2017 Oct 29
2
Virtio BoF minutes from KVM Forum 2017
Virtio BoF minutes KVM Forum 2017
Attendees: Amnon Ilan, Maxime Coqueline, Vlad Yasevich, Malcolm Crossley,
David Vrabel, Ilya Lesokhin, Cunming Lian, Jens Freimann
Topics: packed ring layout with respect to hardware implementations
References:
https://lists.oasis-open.org/archives/virtio-dev/201702/msg00010.html
https://lists.oasis-open.org/archives/virtio-dev/201709/msg00013.html
Malcolm
2017 Oct 29
2
Virtio BoF minutes from KVM Forum 2017
Virtio BoF minutes KVM Forum 2017
Attendees: Amnon Ilan, Maxime Coqueline, Vlad Yasevich, Malcolm Crossley,
David Vrabel, Ilya Lesokhin, Cunming Lian, Jens Freimann
Topics: packed ring layout with respect to hardware implementations
References:
https://lists.oasis-open.org/archives/virtio-dev/201702/msg00010.html
https://lists.oasis-open.org/archives/virtio-dev/201709/msg00013.html
Malcolm
2017 Nov 01
0
Virtio BoF minutes from KVM Forum 2017
On Sun, Oct 29, 2017 at 01:52:25PM +0100, Jens Freimann wrote:
> Ilya: - you might have more completions than descriptors available
> - partial descriptor chains are a problem for hardware because you might have
> to read a bunch of conscriptors twice - how would you do deal with a big
> buffer that cointains a large number of
> small packets with respect to completions?
> - is
1999 Aug 04
0
Bad NT performance on large Samba directories (PR#19452)
...and stat call's and that's what slows
> down the Samba server extremely, using 100% of its CPU time.
> I also watched the network activity using 'snoop' during the delete
> action of the NT-client and what I discovered was, that all the
> information the Samba server is gattering with all these system calls,
> is not going to the NT-client all the time.
>
> Who needs all this information and why does the Samba server shows this
> behavior????
Unfortunately the Windows client is asking for this
information, and the Samba server is trying to follow
the requests...
2010 Jul 08
1
Prefered Method for UPS?
...ot; identify it self as USB serial device
using /dev/ttxyUSBxx
All infos from the DS1780 and current sensors are currently stored in a
multi-dimensional Array.
So, currently I realy do not know HOW I schould send the infos to NUT.
Can you tell me what the prefered method is for NUT?
The MCU is gattering the infos like:
1) own identification (Maxim DS28CZ04)
0000 -> "12345678" # serial number \
0001 -> "24V DC modular ATX # real name of the modue | I?C EEPROM
0002 -> "electronica at tdnet" # Vendor Real Name |...