2007 Jul 11
9
NFS cache flush tester
http://dovecot.org/tools/nfstest.c
I wrote a test utility that tests different ways to flush NFS attribute
cache and data cache. Please test in your NFS setup and show me the
results, so I can make Dovecot v1.1 works well with NFS.
Run the test several times (3 should be enough) to make sure the output
stays the same, because the attribute cache flushes might incorrectly
say "OK". And
2008 Oct 07
2
1.1.4 and trouble over NFS
Hello, I have some trouble with the current setup (it's a testing
environment):
2 server with Dovecot 1.1.4 from source (OS Debian testing 2.6.26)
(name: "exim" and "exim2")
1 NFS server (OS Debian testing 2.6.26)
I use NFS v.4, indexes shared over NFS. The relavant part of Dovecot
configuration:
dotlock_use_excl = yes
mail_nfs_storage = yes
mail_nfs_index = yes
2019 Apr 11
4
[PATCH v5 1/6] libnvdimm: nd_region flush callback support
On Tue, Apr 9, 2019 at 9:09 PM Pankaj Gupta <pagupta at redhat.com> wrote:
>
> This patch adds functionality to perform flush from guest
> to host over VIRTIO. We are registering a callback based
> on 'nd_region' type. virtio_pmem driver requires this special
> flush function. For rest of the region types we are registering
> existing flush function. Report error
2019 Apr 11
4
[PATCH v5 1/6] libnvdimm: nd_region flush callback support
On Tue, Apr 9, 2019 at 9:09 PM Pankaj Gupta <pagupta at redhat.com> wrote:
>
> This patch adds functionality to perform flush from guest
> to host over VIRTIO. We are registering a callback based
> on 'nd_region' type. virtio_pmem driver requires this special
> flush function. For rest of the region types we are registering
> existing flush function. Report error
2008 Jun 11
1
xen migrate never ends
Hello, i have two xen hosts servers configured to support migration of
domus, but when i try to migrate, the command never ends, i can see on
the remote server the machine with xm list but the machine is not
accesible, and on the own server i see migrating-{machine_name} and i
have access to it.
Every server have one nic, with public ip (that is using with xenbr0),
and i have a virbr0 configured
2023 Mar 28
1
[PATCH v6 04/11] vhost: take worker or vq instead of dev for flushing
This patch has the core work flush function take a worker. When we
support multiple workers we can then flush each worker during device
removal, stoppage, etc.
Signed-off-by: Mike Christie <michael.christie at oracle.com>
---
drivers/vhost/vhost.c | 24 +++++++++++++++---------
1 file changed, 15 insertions(+), 9 deletions(-)
diff --git a/drivers/vhost/vhost.c b/drivers/vhost/vhost.c
2011 Jan 11
6
[RFC PATCH 0/2] ASID: Flush by ASID
Future AMD SVM supports a new feature called flush by ASID. The idea is to
allow CPU to flush TLBs associated with the ASID assigned to guest VM. So
hypervisor doesn''t have to reassign a new ASID in order to flush guest''s
VCPU. Please review it.
Thanks,
Wei
Signed-off-by: Wei Huang <wei.huang2@amd.com>
Signed-off-by: Wei Wang <wei.wang2@amd.com>
--
Advanced Micro
2012 Dec 18
1
[PATCH] Btrfs: set flushing if we're limited flushing
We still need to say we''re flushing if we''re limit flushing to keep somebody
from coming in and stealing our reservation. Thanks,
Signed-off-by: Josef Bacik <jbacik@fusionio.com>
---
fs/btrfs/extent-tree.c | 2 +-
1 files changed, 1 insertions(+), 1 deletions(-)
diff --git a/fs/btrfs/extent-tree.c b/fs/btrfs/extent-tree.c
index ad8786b..721efb8 100644
---
2019 Apr 11
1
[Qemu-devel] [PATCH v5 1/6] libnvdimm: nd_region flush callback support
On Thu, Apr 11, 2019 at 9:02 AM Pankaj Gupta <pagupta at redhat.com> wrote:
>
>
>
> > >
> > > This patch adds functionality to perform flush from guest
> > > to host over VIRTIO. We are registering a callback based
> > > on 'nd_region' type. virtio_pmem driver requires this special
> > > flush function. For rest of the region
2009 Jun 02
3
search without flush.
Hi,
Is it possible to perform a search without flushing the index? I've got
an application that updates the index every 4 hours but I need to be
able to search the new data fairly quickly after the index is updated.
The problem revolves around the fact that the update is often much less
than 10 000 documents so it isn't being flushed until quite a bit
latter. I realise I can do a flush
2008 May 05
3
troubles with R CMD check and examples under Ubuntu gutsy
Dear listers,
I was used to package pgirmess under Windows with everything OK, but,
for the first time, I had a trial this afternoon on Ubuntu 7.10 gutsy (I
have a double boot computer and work more and more under unix) and R
2.7.0. Everything went OK except this:
sudo R CMD check pgirmess
.....
* checking examples ... ERROR
Running examples in 'pgirmess-Ex.R' failed.
The error most
2004 Jun 01
1
Searching without flush?
Hi,
I am using the Xapian-0.8.0 snapshot from 15-Apr-2004 02:14, and I am
using the same Xapian::WritableDatabase instance for indexing and searching.
Currently each search causes a database flush, which is slow.
How can I avoid this flush?
It seems that I have to modify Xapian to either
- search only the already flushed data (eventually missing some hits)
or
- search the un-flushed data, too.
2014 Nov 02
2
Re: KVM incremental backup using CBT
> > A quick google search found this:
> > http://callecalle.uach.cl/ovirt-engine/docs/manual/en_US/html/Technical_Gu
> > id e/QEMU_Guest_Agent_Overview.html
> >
> > Sadly, it didn't spell out the name of where you install hook scripts
> > into the guest. But this commit is pretty telling:
> >
2006 Apr 21
4
[Xen-ia64-devel] flush_tlb_mask and grant_table on ia64
Hi,
on IA64 flushing the whole TLB is very expensive: this is a cpu tlb flush and
clearing 16MB of memory (virtual tlb).
However, flushing an address range is rather cheap. Flushing an address range
on every processors is also cheap (no IPI).
Unfortunatly Xen common code flushes the whole TLB after unmapping grant
reference.
Currently, this is not done on IA64 because domain_dirty_cpumask
2008 May 27
3
[PATCH] VT-d: IOTLB flush fixups
On map: only flush when old PTE was valid or invalid PTE may be cached.
On unmap: always flush old entry, but skip flush for unaffected IOMMUs.
Signed-off-by: Espen Skoglund <espen.skoglund@netronome.com>
--
iommu.c | 17 +++++++++++------
1 file changed, 11 insertions(+), 6 deletions(-)
--
diff -r 8187fd8113f9 xen/drivers/passthrough/vtd/iommu.c
---
2019 Apr 11
0
[Qemu-devel] [PATCH v5 1/6] libnvdimm: nd_region flush callback support
> >
> > This patch adds functionality to perform flush from guest
> > to host over VIRTIO. We are registering a callback based
> > on 'nd_region' type. virtio_pmem driver requires this special
> > flush function. For rest of the region types we are registering
> > existing flush function. Report error returned by host fsync
> > failure to
2019 Mar 12
9
[RFC PATCH V2 0/5] vhost: accelerate metadata access through vmap()
On Tue, Mar 12, 2019 at 10:59:09AM +0800, Jason Wang wrote:
>
> On 2019/3/12 ??2:14, David Miller wrote:
> > From: "Michael S. Tsirkin" <mst at redhat.com>
> > Date: Mon, 11 Mar 2019 09:59:28 -0400
> >
> > > On Mon, Mar 11, 2019 at 03:13:17PM +0800, Jason Wang wrote:
> > > > On 2019/3/8 ??10:12, Christoph Hellwig wrote:
> > >
2019 Mar 12
9
[RFC PATCH V2 0/5] vhost: accelerate metadata access through vmap()
On Tue, Mar 12, 2019 at 10:59:09AM +0800, Jason Wang wrote:
>
> On 2019/3/12 ??2:14, David Miller wrote:
> > From: "Michael S. Tsirkin" <mst at redhat.com>
> > Date: Mon, 11 Mar 2019 09:59:28 -0400
> >
> > > On Mon, Mar 11, 2019 at 03:13:17PM +0800, Jason Wang wrote:
> > > > On 2019/3/8 ??10:12, Christoph Hellwig wrote:
> > >
2015 Aug 13
2
SmallString + raw_svector_ostream combination should be more efficient
Ok, one more issue. I've removed the no-op resync() method and now getting
rid of numerous raw_ostream::flush() calls. These were required before but
now will never do anything but will waste runtime discovering that.
To find raw_svector_ostream::flush() calls speficially I locally shadowed
raw_ostream:flush() with a deleted flush():
class raw_svector_ostream {
...
public:
...
void flush()
2020 Mar 17
0
[nbdkit PATCH 4/4] RFC tests: Add test to cover unusual .can_flush return
We want some testsuite coverage of handling non-1 .can_flush values.
The only in-tree plugin with this property is nbd-standalone, but it
doesn't get frequently tested, not to mention that the next patch will
change it to work with older nbdkit.
Signed-off-by: Eric Blake <eblake@redhat.com>
---
work in progress: currently compiles but fails during test; posting it
now to show my