2023 Jan 17
1
PR to test for users of Qx devices (blazer and nutdrv_qx)
...alue as 2.7.4.
the battery.charge report of 10kv and 3kv are fine. but 2kv is wrong.
with 2.7.4 the 2kv battery.charge is reporting 100. but the new code
is reporting 67. details below:
10KV:
./nutdrv_qx -a ftups -d1
Network UPS Tools - Generic Q* USB/Serial driver 0.33
(Windows-v2.8.0-alpha3-1252-g757813e)
USB communication driver (libusb 0.1) 0.44
Using protocol: Voltronic 0.07
battery_number: 20
battery_number, settable range: 1..9
bypass_alarm: enabled
battery_alarm: enabled
bypass_when_off: disabled
alarm_control: enabled
converter_mode: disabled
eco_mode: disabled
battery_open_status_check: ena...
2023 Jan 17
1
PR to test for users of Qx devices (blazer and nutdrv_qx)
...alue as 2.7.4.
the battery.charge report of 10kv and 3kv are fine. but 2kv is wrong.
with 2.7.4 the 2kv battery.charge is reporting 100. but the new code
is reporting 67. details below:
10KV:
./nutdrv_qx -a ftups -d1
Network UPS Tools - Generic Q* USB/Serial driver 0.33
(Windows-v2.8.0-alpha3-1252-g757813e)
USB communication driver (libusb 0.1) 0.44
Using protocol: Voltronic 0.07
battery_number: 20
battery_number, settable range: 1..9
bypass_alarm: enabled
battery_alarm: enabled
bypass_when_off: disabled
alarm_control: enabled
converter_mode: disabled
eco_mode: disabled
battery_open_status_check: ena...
2023 Jan 15
1
PR to test for users of Qx devices (blazer and nutdrv_qx)
Cheers,
One PR waiting to get into 2.8.1 release timeframe is
https://github.com/networkupstools/nut/pull/1652 stemming from issue
https://github.com/networkupstools/nut/issues/1279
The gist of it is that "battery.voltage" and "battery.charge" were not
always reported correctly with nutdrv-qx driver (might be handled better by
blazer drivers though), and the overrides