search for: irp_mj_writ

Displaying 6 results from an estimated 6 matches for "irp_mj_writ".

Did you mean: irp_mj_write
2014 Jan 14
2
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
...what were set unable to detect an APC Smart protocol UPS on port com1 check the cabling, port name or model name and try again ups.conf: [ups] driver=apcsmart port=com1 cable=940-0095B desc="test" Sysinternals Portmon captures the following activity on com1: 0.00009862 apcsmart.exe IRP_MJ_WRITE Serial0 SUCCESS Length 1: 59 Y 0.00001090 apcsmart.exe IRP_MJ_READ Serial0 SUCCESS Length 1: 53 S 0.00000950 apcsmart.exe IRP_MJ_READ Serial0 SUCCESS Length 3: 4D 0D 0A M [CR] [LF] 1.48775808 apcsmart.exe IRP_MJ_READ Serial0 TIMEOUT...
2013 Jan 30
3
bug report: apcsmart (WIN) 940-0024C connect fail, problem with command 'E'
...OCTL_SERIAL_GET_HANDFLOW Serial0 56 0.00000363 SUCCESS 57 0.00000000 apcsmart.exe IOCTL_SERIAL_PURGE Serial0 Purge: TXABORT TXCLEAR 57 0.00000810 SUCCESS 58 0.00000000 apcsmart.exe IOCTL_SERIAL_PURGE Serial0 Purge: RXABORT RXCLEAR 58 0.00000866 SUCCESS 60 0.00000000 apcsmart.exe IRP_MJ_WRITE Serial0 Length 1: 59 60 0.00003995 SUCCESS 61 0.00000000 apcsmart.exe IOCTL_SERIAL_GET_TIMEOUTS Serial0 61 0.00000559 SUCCESS 62 0.00000000 apcsmart.exe IOCTL_SERIAL_SET_TIMEOUTS Serial0 RI:-1 RM:0 RC:1500 WM:0 WC:0 62 0.00000447 SUCCESS 63 0.00000000 apcsmart.exe IOCTL_SERIAL_...
2014 Jan 14
0
Unable to detect an APC Smart protocol UPS. Windows. APC Smart protocol driver 3.04 (2.6.5-3723:3731M)
...well, so if it's not possible - you can use the previous version easily. > ups.conf: > [ups] > driver=apcsmart > port=com1 > cable=940-0095B > desc="test" > > Sysinternals Portmon captures the following activity on com1: > > 0.00009862 apcsmart.exe IRP_MJ_WRITE Serial0 SUCCESS Length 1: 59 Y > 0.00001090 apcsmart.exe IRP_MJ_READ Serial0 SUCCESS Length 1: 53 S > 0.00000950 apcsmart.exe IRP_MJ_READ Serial0 SUCCESS Length 3: 4D 0D 0A M [CR] [LF] > 1.48775808 apcsmart.exe IRP_MJ_READ S...
2011 Apr 23
3
Richcomm Serial driver
Hi, I'm trying to configure my ups with nut which is a locally made one. It uses a rs232 port to talk to the computer and comes with a software called "Powermanager Lite" which is provided by Richcomm and supports Windows, Linux and UNIX. According to the manual it uses the Richcomm circuitry to talk to the computer and uses a drycontact protocol. Unfortunately I couldn't
2016 Oct 14
0
Wine release 1.9.21
...NULL. ntoskrnl.exe: Fix parameters of IoBuildSynchronousFsdRequest in dispatch_flush. ntoskrnl.exe: Use completion routine to transfer result of IRP back to server. user32/tests: Fix test failures on 64-bit testbot VMs. ntoskrnl.exe: Don't transfer back input buffer for IRP_MJ_WRITE requests. ntoskrnl.exe: Add support for async close processing. ntoskrnl.exe: Fix management of input/output buffers in dispatch handlers. ntoskrnl.exe: Do not abuse UserEvent to store event handle. winebus.sys: Add a strdupAtoW implementation. Stefan Dösinger (6): d...
2015 Oct 16
0
Wine release 1.7.53
...tainers: Add uniscribe maintainer section. hidclass.sys: Help make the logic around feature input flags more apparent. hidclass.sys: Make sure we pass in the index not a pointer to the index. hidclass.sys: Add a processing thread for HID devices. hidclass.sys: Stub to handle IRP_MJ_WRITE on HID devices. hidclass.sys: Implement sending IRP_MJ_PNP to the minidriver. hidclass.sys: Implement sending IRP_MJ_POWER to the minidriver. hidclass.sys: Implement IOCTL_GET(SET)_NUM_DEVICE_INPUT_BUFFERS. Austin English (6): kernel32: Add a stub for GetCurrentProcessorNu...