search for: group_by_prio

Displaying 7 results from an estimated 7 matches for "group_by_prio".

2017 Jan 31
1
multipath show config different in CentOS 7?
...for my IBM/1814 storage array luns, then I put something like this in multipath.conf devices { device { vendor "IBM" product "^1814" product_blacklist "Universal Xport" path_grouping_policy "group_by_prio" path_checker "rdac" features "0" hardware_handler "1 rdac" prio "rdac" failback immediate rr_weight "uniform" no_path_retry "1...
2015 Apr 14
1
HBA enumeration and multipath configuration
...ons, etc. This messes up our multipath filtering for weightedpath priority settings. From /etc/multipath.conf: defaults { user_friendly_names no find_multipaths yes prio weightedpath prio_args "hbtl 0:.:.:.* 1 [1-9]:.:.:.* 10" path_grouping_policy group_by_prio path_selector "service-time 0" failback immediate polling_interval 5 no_path_retry 12 } The setting for prio_args fails to set the correct path map topology and priority against an HBA as I can't predict what HBA is what. Consistently iSCSI claims the...
2013 Sep 18
3
multipathing XCP 1.6
Hello, I hope to be in the right list. my question is the following. I can''t seem to get multipathing configure on XCP 1.6. In XenCenter I was able to enable "Multipath" however, in the LUN under general tab I see " multipath 1 of 1 active", the the CLI I do the following command xe --m node session it list only one session. Can someone help me please? Thanks in
2015 Mar 05
1
Cannot remount drive after lost iSCSI connection
The most recent message is: [3108269.919256] sd 2:0:1:0: timing out command, waited 1080s [3108269.919528] sd 2:0:1:0: [sdb] Unhandled error code [3108269.919535] sd 2:0:1:0: [sdb] Result: hostbyte=DID_OK driverbyte=DRIVER_OK [3108269.919540] sd 2:0:1:0: [sdb] CDB: Read(10): 28 00 00 01 21 47 00 00 08 00 [3108269.919586] EXT4-fs error (device sdb1): ext4_find_entry: reading directory #2 offset 0
2009 Sep 27
0
SUMMARY : multipath using defaults rather than multipath.conf contents for some devices (?) - why ?
...;HSV1[01]1|HSV2[01]0|HSV300|HSV4[05]0" getuid_callout "/sbin/scsi_id -g -u -s /block/%n" prio_callout "/sbin/mpath_prio_alua /dev/%n" hardware_handler "0" path_selector "round-robin 0" path_grouping_policy group_by_prio failback immediate rr_weight uniform no_path_retry 18 rr_min_io 100 path_checker tur } - but our actual multipathing as shown by multipath -ll , and multipath -ll -v 3 looks as though for the HSV400 it is using the defaults rather t...
2009 Sep 17
1
multipath using defaults rather than multipath.conf contents for some devices (?) - why ?
...;HSV1[01]1|HSV2[01]0|HSV300|HSV4[05]0" getuid_callout "/sbin/scsi_id -g -u -s /block/%n" prio_callout "/sbin/mpath_prio_alua /dev/%n" hardware_handler "0" path_selector "round-robin 0" path_grouping_policy group_by_prio failback immediate rr_weight uniform no_path_retry 18 rr_min_io 100 path_checker tur } - but our actual multipathing as shown by multipath -ll , and multipath -ll -v 3 looks as though for the HSV400 it is using the defaults rather th...
2010 May 27
2
Multipathing with Sun 7310
Dear list, we have a relatively new Sun Storage 7310, where we connect CentOS 5.5 Servers (IBM LS21/LS41 Blades) via Brocade Switches, 4GBit FC. The Blades boot from SAN via qla2xxx, and have no harddisks at all. We want them to use multipathing from the very beginning, so /boot and / are already seen by multipathd. Problem is, that the Sun 7310 has two storage heads which run in