Displaying 10 results from an estimated 10 matches for "get_data_phoenix".
2010 Oct 03
1
You lost support of Belkin Universal UPS F6C1100-UNV
...or
- Product: USB to Serial
- Serial Number: unknown
- Bus: 003
Trying to match device
Device matches
none (-110)
DTR=1, RTS=0
Starting UPS detection process...
Asking for UPS information [I]...
none (-110)
I => FAILED [short read]
I detail: (1 bytes) => 49
Asking for UPS status [Q1]...
ok
get_data_phoenix: got so far [(121.3 1]
get_data_phoenix: (8 bytes) => 28 31 32 31 2e 33 20 31
ok
get_data_phoenix: got so far [(121.3 121.6 121]
get_data_phoenix: (16 bytes) => 28 31 32 31 2e 33 20 31 32 31 2e 36 20 31
32 31
ok
get_data_phoenix: got so far [(121.3 121.6 121.6 017 5]
get_data_phoenix: (24...
2009 Jul 19
1
Problem with nut 2.4.1 & Ippon 2000 Smart power on FreeBSD
...USB to Serial
- Serial Number: unknown
- Bus: /dev/usb1
Trying to match device
Device matches
DTR=1, RTS=0
Starting UPS detection process...
Asking for UPS information [I]...
I => FAILED [short read]
I detail: (1 bytes) => 49
Asking for UPS status [Q1]...
0]t_data_phoenix: got so far [001001
get_data_phoenix: (8 bytes) => 30 30 31 30 30 31 0d 30
0(222.8 2]hoenix: got so far [001001
get_data_phoenix: (16 bytes) => 30 30 31 30 30 31 0d 30 28 32 32 32 2e 38
20 32
0(222.8 222.8 222]got so far [001001
get_data_phoenix: (24 bytes) => 30 30 31 30 30 31 0d 30 28 32 32 32 2e 38
20 32 32 32 2e 38 20 3...
2009 Feb 19
2
megatec_usb vs Mustek NetGuard / Ippon SmartWinner problem
...ProductID: 0003
- Manufacturer: OMRON
- Product: USB UPS
- Serial Number: unknown
- Bus: 002
Trying to match device
Device matches
DTR=1, RTS=0
Starting UPS detection process...
Asking for UPS information [I]...
I => FAILED [short read]
I detail: (1 bytes) => 49
Asking for UPS status [Q1]...
get_data_phoenix: got so far [(213.8 2]
get_data_phoenix: (8 bytes) => 28 32 31 33 2e 38 20 32
3]t_data_phoenix: got so far [(213.8 2001001
get_data_phoenix: (16 bytes) => 28 32 31 33 2e 38 20 32 30 30 31 30 30 31
0d 33
3.8 031 5]hoenix: got so far [(213.8 2001001
get_data_phoenix: (24 bytes) => 28 32 31...
2009 Dec 06
1
Integra Tech (ePlus) support
...Asking for UPS information [I]...
I => FAILED [short read]
I detail: (1 bytes) => 49
Asking for UPS status [Q1]...
]et_data_phoenix: got so far [Q1
get_data_phoenix: (8 bytes) => 51 31 0d 00 00 00 00 00
]et_data_phoenix: got so far [Q1
get_data_phoenix: (16 bytes) => 51 31 0d 00 00 00 00 00 00 00 00 00 00 00
00 00
]et_data_phoenix: got so far [Q1...
2008 Dec 05
2
Mustek PowerMust 848
..., RTS=0
> send_to_all: SETINFO driver.version.internal "1.5.18"
> Starting UPS detection process...
> Asking for UPS information [I]...
> I => FAILED [short read]
> I detail: (1 bytes) => 49
> Asking for UPS status [Q1]...
> 00]_data_phoenix: got so far [Q1
> get_data_phoenix: (8 bytes) => 51 31 0d 2e 30 0d 30 30
> Q1 => FAILED [short read]
> Q1 detail: (2 bytes) => 51 31
> Asking for UPS status [Q1]...
> 00]_data_phoenix: got so far [Q1
> get_data_phoenix: (8 bytes) => 51 31 0d 2e 30 0d 30 30
> Q1 => FAILED [short read]
> Q1 detail:...
2008 Dec 05
2
Mustek PowerMust 848
..., RTS=0
> send_to_all: SETINFO driver.version.internal "1.5.18"
> Starting UPS detection process...
> Asking for UPS information [I]...
> I => FAILED [short read]
> I detail: (1 bytes) => 49
> Asking for UPS status [Q1]...
> 00]_data_phoenix: got so far [Q1
> get_data_phoenix: (8 bytes) => 51 31 0d 2e 30 0d 30 30
> Q1 => FAILED [short read]
> Q1 detail: (2 bytes) => 51 31
> Asking for UPS status [Q1]...
> 00]_data_phoenix: got so far [Q1
> get_data_phoenix: (8 bytes) => 51 31 0d 2e 30 0d 30 30
> Q1 => FAILED [short read]
> Q1 detail:...
2008 May 08
12
Maruson power net 1500 support?
I recently took over maintenance of a linux computer which is drawing
power from a "Maruson Power Net 1500" UPS. However, there is currently
no monitoring or control of the UPS by this (or any other) computer.
Can nut control this device? There are serial, usb, and EPO connectors
on the back of the unit. (There may be a manual but I'm going to have
to hunt for it.)
Thanks,
David
2008 Dec 19
1
megatec_usb: Ippon BackComfoPro (06da:0003 Phoenixtec Power)
...get_line only returns the received characters
up to the first "\r" (hex 0d) back to run_query.
The problem is, the data returned by my UPS is for some reason
sprinkled with these "\r" characters right in the middle of useful
data. Here is a hex dump of what is being returned by get_data_phoenix:
28 32 31 37 2e 30 20 32 30 30 31 30 30 31 0d 37 2e 30 20 30 32 32 20 35
30 2e 31 20 31 33 2e 38 20 32 35 2e 30 20 30 30 30 30 31 30 30 31 0d 37
2e 30 20 30 32 32 20 35 30 2e 31 20 31 33 2e 38 30 2e 31 20 31 33 2e 38
As you can see, there is an "\r" after just the first 14 characters,
b...
2017 Apr 28
3
Powercom BNT-2000AP(USB)
Hello all!
Some days ago we received new UPS?Powercom BNT-2000AP with USB interface to replace an old staff and I've spent four last days trying to connect it with NUT. I have a FreeBSD 8.4 box with NUT 2.7.2.
# dmesg|grep -i powercom
ugen0.3: <POWERCOM Co.,LTD> at usbus0
uhid0: <POWERCOM Co.,LTD HID UPS Battery, class 0/0, rev 1.10/0.01, addr 3> on usbus0
uhid0: <POWERCOM
2010 Jun 30
1
megatec_usb.c modification for UPSONIC PROFFICE 650 USB
Hi Heinz,
2010/5/30 heinz
> Thank you for your nut-2.4.3 system. I had big troubles getting it to work
> with the UPSONIC PROFFICE 650 UPS in USB mode.
>
> I had to rewrite the get_data_phoenix() function in drivers/megatec_usb.c
> file.
> It now appears to be working correctly. I have attached the source of the
> modified function in case you might want to add it to a future version.
>
first, thanks for your report. Though it's always better to report to the