2008 Feb 16
3
Unitek UPS 1250xD - megatec_usb driver
.../pipermail/nut-upsuser/2007-December/003573.html which was discussing the issue with the megatec_usb driver detecting the ups.status as OFF instead of OL or OB. With the patch now applied I get the following: battery.charge: 67.2 battery.voltage: 25.20 battery.voltage.nominal: 23.5 driver.flag.ignoreoff: enabled driver.name: megatec_usb driver.parameter.bus: 003 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.parameter.productid: 0000 driver.parameter.vendorid: 0001 driver.version: 2.2.1- driver.version.internal: 1.5.9 input.frequency: 50.0 input.voltage: 229.0 input.voltage.fa...
2008 Feb 16
3
Unitek UPS 1250xD - megatec_usb driver
.../pipermail/nut-upsuser/2007-December/003573.html which was discussing the issue with the megatec_usb driver detecting the ups.status as OFF instead of OL or OB. With the patch now applied I get the following: battery.charge: 67.2 battery.voltage: 25.20 battery.voltage.nominal: 23.5 driver.flag.ignoreoff: enabled driver.name: megatec_usb driver.parameter.bus: 003 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.parameter.productid: 0000 driver.parameter.vendorid: 0001 driver.version: 2.2.1- driver.version.internal: 1.5.9 input.frequency: 50.0 input.voltage: 229.0 input.voltage.fa...
2011 Jan 14
6
Plexus UPS on a QNAP NAS
...ation not permitted Driver failed to start (exit status=1) My ups.conf looks like this [qnapups] driver = usbhid-ups port = auto mfr = "Plexus" model = "Plexus 500VA UPS" desc = "Workstation" pollinterval=1 ignoreoff lsusb shows before the UPS is plugged in [~] # lsusb Bus 001 Device 003: ID 04a9:10b0 Canon, Inc. Bus 001 Device 002: ID 05e3:0608 Genesys Logic, Inc. Bus 001 Device 001: ID 1d6b:0002 And after [~] # lsusb Bus 001 Device 004: ID 0001:0000 Fry's Electronics Bus 001 Device 003: ID 04a...
2006 Apr 08
4
New UPS protocol choice - Dynamix
Gidday all - I'm a new user to nut. I've got some cheap powerpal UPSs working fairly well. However I also have a new Dynamix UPS-1700D and an old Powercom KIN-1700 something unit that I cannot make work right. The best method I've found is "trial and error" which sounds a bit last-resort. Is there any better way to find out what protocol is used? -- Criggie
2008 Feb 12
1
SMS and Megatec protocol Diffs
..., thanks for the patch. But I have a few comments: Are you saying the UPS raises the "OFF" flag when a timed shutdown command is sent to it, before actually shutting down? If so, that is a violation of the megatec protocol. The megatec version in the development trunk has an option "ignoreoff" to accomodate UPSes that exibit this behavior. > Know working SMS Models : > > SINUS Single : Only versions > Manager III : Only serial versions I'll add this to the compatibility list. > /* Known battery types must be in ascending order by "nominal" first, a...
2015 Mar 17
4
(Tuncmatic returns FSD all the time)
...d issue (as root): blazer_usb -a ups -DDD >> /path/to/my/precious/log 2>&1 (keep it running till the test is over - this is the log we are after) 6) Turn the UPS off 6.1) Turn the UPS on [Me too, I'm inclined to see it as a bogus value (in the old megatec driver there was the 'ignoreoff' option that dealed with it - although the value was mapped as an on/off status rather than the actual 'shutdown active'), but the 7th bit of the status byte should change only while the UPS is shutting down and then be back at its original value: if you turned off the UPS with a button...
2015 Mar 16
2
(no subject)
I've done all the steps. However FSD indication did NOT disappear. So it seems UPS always send the FSD flag. -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsdev/attachments/20150316/fd7ccc7a/attachment.html>
2015 Mar 16
0
(Tuncmatic returns FSD all the time)
On Mar 16, 2015, at 12:26 PM, cinowell <cinowell at gmail.com> wrote: > I've done all the steps. However FSD indication did NOT disappear. So it seems UPS always send the FSD flag. I know this sounds kind of ridiculous, but you could use a hex editor to change 'FSD' to 'OFF' in blazer_usb (it only seems to occur once), which would restore the behavior of
2015 Mar 20
0
(Tuncmatic returns FSD all the time)
...-a ups -DDD >> /path/to/my/precious/log 2>&1 > (keep it running till the test is over - this is the log we are after) > 6) Turn the UPS off > 6.1) Turn the UPS on > > [Me too, I'm inclined to see it as a bogus value (in the old megatec > driver there was the 'ignoreoff' option that dealed with it - although > the value was mapped as an on/off status rather than the actual > 'shutdown active'), but the 7th bit of the status byte should change > only while the UPS is shutting down and then be back at its original > value: if you turned off t...
2008 May 24
1
More info about Unitek UPS not working with Megatec driver
Hi again, I tested several times using the Megatec driver from nut 2.2.2 to no avail, as it definitely never "sees" the UPS. Always getting : # drivers/megatec -DDD -a Alpha Network UPS Tools 2.2.2 - Megatec protocol driver 1.5.14 [megatec] Carlos Rodrigues (c) 2003-2008 debug level is '3' Starting UPS detection process... Asking for UPS status [Q1]... Q1 => FAILED
2010 Mar 16
1
NUT megatec driver tunning
...iled (minimum failures: 2). > Cancelling any pending shutdown or battery test. > Asking for UPS information [I]... > I => OK [#Sinapse ? ? ? ? MS II ? ? ?MS3006AG ?] > I VALUES => [Sinapse MS II MS3006AG] > Megatec protocol UPS detected [Sinapse MS II MS3006AG]. > Parameter [ignoreoff]: [false] > Asking for UPS power ratings [F]... > F => OK [#230.0 026 240.0 50.0] > F VALUES => [230.0 26.0 240.0 50.0] > Unsupported battery voltage (240.0V). > This UPS has an unsupported combination of battery voltage/number of > batteries. > Parameter [battvoltmult]:...
2008 Apr 11
1
[Bug 215389] [NEW] No battery charge percentage on belkin usb avr
...ing any pending shutdown or battery test. > Asking for UPS information [I]... > get_data_agiler: raw dump: (0 bytes) => > get_data_agiler: raw dump: (0 bytes) => > I => FAILED [short read] > I detail: (0 bytes) => > Megatec protocol UPS detected. > Parameter [ignoreoff]: [false] > Asking for UPS power ratings [F]... > get_data_agiler: raw dump: (0 bytes) => > get_data_agiler: raw dump: (24 bytes) => 23 32 33 30 2e 30 20 30 30 32 20 > 31 32 2e 30 30 20 35 30 2e 30 0d 30 30 > F => OK [#230.0 002 12.00 50.0] > 12.0V battery, interva...
2008 Sep 12
4
Megatec_USB on OpenBSD 4.3 - no input interrupt endpoint
...failures: 2). Cancelling any pending shutdown or battery test. set_data_krauler: index [0b] set_data_krauler: retry [UPS No Ack] Asking for UPS information [I]... set_data_krauler: index [0c] I => OK [# VT120725 ] Megatec protocol UPS detected [ VT120725]. Parameter [ignoreoff]: [false] Asking for UPS power ratings [F]... set_data_krauler: index [0d] F => OK [#220.0 000 024.0 50.0] 24.0V battery, interval [19.4V, 27.4V]. Done setting up the UPS. Asking for UPS status [Q1]... set_data_krauler: index [03] Q1 => OK [(221.8 140.0 222.0 016 49.9 27.5 30.0 00001001] Calc...
2008 Sep 12
4
Megatec_USB on OpenBSD 4.3 - no input interrupt endpoint
...failures: 2). Cancelling any pending shutdown or battery test. set_data_krauler: index [0b] set_data_krauler: retry [UPS No Ack] Asking for UPS information [I]... set_data_krauler: index [0c] I => OK [# VT120725 ] Megatec protocol UPS detected [ VT120725]. Parameter [ignoreoff]: [false] Asking for UPS power ratings [F]... set_data_krauler: index [0d] F => OK [#220.0 000 024.0 50.0] 24.0V battery, interval [19.4V, 27.4V]. Done setting up the UPS. Asking for UPS status [Q1]... set_data_krauler: index [03] Q1 => OK [(221.8 140.0 222.0 016 49.9 27.5 30.0 00001001] Calc...
2008 Jun 27
2
Megatec and Belkin F6H550-UPS
...60.2 13.6 N/.A 00001001] > 0 out of 5 detection attempts failed (minimum failures: 2). > Cancelling any pending shutdown or battery test. > Asking for UPS information [I]... > I => FAILED [short read] > I detail: (0 bytes) => > Megatec protocol UPS detected. > Parameter [ignoreoff]: [false] > Asking for UPS power ratings [F]... > F => OK [#120.0 005 12.00 60.0] > 12.0V battery, present voltage (8549026304.0V) outside of supported > intervals. > This UPS has an unsupported combination of battery voltage/number of > batteries. > Cannot calculate charge...
2010 Oct 03
1
You lost support of Belkin Universal UPS F6C1100-UNV
...battery test. Asking for UPS information [I]... I => FAILED [short read] I detail: (1 bytes) => 49 send_to_all: SETINFO ups.mfr "unknown" send_to_all: SETINFO ups.model "unknown" Megatec protocol UPS detected. send_to_all: SETINFO ups.serial "unknown" Parameter [ignoreoff]: [false] Asking for UPS power ratings [F]... ok get_data_phoenix: got so far [#120.0 0] get_data_phoenix: (8 bytes) => 23 31 32 30 2e 30 20 30 ok get_data_phoenix: got so far [#120.0 006 24.00] get_data_phoenix: (16 bytes) => 23 31 32 30 2e 30 20 30 30 36 20 32 34 2e 30 30 ok 00]_data_ph...