search for: interruptonly

Displaying 5 results from an estimated 5 matches for "interruptonly".

2018 Aug 22
2
TrippLite SMX1500LCDT FreeBSD 11.2 trouble
Understood about unplugging USB - others with the 3016 devices have proposed various methods with USB hubs that have per-port power switching, etc. to simulate unplugging. I am not a fan of the concept, but I recognize that others have made more significant investments than the single UPS that I bought. After you get access to the UPS, what if you try running the driver with
2018 Aug 22
0
TrippLite SMX1500LCDT FreeBSD 11.2 trouble
With interruptonly the driver output goes into a loop (is it an expected behavior?) After I interrupt the loop and launch the driver again, it would return "No matching HID device found" until I unplug / re-plug USB cable. Gzipped output is attached. > On Wed, Aug 22, 2018 at 3:49 PM Charles Lepple &lt...
2016 Oct 12
4
Data Stale at random intervals
...on Raspbian with the same issue. Seems I may be missing something in the configuration, but haven't been able to find anything yet. Which kernel version is your release of Raspbian running? The logs seem to indicate that your UPS frequently sends status via interrupt reports. Does the "interruptonly" option help? If so, you can also try again without interruptonly (since that option might prevent certain variables from updating), but with increased timeouts for pollfreq and pollinterval. Partially due to pressure from Debian, there is a libusb-1.0 branch of NUT now. That seemed to work b...
2016 Oct 12
2
Data Stale at random intervals
Have done more Googling and searching around the system. Found that /lib/udev/rules.d/52-nut-usbups.rules has been changed to 62 by others and also in Sid (2.7.4) so gave that a shot. Will post back with results. ________________________________ From: Daniel Shields <grungelizard9 at hotmail.com> Sent: Monday, October 10, 2016 10:51 PM To: nut-upsuser at lists. alioth. debian. org
2016 Nov 22
1
Powerwalker VI 2200VA LCD
I dont think the logs ends to early. The UPS had been offline for 1 day at least before i stopped the process. Could the issue be that NUT driver does not see the USB device disconnect? -------- Original Message -------- Subject: Re: [Nut-upsuser] Powerwalker VI 2200VA LCD Local Time: 11 November 2016 1:12 AM UTC Time: 11 November 2016 00:12 From: hyouko at gmail.com To: Lars de Bruin