2017 Jun 04
0
[HCL] Cyber Power Systems CP1500AVRLCDa supported by usbhid-ups
...om the CP1500AVRLCDa HID descriptor:
Collection(Physical)
Report ID(16)
Usage(LowVoltageTransfer)
Logical Minimum(97)
Logical Maximum(103)
Feature(Data,Variable,Absolute)
Usage(LowVoltageTransfer)
Input(Constant,Variable,Absolute)
Usage(HighVoltageTransfer)
Logical Minimum(136)
Logical Maximum(142)
Feature(Data,Variable,Absolute)
Usage(HighVoltageTransfer)
Input(Constant,Variable,Absolute)
Report ID(18)
Usage(Voltage)
Feature(Constant,Variable,Absolute)
Report Size(8)
Lo...
2017 Jun 03
2
[HCL] Cyber Power Systems CP1500AVRLCDa supported by usbhid-ups
On 5/30/2017 10:47 PM, Charles Lepple wrote:
> On May 22, 2017, at 11:13 AM, Mike <the.lists at mgm51.com> wrote:
>>
>> On 5/21/2017 10:39 AM, Charles Lepple wrote:
[snip]
> Even though the CPS sub-driver has been written already, I would like to take a look at the raw "explore" mode output:
>
>
2019 Jan 28
2
Just an interesting data point [CyberPower SNMP/USB]
On 1/27/19 9:49 PM, Charles Lepple wrote:
> You might be lucky with this particular model, but definitely beware of the USB issues I mentioned in another thread:
>
> https://github.com/networkupstools/nut/issues?q=is%3Aissue+is%3Aopen+label%3A%22CyberPower+%28CPS%29%22
>
> The output of upsc is sorted alphabetically by key, so it isn't immediately obvious which values come
2018 Sep 01
0
Adding drivers to NUT?
...Now, just a few questions on the mapping:
1. Are the following items read-only?
And do they change from time to time and need to be polled, or once
retrieved they remain the same (i.e. they are static)?
- input.transfer.low / UPS.Input.LowVoltageTransfer
- input.transfer.high / UPS.Input.HighVoltageTransfer
- input.transfer.low / UPS.PowerConverter.Output.LowVoltageTransfer
- input.transfer.high / UPS.PowerConverter.Output.HighVoltageTransfer
- battery.charge.warning / UPS.PowerSummary.WarningCapacityLimit
- battery.charge.low / UPS.PowerSummary.RemainingCapacityLimit
2. Do the following...
2006 Sep 08
3
newhidups with APC Smart-UPS 1500
Hello,
I'm using the stable amd64 port of Debian Linux. I installed (the
latest) nut-2.0.1-4 and nut-usb packages for utilizing an APC Smart-UPS
1500 USB. I tried "apcupsd" first but "nut" makes an even more
sophisticated impression on me and has more security options.
I had problems with the newhidups driver. It didn't find a device with
matching VendorID. And
2018 Sep 03
0
Adding drivers to NUT?
...gt; 1. Are the following items read-only?
> > And do they change from time to time and need to be polled, or once
> > retrieved they remain the same (i.e. they are static)?
> > - input.transfer.low / UPS.Input.LowVoltageTransfer
> > - input.transfer.high / UPS.Input.HighVoltageTransfer
> > - input.transfer.low / UPS.PowerConverter.Output.LowVoltageTransfer
> > - input.transfer.high / UPS.PowerConverter.Output.HighVoltageTransfer
> > - battery.charge.warning / UPS.PowerSummary.WarningCapacityLimit
> > - battery.charge.low / UPS.PowerSummary.Re...
2006 Sep 22
1
Ablerex 625L USB version
...0.30
(2.1.0)
Path: 00860004.Flow.FlowID, Type: Feature, Value: 0.000000
Path: 00860004.Flow.ConfigVoltage, Type: Feature, Value: 0.000000
Path: 00860004.Flow.ConfigFrequency, Type: Feature, Value: 0.000000
Path: 00860004.Flow.LowVoltageTransfer, Type: Feature, Value: 0.000000
Path: 00860004.Flow.HighVoltageTransfer, Type: Feature, Value: 0.000000
Path: 00860004.Flow.iManufacturer, Type: Feature, Value: 0.000000
Path: 00860004.Flow.iProduct, Type: Feature, Value: 0.000000
Path: 00860004.Flow.iSerialNumber, Type: Feature, Value: 0.000000
Path: 00860004.Flow.FlowID, Type: Feature, Value: 0.000000
Path: 0086000...
2006 Oct 18
2
newhidups with APC Smart-UPS 1500
...: UPS.Output.Frequency, Type: Feature, Value: 50.000004
> > Path: UPS.Output.Voltage, Type: Feature, Value: 231.800003
> > Path: UPS.Output.ConfigVoltage, Type: Input, Value: 230.000000
> > Path: UPS.Output.ConfigVoltage, Type: Feature, Value: 230.000000
> > Path: UPS.Output.HighVoltageTransfer, Type: Input, Value: 253.000000
> > Path: UPS.Output.HighVoltageTransfer, Type: Feature, Value:
> > 253.000000
> > Path: UPS.Output.LowVoltageTransfer, Type: Input, Value: 208.000000
> > Path: UPS.Output.LowVoltageTransfer, Type: Feature, Value:
> > 208.000000
>...
2006 Nov 11
1
Help with newhidups subdriver for Dynex UPS
...Feature, Value: 2.000000
Path: UPS.PowerSummary.iManufacturer, Type: Feature, Value: 3.000000
Path: UPS.Input.ConfigVoltage, Type: Feature, Value: 120.000000
Path: UPS.Input.Voltage, Type: Feature, Value: 120.000000
Path: UPS.Input.LowVoltageTransfer, Type: Feature, Value: 90.000000
Path: UPS.Input.HighVoltageTransfer, Type: Feature, Value: 140.000000
Path: UPS.Output.Voltage, Type: Feature, Value: 120.000000
Path: UPS.Output.PercentLoad, Type: Feature, Value: 92.000000
Path: UPS.Output.Test, Type: Feature, Value: 1.000000
Path: UPS.Output.DelayBeforeShutdown, Type: Feature, Value: -1.000000
Path: UPS.Output.D...
2018 Jul 26
5
Adding drivers to NUT?
Dear Daniele,
nice to meet you, I'm a collegue of Gabriele.
The problem with "blazer_usb" driver ("blazer_ser" works correctly) is related to the following commands:
- "F" and "I": when the KRAULER subdriver check these UPS answers it uses wrong constants to check the lenght of the received packets, so these commands are considered as "not
2019 Jan 28
0
Just an interesting data point [CyberPower SNMP/USB]
...tracking what you mean by 'scaled to the
> transfer voltage range' though. Could you clarify?
>
The "output.voltage" column in the quoted portion at the link is clipped/scaled to the range 136.0 to 142.0, which happens to be the range of possible settings for the USB HID HighVoltageTransfer voltage (NUT variable: input.transfer.high):
https://alioth-lists.debian.net/pipermail/nut-upsuser/2017-June/010685.html
2014 Mar 24
2
Incorrect Values From usbhid-ups
...0x0f, Offset: 0, Size: 16, Value: 119
0.263575 Path: UPS.Input.LowVoltageTransfer, Type: Feature,
ReportID: 0x10, Offset: 0, Size: 16, Value: 88
0.263585 Path: UPS.Input.LowVoltageTransfer, Type: Input,
ReportID: 0x10, Offset: 0, Size: 16, Value: 88
0.263593 Path: UPS.Input.HighVoltageTransfer, Type: Feature,
ReportID: 0x10, Offset: 16, Size: 16, Value: 139
0.263601 Path: UPS.Input.HighVoltageTransfer, Type: Input,
ReportID: 0x10, Offset: 16, Size: 16, Value: 139
0.263718 Path: UPS.Output.Voltage, Type: Feature, ReportID:
0x12, Offset: 0, Size: 16, Value: 136
0.2638...
2005 Oct 02
3
more on 2.0.3-pre
Gentlemen,
I have now had a chance to run some initial tests of my changes to
apc-hid.c of the current development tree. Running newhipups and
inspecting the -DDDD output seems to indicate that with the fix below
everything seems to work as expected. However, I have not yet shut
my system in order to take the UPS out of action so that I can do my
various tests with a lightbulb load. I still hope
2007 Jan 26
1
newhidups output for Geek Squad GS1285U
...Feature, Value: 2.000000
Path: UPS.PowerSummary.iManufacturer, Type: Feature, Value: 3.000000
Path: UPS.Input.ConfigVoltage, Type: Feature, Value: 120.000000
Path: UPS.Input.Voltage, Type: Feature, Value: 123.000000
Path: UPS.Input.LowVoltageTransfer, Type: Feature, Value: 90.000000
Path: UPS.Input.HighVoltageTransfer, Type: Feature, Value: 140.000000
Path: UPS.Output.Voltage, Type: Feature, Value: 123.000000
Path: UPS.Output.PercentLoad, Type: Feature, Value: 0.000000
Path: UPS.Output.Test, Type: Feature, Value: 1.000000
Path: UPS.Output.DelayBeforeShutdown, Type: Feature, Value: -60.000000
Path: UPS.Output.D...
2016 Dec 03
2
Problem installing NUT on 16.04
...0x0f,
Offset: 0, Size: 16, Value: 129
0.133228 Path: UPS.Input.LowVoltageTransfer, Type: Feature,
ReportID: 0x10, Offset: 0, Size: 16, Value: 88
0.133233 Path: UPS.Input.LowVoltageTransfer, Type: Input,
ReportID: 0x10, Offset: 0, Size: 16, Value: 88
0.133238 Path: UPS.Input.HighVoltageTransfer, Type: Feature,
ReportID: 0x10, Offset: 16, Size: 16, Value: 139
0.133242 Path: UPS.Input.HighVoltageTransfer, Type: Input,
ReportID: 0x10, Offset: 16, Size: 16, Value: 139
0.133339 Path: UPS.Output.Voltage, Type: Feature, ReportID: 0x12,
Offset: 0, Size: 16, Value: 137
0.133...
2006 Feb 10
1
newhidups capture - Atlantis-Land HID UPS
Hello Charles!
As promised, I just checked out the CVS and recompiled everything. In
the attached .txt is what is coming out from my UPS. I am wondering
about all those zeroes.
Also, this morning I plan to connect the UPS to a Win box running the
monitoring program supplied with the UPS (UPSilon2000) and a USB sniffer
program. If you have any suggestions on what to look for in the data,
2005 Jul 26
1
Some newhidups questions
...bytes) => 30 78 == 120
UPS.APC860018.ConfigVoltage (2 bytes) => 31 74 == 116
UPS.APC860018.Voltage (2 bytes) => 32 58 == 88
UPS.APC860018.LowVoltageTransfer (2 bytes) => 33 8B == 139
UPS.APC860018.HighVoltageTransfer (2 bytes) => 34 B1 == 177
UPS.APC860018.APC860024 (2 bytes) => 35 02 == 2
UPS.APC860018.APC860061 (2 bytes) => 36 00 == 0
UPS.APC860052.APCGeneralCollection (2 bytes) => 40 00 == 0
UPS.APC86...
2020 Oct 21
1
Can't get CyberPower UPS to work with Raspberry Pi 4
...ReportID: 0x0f, Offset:
0, Size: 16, Value: 120
0.035409 Path: UPS.Output.LowVoltageTransfer, Type: Feature, ReportID:
0x10, Offset: 0, Size: 16, Value: 100
0.035450 Path: UPS.Output.LowVoltageTransfer, Type: Input, ReportID:
0x10, Offset: 0, Size: 16, Value: 100
0.035487 Path: UPS.Output.HighVoltageTransfer, Type: Feature, ReportID:
0x10, Offset: 16, Size: 16, Value: 139
0.035523 Path: UPS.Output.HighVoltageTransfer, Type: Input, ReportID:
0x10, Offset: 16, Size: 16, Value: 139
0.036156 Path: UPS.Output.Voltage, Type: Feature, ReportID: 0x12,
Offset: 0, Size: 16, Value: 136
0.036904 Path: U...
2019 Jun 11
2
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...D: 0x30, Offset: 0, Size: 8, Value: 230
> 0.072912 Path: UPS.Input.Voltage, Type: Feature, ReportID: 0x31, Offset: 0, Size: 16, Value: 235
> 0.073536 Path: UPS.Input.LowVoltageTransfer, Type: Feature, ReportID: 0x32, Offset: 0, Size: 16, Value: 176
> 0.074160 Path: UPS.Input.HighVoltageTransfer, Type: Feature, ReportID: 0x33, Offset: 0, Size: 16, Value: 282
> 0.074783 Path: UPS.Input.ff860024, Type: Feature, ReportID: 0x34, Offset: 0, Size: 16, Value: 128
> 0.075399 Path: UPS.Input.APCSensitivity, Type: Feature, ReportID: 0x35, Offset: 0, Size: 8, Value: 1
> 0.0760...
2019 Jun 11
0
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...Offset: 0, Size: 8, Value: 230
>> 0.072912 Path: UPS.Input.Voltage, Type: Feature, ReportID: 0x31, Offset: 0, Size: 16, Value: 235
>> 0.073536 Path: UPS.Input.LowVoltageTransfer, Type: Feature, ReportID: 0x32, Offset: 0, Size: 16, Value: 176
>> 0.074160 Path: UPS.Input.HighVoltageTransfer, Type: Feature, ReportID: 0x33, Offset: 0, Size: 16, Value: 282
>> 0.074783 Path: UPS.Input.ff860024, Type: Feature, ReportID: 0x34, Offset: 0, Size: 16, Value: 128
>> 0.075399 Path: UPS.Input.APCSensitivity, Type: Feature, ReportID: 0x35, Offset: 0, Size: 8, Value: 1
>>...