2020 Jan 14
2
Tripp Lite SMART1500LCD will not stay shut down when power is disconnected
Your suggestion of rebuilding the driver fixed the issue of the UPS turning back during a power failure. Now the UPS shuts down the clients, then powers off appropriately. If power returns it turns back on also. The only bug is if power returns before the UPS has turned the load off. In that case the UPS will remain off until it is manually turned on. This might just be a limitation of this
2020 Jan 14
0
Tripp Lite SMART1500LCD will not stay shut down when power is disconnected
...ce.mfr: Tripp Lite device.model: Tripp Lite UPS device.type: ups driver.name: usbhid-ups driver.parameter.offdelay: 10 driver.parameter.ondelay: 50 driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.parameter.synchronous: no driver.version: 2.7.4-476-g6b9971a7 driver.version.data: TrippLite HID 0.82 driver.version.internal: 0.42 input.frequency: 60.0 input.voltage: 118.2 input.voltage.nominal: 120 output.frequency.nominal: 60 output.voltage.nominal: 120 ups.beeper.status: disabled ups.delay.shutdown: 10 ups.mfr: Tripp Lite ups.model: Tripp Lite UPS ups...
2020 Jan 14
2
[EXTERNAL] Re: Tripp Lite SMART1500LCD will not stay shut down when power is disconnected
...vice.mfr: Tripp Lite device.model: Tripp Lite UPS device.type: ups driver.name: usbhid-ups driver.parameter.offdelay: 10 driver.parameter.ondelay: 50 driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.parameter.synchronous: no driver.version: 2.7.4-476-g6b9971a7 driver.version.data: TrippLite HID 0.82 driver.version.internal: 0.42 input.frequency: 60.0 input.voltage: 118.2 input.voltage.nominal: 120 output.frequency.nominal: 60 output.voltage.nominal: 120 ups.beeper.status: disabled ups.delay.shutdown: 10 ups.mfr: Tripp Lite ups.model: Tripp Lite UPS ups.p...