Displaying 1 result from an estimated 1 matches for "hipath3000".
2005 Sep 19
0
Call dropped 100% of time when incoming IAX routed to outgoing CAPI
...occurs when a call
comes in on an IAX channel and goes out the CAPI interface.
The capi debug in the asterisk console is below as well as the relevent parts
of .conf files from the machines involved.
The scenario is this (extension numbers):
4074 is connected to a Siemens Hipath 3000 PBX.
The Hipath3000 has a cable running to asterisk at address 192.168.1.222
connected to a wcte11xp zaptel card - Single span PRI.
The asterisk at 222 just mentioned (*@222) is on the LAN and it accepts calls
from the Hipath3000 in a certain range and sends the calls to locally
connected SIP extensions. When ext 4...