelly Lesperance wrote: > LSI/Avago?s web pages don?t have any downloads for the SAS2308, so I think > I?m out of luck wrt MegaRAID. > > Bounced the node, confirmed MPT Firmware 15.10.09.00-IT. > HP Driver is v 15.10.04.00. > > Both are the latest from HP. > > Unsure why, but the module itself reports version 20.100.00.00: > > [root at r1k1 sys] # cat
2016 Jun 01
0
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
...-back cache is NOT enabled for the drives on the hosts we haven't upgraded yet, but the speeds are similar (I kicked off a raid check on one of our CentOS 6 hosts as well, the window seems to be 150000 - 200000K/Sec on that host). Kelly On 2016-05-27, 9:21 AM, "Kelly Lesperance" <klesperance at blackberry.com> wrote: >All of our Kafka clusters are fairly write-heavy. The cluster in question is our second-heaviest ? we haven?t yet upgraded the heaviest, due to the issues we?ve been experiencing in this one. > >Here is an iostat example from a host within the same cluster,...
2016 May 27
2
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
All of our Kafka clusters are fairly write-heavy. The cluster in question is our second-heaviest ? we haven?t yet upgraded the heaviest, due to the issues we?ve been experiencing in this one. Here is an iostat example from a host within the same cluster, but without the RAID check running: [root at r2k1 ~] # iostat -xdmc 1 10 Linux 3.10.0-327.13.1.el7.x86_64 (r2k1) 05/27/16 _x86_64_ (32 CPU)
2016 May 25
6
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
I?ve posted this on the forums at https://www.centos.org/forums/viewtopic.php?f=47&t=57926&p=244614#p244614 - posting to the list in the hopes of getting more eyeballs on it. We have a cluster of 23 HP DL380p Gen8 hosts running Kafka. Basic specs: 2x E5-2650 128 GB RAM 12 x 4 TB 7200 RPM SATA drives connected to an HP H220 HBA Dual port 10 GB NIC The drives are configured as one large
2016 May 25
0
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
LSI/Avago?s web pages don?t have any downloads for the SAS2308, so I think I?m out of luck wrt MegaRAID. Bounced the node, confirmed MPT Firmware 15.10.09.00-IT. HP Driver is v 15.10.04.00. Both are the latest from HP. Unsure why, but the module itself reports version 20.100.00.00: [root at r1k1 sys] # cat module/mpt2sas/version 20.100.00.00 On 2016-05-25, 3:20 PM, "centos-bounces at
2016 May 25
0
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
Already done ? they?re not being very helpful, as we don?t have a support contract, just standard warranty. On 2016-05-25, 4:27 PM, "centos-bounces at centos.org on behalf of m.roth at 5-cent.us" <centos-bounces at centos.org on behalf of m.roth at 5-cent.us> wrote: >Kelly Lesperance wrote: >> LSI/Avago?s web pages don?t have any downloads for the SAS2308, so I think
2016 Jun 01
0
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
Software RAID 10. Servers are HP DL380 Gen 8s, with 12x4 TB 7200 RPM drives. On 2016-06-01, 3:52 PM, "centos-bounces at centos.org on behalf of m.roth at 5-cent.us" <centos-bounces at centos.org on behalf of m.roth at 5-cent.us> wrote: >Kelly Lesperance wrote: >> I did some additional testing - I stopped Kafka on the host, and kicked >> off a disk check, and it