Displaying 2 results from an estimated 2 matches for "input_phases".
2014 Feb 27
2
snmp-ups sends status "OL OB" on HP R3000 UPS with AF465A management card
...3.3.1.0)
0.170394 su_ups_get: input.frequency .1.3.6.1.4.1.232.165.3.3.1.0
0.174496 entering su_setinfo(input.frequency)
0.174547 => value: 50.00
0.174571 Check output_phases
0.174621 Check output_phases
0.174643 Check output_phases
0.174687 Check input_phases
0.174731 input_phases is not 3
0.174780 Check input_phases
0.174823 input_phases is not 3
0.174856 Check input_phases
0.174882 input_phases is not 3
0.174909 Check output_phases
0.174935 Check output_phases
0.174965 Check input_phases
0.174...
2014 Aug 30
1
snmp-ups and constants in snmp_info_t snmp2nut tables
...ing to add support for my unit, which is a 3-phase UPS.
I can't find any oids that holds that data so I can determine that, so I
think I need to add it statically.
I've tried the following, (nut-2.7.2)
...
{ "input.phases", 0, 1.0, NULL, "3", SU_FLAG_SETINT, NULL, &input_phases },
...
That ends up as (snmp-ups -a foo -DDDD)
...
0.177686 getting data: input.phases ((null))
0.177690 su_ups_get: input.phases (null)
...
How do I add a constant value to {input|output|bypass}_phases ?
//Erik